Monte Carlo simulation for correlation analysis of average glandular dose by breast thickness and glandular ratio in breast tissue

被引:2
|
作者
Kim, Sang-Tae [1 ]
Cho, Jung-Keun [2 ]
机构
[1] Nucl Safety & Secur Commiss, Radiat Safety Div, Seoul, South Korea
[2] Jeonju Univ, Dept Radiol Sci, Jeonju, South Korea
关键词
Glandular; average glandular dose; Monte Carlo simulation; breast thickness; MAMMOGRAPHY;
D O I
10.3233/THC-140790
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
A glandular breast tissue is a radio-sensitive tissue. So during the evaluation of an X-ray mammography device, Average Glandular Dose (AGD) measurement is a very important part. In reality, it is difficult to measure AGD directly, Monte Carlo simulation was used to analyze the correlation between the AGD and breast thickness. As a result, AGDs calculated through the Monte Carlo simulation were 1.64, 1.41 and 0.88 mGy. The simulated AGDs mainly depend on the glandular ratio of the breast. With the increase of glandular breast tissue, absorption of low photon-energy increased so that the AGDs increased, too. In addition, the thicker the breast was, the more the AGD became. Consequently, this study will be used as basic data for establishing the diagnostic reference levels of mammography.
引用
收藏
页码:345 / 350
页数:6
相关论文
共 50 条
  • [1] Monte Carlo Simulation of Glandular Breast Dose in Mammography Using Breast CT-Derived Glandular Distributions
    Hernandez, A.
    Boone, J.
    Seibert, J.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3548 - 3548
  • [2] Monte Carlo simulation of glandular dose in a dedicated breast CT system
    Tang Xiao
    Zhao Wei
    Wang Yan-Fang
    Shu Hang
    Sun Cui-Li
    Wei Cun-Feng
    Cao Da-Quan
    Que Jie-Min
    Shi Rong-Jian
    Wei Long
    [J]. CHINESE PHYSICS C, 2012, 36 (07) : 675 - 680
  • [3] Monte Carlo simulation of glandular dose in a dedicated breast CT system
    唐晓
    赵维
    王燕芳
    舒航
    孙翠丽
    魏存峰
    曹大泉
    阙介民
    史戎坚
    魏龙
    [J]. Chinese Physics C, 2012, 36 (07) : 675 - 680
  • [4] Monte Carlo simulation for the estimation of the glandular breast dose for a digital breast tomosynthesis system
    Rodrigues, Leonardo
    Goncalves Magalhaes, Luis Alexandre
    Braz, Delson
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 167 (04) : 576 - 583
  • [5] Monte Carlo Simulation of Average Glandular Dose and an Investigation of Influencing Factors
    Nigapruke, Khatayut
    Puwanich, Patana
    Phaisangittisakul, Nakorn
    Youngdee, Wiwat
    [J]. JOURNAL OF RADIATION RESEARCH, 2010, 51 (04) : 441 - 448
  • [6] Evaluation of glandular dose in mammography in presence of breast cysts using Monte Carlo simulation
    Deevband, Mohammad Reza
    Kaveh, Zeinab
    Ghorbani, Mahdi
    Khajetash, Benyamin
    [J]. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2021, 27 (01): : 41 - 50
  • [7] Average Glandular Dose in Digital Mammography and Breast Tomosynthesis
    Olgar, T.
    Kahn, T.
    Gosch, D.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2012, 184 (10): : 911 - 918
  • [8] MONTE-CARLO CALCULATION OF CONVERSION FACTORS FOR THE ESTIMATION OF MEAN GLANDULAR BREAST DOSE
    DANCE, DR
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (09): : 1211 - 1219
  • [9] Association of the Differences in Average Glandular Dose with Breast Cancer Risk
    Ma, Le
    Cai, Yuxing
    Lin, Xiaojia
    He, Zilong
    Zeng, Hui
    Chen, Weiguo
    Qin, Genggeng
    [J]. BIOMED RESEARCH INTERNATIONAL, 2020, 2020
  • [10] Breast Glandular Tissue Volume and Volumetric Glandular Ratio Using Dual-Energy Mammography
    Pacheco-Guevara, G.
    Castillo-Lopez, J.
    Villasenor-Navarro, Y.
    Brandan, M. E.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E308 - E308