Variability of point-of-care testing blood glucometers versus the laboratory reference method in a tertiary teaching hospital

被引:7
|
作者
Jamaluddin, Farhi Ain [1 ]
Gunavathy, M. [2 ]
Yean, Chew Yee [3 ]
Thevarajah, Malathi [1 ]
机构
[1] Univ Malaya, Fac Med, Dept Pathol, Med Ctr, Kuala Lumpur 50903, Malaysia
[2] Univ Malaya, Med Ctr, Dept Med, Kuala Lumpur 50903, Malaysia
[3] Univ Malaya, Med Ctr, Div Lab Med, Kuala Lumpur 50903, Malaysia
关键词
Glucometers; glucose; POCT; variation;
D O I
10.5372/1905-7415.0506.128
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Self-monitoring blood glucose (SMBG) has been established as a part of the point-of-care testing (POCT) in the management of patients diagnosed with diabetes mellitus. Various glucometers in the market have been used for this purpose but most are calibrated to whole blood. The recent recommendation by the International Federation of Clinical Chemistry (IFCC) is for glucose to be reported in plasma equivalent units which should correlate well with the clinical laboratory reference method. This is to minimize as much as possible the differences normally seen in the capillary whole blood glucose levels obtained during SMBG and routine plasma glucose levels reported by the laboratory. Objective: We evaluated the accuracy of four commercial blood glucose strips currently available in the local hospital setting against the laboratory reference method. Methods: We analyzed 145 whole blood samples collected into plain tubes from the walk-in patients in the hospital. A simultaneously whole blood sample was collected in sodium fluoride tubes and analyzed by the routine laboratory hexokinase method (RxL, Siemens). The four different types of glucometer strips used were AccuChek Performa, AccuChek Advantage, Abbott Optium and Johnson & Johnson Surestep. Results: The overall correlation coefficient for the four strips showed that the Accuchek Performa compared closest to the laboratory method which is R-2=0.9761. This was followed by the Accuchek Advantage R-2=0.9726. The Optium and Surestep systems showed R-2=0.9376 and R-2=0.9277 respectively. The coefficient variance (CV) for the Accuchek Performa is also <5% for both the control and sample precision. The ISO15197.2003 (E) acceptance criteria: percentage of individual results falling outside 0.8 mmol/L at glucose concentrations <4.1mmol/L and outside 20% of the reference result at glucose concentrations >4.1 mmol/L will not be higher than 5% showed that the compliance for Performa is 100% compared to the rest (for percentage of results within 95% compliance limit). Conclusion: The results showed that the Accuchek Performa system compared the closest to the laboratory method and complies to the ISO15197.2003 (E) with acceptable CV's.
引用
收藏
页码:67 / 74
页数:8
相关论文
共 50 条
  • [1] Point-of-care Laboratory Testing
    Gauglitz, Guenter
    Luppa, Peter B.
    [J]. CHEMIE IN UNSERER ZEIT, 2009, 43 (05) : 308 - 318
  • [2] Point-of-care Testing versus Central Laboratory Testing of Electrolytes in Neonates
    Choi, Ha-young
    Corder, Wil
    Abubakar, Kabir
    [J]. PEDIATRICS, 2018, 141
  • [3] Accuracy of Point-of-Care Blood Glucometers in Neonates and Critically Ill Adults
    Sheen, Yi-Jing
    Wang, Jiunn-Min
    Tsai, Pi-fen
    Lee, Wen-Jane
    Hsu, Ya-Chi
    Wang, Chen-Yu
    Sheu, Wayne H. -H.
    [J]. CLINICAL THERAPEUTICS, 2023, 45 (07) : 643 - 648
  • [4] Reproducibility of thrombelastometry (ROTEM®): Point-of-care versus hospital laboratory performance
    Haas, Thorsten
    Spielmann, Nelly
    Mauch, Jacqueline
    Speer, Oliver
    Schmugge, Markus
    Weiss, Markus
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2012, 72 (04): : 313 - 317
  • [5] Point-of-care aPTT testing versus established laboratory based systems
    Risch, A
    Biedler, A
    Mertzlufft, F
    [J]. ANESTHESIOLOGY, 1996, 85 (3A) : A454 - A454
  • [6] Point-of-care versus central laboratory testing of INR in acute stroke
    Zenlander, R.
    von Euler, M.
    Antovic, J.
    Berglund, A.
    [J]. ACTA NEUROLOGICA SCANDINAVICA, 2018, 137 (02): : 252 - 255
  • [7] ANALYTICAL INTERFERENCES IN POINT-OF-CARE TESTING GLUCOMETERS BY ICODEXTRIN AND ITS METABOLITES: AN OVERVIEW
    Flore, Katelijne M. J.
    Delanghe, Joris R.
    [J]. PERITONEAL DIALYSIS INTERNATIONAL, 2009, 29 (04): : 377 - 383
  • [8] Point-of-Care Testing of Blood Glucose: Clinical Performance and Laboratory Efficiency
    Shih, Wei-Shang
    Yang, Pei-Fang
    Chi, Tzu-Fei
    Huang, Liang Li
    Chen, Chang-I
    Wang, Mei-Xuan
    Ho, Yi-Ting
    [J]. JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2019, 13 (09) : BC10 - BC13
  • [9] Utility of point-of-care vs reference laboratory testing for the evaluation of glucose levels
    Andriankaja, O. M.
    Munoz-Torres, F. J.
    Vergara, J. L.
    Perez, C. M.
    Joshipura, K.
    [J]. DIABETIC MEDICINE, 2019, 36 (05) : 626 - 632
  • [10] The real world of blood glucose point-of-care testing (POCT) system running in China teaching hospital
    Li, Feng-fei
    Xie, Yun
    Shi, Bing-yin
    Niu, Min
    Guo, Hui
    Cao, Yan
    Liu, Bing-li
    Yan, Reng-na
    Su, Xiao-fei
    Wu, Jin-dan
    Zhang, Dan-feng
    Chen, Li-ming
    Ma, Jian-hua
    [J]. EXPERT REVIEW OF MEDICAL DEVICES, 2018, 15 (06) : 445 - 451