Microinjection of living adherent cells by using a semi-automatic microinjection system

被引:21
|
作者
Viigipuu, K [1 ]
Kallio, P [1 ]
机构
[1] Tampere Univ Technol, Inst Automat & Control, FIN-33101 Tampere, Finland
来源
关键词
adherent cells; capillary pressure microinjection; cell curvival rate; injection success rate; micromanipulator; penetration success rate; semi-automatic microinjection;
D O I
10.1177/026119290403200414
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Testing in vitro is an alternative to animal experimentation. The capillary pressure microinjection technique is a supporting technology for efficient in vitro testing. The main benefit of the technique is the possibility of injecting large molecules into a single living cell. The ultimate goal of the research discussed in this paper is to increase the cell survival rate in capillary pressure microinjection. A method to reliably evaluate cell survival rate is therefore needed. A three-phase evaluation process is presented in this paper. The first phase determines the success rate of the injection capillary to penetrate the cell membrane. The second phase studies the success rate of delivering the injection substance inside the cell, while the third phase studies cell survival after the microinjection. In addition to the three-phase evaluation process, this paper describes the initial results of penetration and injection tests performed by using a semi-automatic capillary pressure microinjection system developed by the research group. Three adherent cell lines, namely, retinal pigment epithelia] cells, MCF-7 human breast cancer cells and SH-SY5Y neuroblastoma cells, were used in the experiments. The results of the penetration tests show that the average success rate of penetrating the cell membrane using the micromanipulator was 87%. The goal of the injection tests was to demonstrate the successful microinjection of living cells and to study the injection success rate. Fluorescein dextran was injected into MCF-7 cells, and preliminary results showed an injection success rate of 49%. In the survival tests, the neuronal cells were microinjected with KCl. During long-term observation after the microinjection, the microinjected cells first decreased their adhesion to the plate, but later adhered to the bottom of the plate and even grew some dendrites. In the next phase of the study, more tests will be performed in order to obtain a statistically reliable value for the survival rate.
引用
收藏
页码:417 / 423
页数:7
相关论文
共 50 条
  • [41] Development of a semi-automatic system for pollen recognition
    Alain Boucher
    Pablo J. Hidalgo
    Monique Thonnat
    Jordina Belmonte
    Carmen Galan
    Pierre Bonton
    Régis Tomczak
    Aerobiologia, 2002, 18 (3-4) : 195 - 201
  • [42] A semi-automatic system for edge tracking with snakes
    Hoch, M
    Litwinowicz, PC
    VISUAL COMPUTER, 1996, 12 (02): : 75 - 83
  • [43] Semi-automatic control system for hydraulic shovel
    Araya, H
    Kagoshima, M
    AUTOMATION IN CONSTRUCTION, 2001, 10 (04) : 477 - 486
  • [44] A Semi-automatic System for Knowledge Base Population
    Goldstein-Stewart, Jade
    Winder, Ransom K.
    KNOWLEDGE DISCOVERY, KNOWLEDGE ENGINEERING AND KNOWLEDGE MANAGEMENT, 2011, 128 : 276 - +
  • [45] SEMI-AUTOMATIC SYSTEM FOR ACTIVATION ANALYSIS USING WWR NUCLEAR REACTOR
    LISOVSKII, IP
    SMAKHTIN, LA
    FILIPPOV.NV
    VOLGIN, VI
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1971, 8 (02): : 313 - +
  • [46] VACUUM SYSTEM FOR SEMI-AUTOMATIC DEGASSING OF SOLVENTS
    WIESENFELD, JR
    JAPAR, SM
    TALANTA, 1969, 16 (05) : 619 - +
  • [47] A Semi-Automatic System for Data Management and Cleaning
    Asghari, Mohsen
    Sierra-Sosa, Daniel
    Elmaghraby, Adel
    2018 IEEE INTERNATIONAL SYMPOSIUM ON SIGNAL PROCESSING AND INFORMATION TECHNOLOGY (ISSPIT), 2018, : 393 - 397
  • [48] A semi-automatic system for tagging specialized corpora
    Amrani, A
    Kodratoff, Y
    Matte-Tailliez, O
    ADVANCES IN KNOWLEDGE DISCOVERY AND DATA MINING, PROCEEDINGS, 2004, 3056 : 670 - 681
  • [49] Semi-automatic system for edge tracking with snakes
    Acad of Media Arts, Cologne, Germany
    Visual Comput, 2 (75-83):
  • [50] Research of semi-automatic humanoid robot system
    Luo, Zhong-Wen
    Zhu, Yong
    Ren, Zhi-Min
    Xu, Yin
    Yang, Lin-Quan
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2010, 42 (SUPPL. 2): : 127 - 130