Theoretical risk assessment of magnesium alloys as degradable biomedical implants

被引:63
|
作者
Yuen, C. K. [1 ]
Ip, W. Y. [1 ,2 ]
机构
[1] Univ Hong Kong, Dept Orthopaed & Traumatol, LKS Fac Med, Hong Kong, Hong Kong, Peoples R China
[2] Queen Mary Hosp, Dept Orthopaed & Traumatol, Hong Kong, Hong Kong, Peoples R China
关键词
Aluminum; Toxicology; Risk assessment; Metallic implant; Degradable; ALZHEIMERS-DISEASE; ALUMINUM; PHARMACOLOGY; TOXICOLOGY; WATER; HYPERMAGNESEMIA; ZIRCONIUM; BONE;
D O I
10.1016/j.actbio.2009.11.036
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The theoretical tolerable implant masses for ten magnesium alloys as degradable biomedical implant materials are evaluated in this study. Dose-response assessment is conducted using toxicological data from authoritative public health agencies such as the US Agency for Toxic Substances and Disease Registry and the USEPA Integrated Risk Information System, and assuming 1 year of even corrosion. Uncertainty factors adopted by the agencies are used. The tolerable limits corresponding to various component elements in an alloy are considered separately, and the lowest tolerable limit is selected as the tolerable limit of the alloy. The results show that aluminum is usually the component element with the lowest tolerance, and the tolerable mass for Al-containing magnesium alloys fall to around or below 1 g per person per year, while the limit for other magnesium alloys can well exceed 10 g. Deficits in the toxicological data of some component elements are noted. This study illustrates that toxicological calculations should be taken into consideration when developing novel degradable metallic implants. (C) 2009 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1808 / 1812
页数:5
相关论文
共 50 条
  • [21] Biomedical application of magnesium alloys
    Yamamoto, Akiko
    Keikinzoku/Journal of Japan Institute of Light Metals, 2008, 58 (11): : 570 - 576
  • [22] EVALUATION OF MAGNESIUM ALLOYS AS DEGRADABLE IMPLANT MATERIAL
    Evertz, F.
    Glasmacher, B.
    Kietzmann, M.
    Mueller, P. P.
    Hauser, H.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2010, 33 (07): : 468 - 469
  • [23] Magnesium alloys as a biomaterial for degradable craniofacial screws
    Henderson, Sarah E.
    Verdelis, Konstantinos
    Maiti, Spandan
    Pal, Siladitya
    Chung, William L.
    Chou, Da-Tren
    Kumta, Ptashant N.
    Almarza, Alejandro J.
    ACTA BIOMATERIALIA, 2014, 10 (05) : 2323 - 2332
  • [24] Strategies to improve the corrosion resistance of microarc oxidation (MAO) coated magnesium alloys for degradable implants: Prospects and challenges
    Narayanan, T. S. N. Sankara
    Park, Il Song
    Lee, Min Ho
    PROGRESS IN MATERIALS SCIENCE, 2014, 60 : 1 - 71
  • [25] Impact of degradable magnesium implants on osteocytes in single and triple cultures
    Bernhardt, Anne
    Helmholz, Heike
    Kilian, David
    Willumeit-Roemer, Regine
    Gelinsky, Michael
    BIOMATERIALS ADVANCES, 2022, 134
  • [26] Ultra-Fine Grained Degradable Magnesium for Biomedical Applications
    Ge Qiang
    Mostaed, Ehsan
    Zanella, Caterina
    Yu Zhentao
    Vedani, Maurizio
    RARE METAL MATERIALS AND ENGINEERING, 2014, 43 (11) : 2561 - 2566
  • [28] Risk Assessment of Corrosion Inhibitors of Magnesium and Its Alloys
    Winston, J. Arockia
    Hynes, N. Rajesh Jesudoss
    Sankaranarayanan, R.
    3RD INTERNATIONAL CONFERENCE ON CONDENSED MATTER & APPLIED PHYSICS (ICC-2019), 2020, 2220
  • [29] Assessment of magnesium calcium alloys improved by rare earths addition for medical implants
    Savin, A.
    Novy, F.
    Craus, M. L.
    Iftimie, N.
    Steigmann, R.
    Istrate, B.
    Munteanu, C.
    MODTECH INTERNATIONAL CONFERENCE - MODERN TECHNOLOGIES IN INDUSTRIAL ENGINEERING VIII, 2020, 916
  • [30] Biomedical coatings on magnesium alloys - A review
    Hornberger, H.
    Virtanen, S.
    Boccaccini, A. R.
    ACTA BIOMATERIALIA, 2012, 8 (07) : 2442 - 2455