Analytical performance of glucometers in a tertiary care hospital

被引:3
|
作者
Higioka, Angela Somavilla [1 ,2 ]
Messores Rudolf-Oliveira, Renata Cristina [2 ,3 ]
Martinello, Flavia [1 ,4 ]
Bazzo, Maria Luiza [1 ,2 ,3 ]
机构
[1] Univ Fed Santa Catarina, Residencia Multidisciplinar Saude, Univ Hosp, Florianopolis, SC, Brazil
[2] Univ Fed Santa Catarina, Lab Pesquisa 3, Div Anal Clin, Hosp Univ Prof Polydoro Ernani de Sao Thiago, Campus Univ S-No,Segundo Andar, BR-88040900 Florianopolis, SC, Brazil
[3] Univ Fed Santa Catarina, Dept Clin Anal, Program Post Grad Pharm, Florianopolis, SC, Brazil
[4] Univ Fed Santa Catarina, Dept Anal Clin, Ctr Ciencias Saude, Sala 109,Bloco JK, BR-88040900 Florianopolis, SC, Brazil
关键词
Point-of-care tests; Capillary glucose; Glucometer; Accuracy assessment; GLUCOSE MEASUREMENT;
D O I
10.1007/s00769-015-1188-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Point-of-care (POC) testing of glucose (glucometers) represents a convenient alternative to monitor glycemia since the measurement procedure is performed without delay after sampling of the capillary blood, thereby avoiding the metabolism by the blood cells of glucose present in plasma. Likely because of sample instability, there is no proficiency test provider in Brazil for this type of POC sample. In this context, this study aimed to evaluate the analytical performance of glucometers used in a tertiary care hospital. The glucometers used were the Accu-Chek Performa(A (R)) model from Roche Diagnostics, which use the principle of amperometry. The reference method was the reaction with modified hexokinase/glucose-6-phosphate in a Dimension(A (R)) device. The stability evaluation of the control samples showed that it can be performed up to 90 min after the collection of whole blood samples. In the two rounds performed, only one result of the 17 glucometers evaluated was out of the threshold of two standard deviation. Thus, this method for control of glucometers met the expectations and enabled comparing the glucometers in a hospital. Given the current quality guidelines, daily internal quality control of glucometers is recommended, besides at least two annual comparisons between the results of the glucometers and the reference method and one EQA every 3 months.
引用
收藏
页码:143 / 149
页数:7
相关论文
共 50 条
  • [1] Analytical performance of glucometers in a tertiary care hospital
    Angela Somavilla Higioka
    Renata Cristina Messores Rudolf-Oliveira
    Flavia Martinello
    Maria Luiza Bazzo
    Accreditation and Quality Assurance, 2016, 21 : 143 - 149
  • [2] Clarke Error Grid Analysis for Performance Evaluation of Glucometers in a Tertiary Care Referral Hospital
    Sengupta, Sohini
    Handoo, Anil
    Haq, Inaamul
    Dahiya, Karamvir
    Mehta, Sanjay
    Kaushik, Mradul
    INDIAN JOURNAL OF CLINICAL BIOCHEMISTRY, 2022, 37 (02) : 199 - 205
  • [3] Clarke Error Grid Analysis for Performance Evaluation of Glucometers in a Tertiary Care Referral Hospital
    Sohini Sengupta
    Anil Handoo
    Inaamul Haq
    Karamvir Dahiya
    Sanjay Mehta
    Mradul Kaushik
    Indian Journal of Clinical Biochemistry, 2022, 37 : 199 - 205
  • [4] Analytical performance of publicly dispensed glucometers in primary health care in a southern Brazilian city
    Silva, Isabelle L.
    Martinello, Flavia
    PRACTICAL LABORATORY MEDICINE, 2024, 41
  • [5] Assessment of analytical performance of glucose meter in pediatric age group at tertiary care referral hospital
    Rojekar M.V.
    Kumawat V.
    Panot J.
    Khedkar S.
    Adhe-Rojekar A.
    Journal of Diabetes & Metabolic Disorders, 16 (1):
  • [6] Variability of point-of-care testing blood glucometers versus the laboratory reference method in a tertiary teaching hospital
    Jamaluddin, Farhi Ain
    Gunavathy, M.
    Yean, Chew Yee
    Thevarajah, Malathi
    ASIAN BIOMEDICINE, 2012, 6 (01) : 67 - 74
  • [7] Performance of the gel antibody screen in a tertiary care hospital.
    Lane, TA
    Buenviaje, J
    Gonzalez, J
    Alvarez, Z
    BLOOD, 1996, 88 (10) : 716 - 716
  • [8] ANALYTICAL INTERFERENCES IN POINT-OF-CARE TESTING GLUCOMETERS BY ICODEXTRIN AND ITS METABOLITES: AN OVERVIEW
    Flore, Katelijne M. J.
    Delanghe, Joris R.
    PERITONEAL DIALYSIS INTERNATIONAL, 2009, 29 (04): : 377 - 383
  • [9] Analytical performance of glucometers used for routine glucose self-monitoring of diabetic patients
    Solnica, B
    Naskalski, JW
    Sieradzki, J
    CLINICA CHIMICA ACTA, 2003, 331 (1-2) : 29 - 35
  • [10] Performance of Lower GI Bleeding Scores in a Large Tertiary Care Hospital
    Cheung, Randy
    Fazel, Yousef
    Sparacino, Gina
    Sadek, Sarah
    Tahir, Muhammad
    Gudleski, Gregory D.
    Mahmood, Sultan
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2020, 115 : S308 - S309