Carbon dioxide-based portography: An alternative to conventional imaging with the use of iodinated contrast medium

被引:8
|
作者
Maruyama, Hitoshi [1 ]
Okugawa, Hidehiro [1 ]
Ishibashi, Hiroyuki [1 ]
Takahashi, Masanori [1 ]
Kobayashi, Satoshi [1 ]
Yoshizumi, Hiroaki [1 ]
Yokosuka, Osamu [1 ]
机构
[1] Chiba Univ, Grad Sch Med, Dept Med & Clin Oncol, Chuou Ku, Chiba 2608670, Japan
关键词
carbon dioxide; contrast medium; portography; portal hypertension; PERCUTANEOUS TRANSHEPATIC PORTOGRAPHY; DIGITAL-SUBTRACTION-ANGIOGRAPHY; WEDGED HEPATIC VENOGRAPHY; PORTAL-VEIN EMBOLIZATION; CO2; SPLENOPORTOGRAPHY; VENOUS STENOSIS; GASTRIC VEIN; HEMODYNAMICS; HYPERTENSION; ESOPHAGEAL;
D O I
10.1111/j.1440-1746.2010.06248.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aim: To clarify the efficacy of carbon dioxide (CO2) as a contrast material to evaluate portal vein images by percutaneous transhepatic portography (PTP). Methods: Twenty patients (38-76 years; male 13, female 7) with chronic liver diseases were the subjects of this prospective study. Portal venous opacification by PTP was compared between CO2-based images and iodinated contrast medium (ICM)-based images by two independent reviewers, according to the three-grade scoring; 0 for none, 1 for weak and 2 for sufficient. Results: Total scores of extrahepatic portal veins (137 for CO2, 93 for ICM), collateral vessels (64 for CO2, 60 for ICM) and intrahepatic portal veins (69 for CO2, 76 for ICM) were not statistically significant between CO2-based and ICM-based images (P = 0.0623). Sufficient opacification of superior mesenteric vein was more frequent on CO2-based images (none 0, weak 4, sufficient 16) than ICM-based images (none 19, weak 0, sufficient 1; P < 0.0001). The score was not statistically significant between CO2-based and ICM-based images in portal trunk, splenic vein, inferior mesenteric vein and other collateral vessels. Although opacification grade in the intrahepatic left portal vein was not statistically significant between CO2-based and ICM-based images (P = 0.1515), weak opacification was significantly frequent on CO2-based images (weak 10, sufficient 10) compared to ICM-based images (weak 0, sufficient 20; P = 0.0003) in the intrahepatic right portal vein. Inter-reviewer agreement was excellent between the two reviewers for CO2-based images (kappa = 0.913) and ICM-based images (kappa = 0.924). Conclusions: Carbon dioxide may be a first-line contrast material for evaluating portal vein images by PTP.
引用
收藏
页码:1111 / 1116
页数:6
相关论文
共 50 条
  • [21] Platinum Electrodeposition from a Carbon Dioxide-Based Supercritical Electrolyte
    Ursov, E. D.
    Kondratenko, M. S.
    Gallyamov, M. O.
    DOKLADY PHYSICAL CHEMISTRY, 2019, 489 (02) : 173 - 176
  • [22] Platinum Electrodeposition from a Carbon Dioxide-Based Supercritical Electrolyte
    E. D. Ursov
    M. S. Kondratenko
    M. O. Gallyamov
    Doklady Physical Chemistry, 2019, 489 : 173 - 176
  • [23] Carbon dioxide-based supercritical fluids as IC manufacturing solvents
    Rubin, JB
    Davenhall, LB
    Taylor, CMV
    Sivils, LD
    Pierce, T
    Tiefert, K
    PROCEEDINGS OF THE 1999 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRONICS AND THE ENVIRONMENT, ISEE - 1999, 1999, : 13 - 20
  • [24] Carbon Dioxide-Based Neutralization of High-Density Sludge Effluents as a Sustainable Climate and Water Quality Alternative to the Use of Strong Mineral Acids
    Gastanadui-Cruz, Julio C.
    Reyes-Lopez, Ivan A.
    Cortijo-Garcia, Agusberto
    Portilla-Rodriguez, Hans R.
    Bush, John A.
    Vanneste, Johan
    Garcia-Chevesich, Pablo A.
    SUSTAINABILITY, 2024, 16 (23)
  • [25] COMPARISON OF DIAGNOSTIC-ACCURACY WITH CARBON-DIOXIDE VERSUS IODINATED CONTRAST MATERIAL IN THE IMAGING OF HEMODIALYSIS ACCESS FISTULAS
    EHRMAN, KO
    TABER, TE
    GAYLORD, GM
    BROWN, PB
    HAGE, JP
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1994, 5 (05) : 771 - 775
  • [26] Carbon Dioxide Angiography Allows Endovascular Aneurysm Repair to Be Performed With Zero Iodinated Contrast Medium Under Specific Anatomic Conditions
    Vacirca, Andrea
    Faggioli, Gianluca
    Mascoli, Chiara
    Gallitto, Enrico
    Pini, Rodolfo
    Spath, Paolo
    Logiacco, Antonino
    Gargiulo, Mauro
    JOURNAL OF VASCULAR SURGERY, 2020, 72 (01) : E48 - E48
  • [27] Catalysis in carbon dioxide-based media: Opportunities and challenges.
    Subramaniam, B
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2004, 228 : U838 - U838
  • [28] Physiology of Intraluminal Administration of Carbon Dioxide as a Contrast Medium
    Patelis, Nikolaos
    Doulaptsis, Mikes
    Kykalos, Stylianos
    Spartalis, Eleftherios
    Maskanakis, Anastasios
    Georgopoulos, Sotirios
    CURRENT PHARMACEUTICAL DESIGN, 2019, 25 (44) : 4656 - 4661
  • [29] RETROGRADE PYELOGRAPHY WITH GAS (CARBON DIOXIDE) AS CONTRAST MEDIUM
    CHRISTIANSEN, J
    ACTA CHIRURGICA SCANDINAVICA, 1970, 136 (05): : 441 - +
  • [30] Safety of carbon dioxide as a contrast medium in cerebral angiography
    Wilson, AJ
    Boxer, MM
    ACADEMIC RADIOLOGY, 1998, 5 : S51 - S53