Implantable cardioverter-defibrillator therapy in Australia, 2002-2015

被引:17
|
作者
Blanch, Bianca [1 ]
Lago, Luise P. [2 ]
Sy, Raymond [3 ]
Harris, Phillip J. [4 ]
Semsarian, Christopher [1 ,3 ,4 ]
Ingles, Jodie [1 ,3 ,4 ]
机构
[1] Centenary Inst, Agnes Ginges Ctr Mol Cardiol, Sydney, NSW, Australia
[2] Univ Wollongong, Ctr Hlth Res, Wollongong, NSW, Australia
[3] Univ Sydney, Sydney Med Sch, Sydney, NSW, Australia
[4] Royal Prince Alfred Hosp, Sydney, NSW, Australia
基金
英国医学研究理事会; 澳大利亚国家健康与医学研究理事会;
关键词
PRIMARY PREVENTION; CARDIAC-ARREST; HEART-FAILURE; UNITED-STATES; AGE; DEATH; ASSOCIATION; COMMUNITY; OUTCOMES; QUALITY;
D O I
10.5694/mja17.01183
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To quantify the number of implantable cardioverter-defibrillator (ICD) procedures in Australia by year, patient age and sex, and to estimate age group-specific population rates and the associated costs. Design, setting: Retrospective observational study; analysis of Australian National Hospital Morbidity Database hospital procedures data. Participants: Patients with an ICD insertion, replacement, adjustment, or removal procedure code, July 2002 - June 2015. Main outcome measures: Number of ICD procedures by procedure year, patient age (0-34, 35-69, 70 years or more) and sex; age group-specific population procedure rates; number of procedures associated with complications. Results: The number of ICD procedures increased from 1844 in 2002-03 to 6504 in 2014-15; more than 75% of procedures were in men. In 2014-15, the ICD insertion rate for people aged 70 years or more was 78.1 per 100 000 population, 22 per 100 000 for those aged 35-69 years, and 1.40 per 100 000 people under 35. The reported complication rate decreased from 45% in 2002-03 to 19% in 2014-15, party because of a change in the coding of complications. The number of removals corresponded to at least 4% of the number of insertions each year. The aggregate cost of hospitalisations with an ICD procedure during 2011-14 was $445 644 566. Conclusion: ICD procedures are becoming more frequent in Australia, particularly in people aged 70 or more. Patterns of care associated with ICD therapy, particularly patient- and hospital-related factors associated with adverse events, should be investigated to better understand and improve patient outcomes.
引用
收藏
页码:123 / 129
页数:7
相关论文
共 50 条
  • [21] The subcutaneous implantable cardioverter-defibrillator
    Grace, Andrew
    CURRENT OPINION IN CARDIOLOGY, 2014, 29 (01) : 10 - 19
  • [22] A prophylactic implantable cardioverter-defibrillator?
    Brugada, P
    Wellens, F
    Andries, E
    AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 : 128 - 133
  • [23] Implantable cardioverter-defibrillator advances
    Lerman, RD
    Cannom, DS
    CURRENT OPINION IN CARDIOLOGY, 1996, 11 (01) : 16 - 22
  • [24] AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    LATTUCA, J
    VELTRI, EP
    AMERICAN HEART JOURNAL, 1989, 118 (06) : 1359 - 1359
  • [25] Indications for implantable Cardioverter-Defibrillator
    Tebbenjohanns, J
    Niehaus, M
    Korte, T
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2002, 127 (41) : 2120 - 2124
  • [26] AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    EPSTEIN, AE
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1991, 102 (01): : 160 - 161
  • [27] The implantable cardioverter-defibrillator: An update
    Miller, Jared D.
    Yousuf, Omair
    Berger, Ronald D.
    TRENDS IN CARDIOVASCULAR MEDICINE, 2015, 25 (07) : 606 - 611
  • [28] Implantable cardioverter-defibrillator utilization
    Camm, John
    EUROPACE, 2011, 13 (03): : 448 - 448
  • [29] Erosion of an Implantable Cardioverter-Defibrillator
    Elmouchi, Darryl
    Woelfel, Alan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (24) : E47 - E47
  • [30] Twiddling with an implantable cardioverter-defibrillator
    McCann, Conor J.
    Beelen, Roel
    Geelen, Peter
    ACTA CARDIOLOGICA, 2009, 64 (05) : 695 - 695