A new and sensitive method for measuring in vivo and in vitro cytotoxicity in earthworm coelomocytes by flow cytometry

被引:26
|
作者
Kwak, Jin Il [1 ]
Kim, Shin Woong [1 ]
An, Youn-Joo [1 ]
机构
[1] Konkuk Univ, Dept Environm Sci, 1 Hwayang Dong, Seoul 143701, South Korea
关键词
Earthworm; Calcein-AM; Coelomocytes; Cytotoxicity; Flow cytometry; LUMBRICUS-TERRESTRIS; EISENIA-FOETIDA; ENZYME-ACTIVITIES; VIABILITY ASSESSMENT; LYSOSOMAL BIOMARKER; BURROWING BEHAVIOR; ACUTE TOXICITY; DAPHNIA-MAGNA; APOPTOSIS; SOIL;
D O I
10.1016/j.envres.2014.07.014
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study describes a new and sensitive method for measuring the in vivo and in vitro cytotoxicity of 2 earthworm species, Eisenia andrei and Perionyx excavatus, exposed to copper. Specifically, we measured the number of coelomocyte cells that were affected by copper following in vivo and in vitro exposure by flow cytometry, after calcein acetoxymethyl ester (calcein-AM) staining. We found that the coelomocyte viability of both earthworm species was noticeably reduced in the in vivo cytotoxicity test at concentrations of 100 mg/kg copper in dry soil. However, pathological symptoms, such as mucous secretion and bleeding, swelling, thinning, and fragmentation, and burrowing symptoms were not evident following exposure to copper levels of <400 mg/kg dry soil. In conclusion, the present study demonstrates that calcein-AM is a more sensitive test of earthworm coelomocyte cytotoxicity compared to the traditional individual level toxicity test. Therefore, this test could be used to detect low levels of metal contamination in soils. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:118 / 126
页数:9
相关论文
共 50 条
  • [41] NEW METHOD OF MEASURING RENAL BLOOD FLOW
    GARSENSTEIN, M
    SHALDON, S
    WALKER, G
    RYDER, J
    HIGGS, B
    JOURNAL OF PHYSIOLOGY-LONDON, 1962, 162 (01): : P21 - &
  • [42] New method to detect histone acetylation levels by flow cytometry
    Ronzoni, S
    Faretta, M
    Ballarini, M
    Pelicci, P
    Minucci, S
    CYTOMETRY PART A, 2005, 66A (01) : 52 - 61
  • [43] A new method for the detection of Pneumocystis jirovecii using flow cytometry
    J. Barbosa
    C. Bragada
    S. Costa-de-Oliveira
    E. Ricardo
    A. G. Rodrigues
    C. Pina-Vaz
    European Journal of Clinical Microbiology & Infectious Diseases, 2010, 29 : 1147 - 1152
  • [44] TESTS OF A NEW METHOD OF MEASURING THE FLOW OF URINE
    FABRICIUS, PG
    NIEDERLAG, W
    MATZ, M
    DEUTSCHE GESUNDHEITSWESEN-ZEITSCHRIFT FUR KLINISCHE MEDIZIN, 1981, 36 (01): : 35 - 37
  • [45] A new in vivo method for measuring caries activity with a colorimeter
    C. Meller
    A. Söhnel
    C. Splieth
    Clinical Oral Investigations, 2006, 10 : 140 - 144
  • [46] New method to characterize microbial diversity using flow cytometry
    Park, HS
    Schumacher, R
    Kilbane, JJ
    JOURNAL OF INDUSTRIAL MICROBIOLOGY & BIOTECHNOLOGY, 2005, 32 (03) : 94 - 102
  • [47] A new method for the detection of Pneumocystis jirovecii using flow cytometry
    Barbosa, J.
    Bragada, C.
    Costa-de-Oliveira, S.
    Ricardo, E.
    Rodrigues, A. G.
    Pina-Vaz, C.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2010, 29 (09) : 1147 - 1152
  • [48] A New Method of Bone Stromal Cell Characterization by Flow Cytometry
    Patel, Chirayu
    Shi, Lihong
    Whitesides, John F.
    Foster, Brittni M.
    Fajardo, Roberto J.
    Quillen, Ellen E.
    Kerr, Bethany A.
    CURRENT PROTOCOLS, 2022, 2 (03):
  • [49] FLOW CYTOMETRIC METHOD OF MEASURING INVITRO DRUG-INDUCED LYMPHOCYTE CYTOTOXICITY
    WHEELER, JG
    CHILDRESS, SH
    KEARNS, GL
    CLINICAL RESEARCH, 1992, 40 (04): : A804 - A804
  • [50] Validation of ACB in vitro and in vivo as a biomagnetic method for measuring stomach contraction
    Americo, M. F.
    Marques, R. G.
    Zandona, E. A.
    Andreis, U.
    Stelzer, M.
    Cora, L. A.
    Oliveira, R. B.
    Miranda, J. R. A.
    NEUROGASTROENTEROLOGY AND MOTILITY, 2010, 22 (12): : 1340 - E374