Experimental investigation of rain-wind-induced vibration of cables in cable-stayed bridges and its mitigation

被引:136
|
作者
Gu, M [1 ]
Du, XQ [1 ]
机构
[1] Tongji Univ, State Key Lab Disaster Reduct Civil Engn, Shanghai 200092, Peoples R China
基金
中国国家自然科学基金;
关键词
cable-stayed bridge-; stay cable; rain-wind-induced vibration; wind tunnel test; mitigation;
D O I
10.1016/j.jweia.2004.09.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Rain-wind-induced vibration of cables in cable-staved bridges is presently a worldwide problem of great concern. Because it is sensitively influenced by many parameters. this peculiar phenomenon is difficult to be replicated in laboratory conditions; its mechanism has not been well explained yet. In this paper, the phenomenon of rain-wind-induced vibration of a cable model is successfully reproduced under actual rain conditions in a wind tunnel. The effects of several main factors, including the inclination angle, frequency and damping of the cable as well as the wind yaw angle, etc. on the characteristics of rain-wind-induced vibration are investigated in detail in the test. The countermeasures of double-spiral wires and dampers for the mitigation of the vibration are also experimentally studied. The results show that the size and twine direction and the pitch of the spiral wires twined on the surface of cables have great effects on the mitigation efficiency of rain-wind-induced vibration of cables. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:79 / 95
页数:17
相关论文
共 50 条
  • [21] Joint probability distribution model of wind-rain-induced vibration parameters of stay cables on cable-stayed bridges
    Wang, Xiuyong
    Jiang, Qianchao
    Sun, Hongxin
    Yu, Jianda
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2017, 50 (10): : 69 - 74
  • [22] Rain-wind induced vibrations of cables in cable stayed bridges
    Hikami, Y.
    Shiraishi, N.
    Journal of Wind Engineering and Industrial Aerodynamics, 1988, 29 pt 2 (1-3) : 409 - 418
  • [23] RAIN-WIND INDUCED VIBRATIONS OF CABLES IN CABLE STAYED BRIDGES
    HIKAMI, Y
    SHIRAISHI, N
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1988, 29 (1-3) : 409 - 418
  • [24] The application of MR damper in rain-wind-induced vibration reduction of stayed cable
    School of Mechanical Engineering, Tianjin University, Tianjin 300072, China
    Gongcheng Lixue/Engineering Mechanics, 2007, 24 (09): : 100 - 104
  • [25] Wind load, wind induced vibrations and control of cables of cable-stayed bridges
    Liu, Qing-Kuan
    Zheng, Yun-Fei
    Liu, Xiao-Bing
    Ma, Wen-Yong
    Gongcheng Lixue/Engineering Mechanics, 2015, 32 (09): : 1 - 8
  • [26] A New Method to Reduce Rain–Wind-Induced Vibration in Cable Sleeve of Cable-Stayed Bridges and Modeling in a Wind Tunnel
    Hani Baghi
    Ali Golsoorat Pahlaviani
    Mohammad Hasan Ramesht
    Jafar Asgari Marnani
    Arash Mirabdolah Lavasani
    Iranian Journal of Science and Technology, Transactions of Civil Engineering, 2023, 47 : 2287 - 2293
  • [27] Coupled vibration of cable-stayed bridges considering cables' interaction
    Liang D.
    Kang J.
    Zhao W.
    Liu J.
    1600, Chinese Vibration Engineering Society (39): : 125 - 131and147
  • [28] Simple model of rain-wind-induced vibrations of stayed cables
    Wilde, K
    Witkowski, W
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2003, 91 (07) : 873 - 891
  • [29] Analysis of cables in cable-stayed bridges
    Santos, I. C.
    Caetano, E. S.
    Brito, J. L. V.
    MAINTENANCE, MONITORING, SAFETY, RISK AND RESILIENCE OF BRIDGES AND BRIDGE NETWORKS, 2016, : 564 - 564
  • [30] Rain-wind-induced cable vibrations in the Alamillo cable-stayed bridge (Sevilla, Spain). Assessment and remedial action
    Casas, Joan R.
    Aparicio, Angel C.
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2010, 6 (05) : 549 - 556