A diode laser stabilization scheme for 40Ca+ single-ion spectroscopy

被引:17
|
作者
Rohde, F. [1 ]
Almendros, M. [1 ]
Schuck, C. [1 ]
Huwer, J. [1 ]
Hennrich, M. [1 ]
Eschner, J. [1 ]
机构
[1] ICFO Inst Ciencies Foton, E-08860 Barcelona, Spain
关键词
FREQUENCY MEASUREMENTS; TRANSFER CAVITY; SPECTROMETER; ENTANGLEMENT; REALIZATION; RESONATOR; QUBITS; PHASE; GATE;
D O I
10.1088/0953-4075/43/11/115401
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present a scheme for stabilizing multiple lasers at wavelengths between 795 and 866 nm to the same atomic reference line. A reference laser at 852 nm is stabilized to the Cs D-2 line using a Doppler-free frequency modulation technique. Through transfer cavities, four lasers are stabilized to the relevant atomic transitions in Ca-40(+). The rms linewidth of a transfer-locked laser is measured to be 123 kHz over 200 ms with respect to an independent atomic reference, the Rb D-1 line. This stability is confirmed by the comparison of an excitation spectrum of a single Ca-40(+) ion to an eight-level Bloch equation model. The long-term stability with respect to the same reference is measured to be 130 kHz over a period of 2 h. The high degree of stability is demonstrated by the measured Allan deviation around 10(-11) between 1 and 100 s.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Measurement of Magnetic Field Stability Using 40Ca+ ion
    Tuan Minh Pham
    Lesundak, Adam
    Cizek, Martin
    Rerucha, Simon
    Lazar, Petr Jedlicka Josef
    Cip, Ondrej
    Podhora, Lukas
    Slodicka, Lukas
    2021 JOINT CONFERENCE OF THE EUROPEAN FREQUENCY AND TIME FORUM AND IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM (IEEE EFTF-IFCS 2021), 2021,
  • [32] Three-Dimensional Array for 40Ca+ Ion Trapping
    Wan Jin-Yin
    Liu Liang
    CHINESE PHYSICS LETTERS, 2009, 26 (04)
  • [33] Coherent manipulation of a 40Ca+ spin qubit in a micro ion trap
    Poschinger, U. G.
    Huber, G.
    Ziesel, F.
    Deiss, M.
    Hettrich, M.
    Schulz, S. A.
    Singer, K.
    Poulsen, G.
    Drewsen, M.
    Hendricks, R. J.
    Schmidt-Kaler, F.
    JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 2009, 42 (15)
  • [34] A frequency comb stabilized Ti:Sa laser as a self-reference for ion-trap experiments with a 40Ca+ ion
    Dominguez, F.
    Banuelos, J.
    Berrocal, J.
    del Pozo, J. J.
    Hernandez, M.
    Carrasco-Sanz, A.
    Cerrillo, J.
    Escobedo-Araque, P.
    Rodriguez, D.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2022, 93 (09):
  • [35] A cryogenic radio-frequency ion trap for a 40Ca+ optical clock
    Zeng, Mengyan
    Huang, Yao
    Zhang, Baolin
    Ma, Zixiao
    Hao, Yanmei
    Hu, Ruming
    Zhang, Huaqing
    Guan, Hua
    Gao, Kelin
    CHINESE PHYSICS B, 2023, 32 (11)
  • [36] Compact vacuum setup for 27Al+ and 40Ca+ ion trapping
    Grim, J.
    Vlcek, I
    Jedlicka, P.
    Pham, M. T.
    Lesundak, A.
    Rerucha, S.
    Cizek, M.
    Kovalenko, A.
    Slodicka, L.
    Cip, O.
    22ND POLISH-SLOVAK-CZECH OPTICAL CONFERENCE ON WAVE AND QUANTUM ASPECTS OF CONTEMPORARY OPTICS, 2022, 12502
  • [37] A combined magnetic field stabilization system for improving the stability of 40Ca+ optical clock
    Zeng, Mengyan
    Ma, Zixiao
    Hu, Ruming
    Zhang, Baolin
    Hao, Yanmei
    Zhang, Huaqing
    Hung, Yao
    Guan, Hua
    Gao, Kelin
    CHINESE PHYSICS B, 2023, 32 (11)
  • [38] A combined magnetic field stabilization system for improving the stability of 40Ca+ optical clock
    曾孟彦
    马子晓
    胡如明
    张宝林
    郝艳梅
    张华青
    黄垚
    管桦
    高克林
    Chinese Physics B, 2023, (11) : 268 - 273
  • [39] Phase-locked laser system for a metastable states qubit in 40Ca+
    Yamazaki, Rekishu
    Iwai, Toshiki
    Toyoda, Kenji
    Urabe, Shinji
    OPTICS LETTERS, 2007, 32 (15) : 2085 - 2087
  • [40] Rydberg Series Excitation of a Single Trapped 40Ca+ Ion for Precision Measurements and Principal Quantum Number Scalings
    Andrijauskas, J.
    Vogel, J.
    Mokhberi, A.
    Schmidt-Kaler, F.
    PHYSICAL REVIEW LETTERS, 2021, 127 (20)