Past magnetic resonance imaging of the abdomen with turbo-spin-echo pulse sequences

被引:0
|
作者
Yu, BC [1 ]
Jara, H [1 ]
Yucel, EK [1 ]
机构
[1] Boston Univ, Coll Gen Studies, Boston, MA 02215 USA
关键词
D O I
暂无
中图分类号
O59 [应用物理学];
学科分类号
摘要
The purposes of this study was to optimize T2-weighted hybrid-RARE pulse sequences for clinical MR imaging of the liver. The ranges of the key scan variables, echo train length (ETL) and effective echo time (TEeff) were investigated. A total of thirteen "healthy" volunteers were scanned at 1.5 Tesla with an extensive array of hybrid-RARE pulses. Results indicated that the image quality of hybrid-RARE sequences with ETL of 11 and higher, regardless of the choice of TEeff were graded better than the reference conventional spin-echo (CSE) pulse sequence(p < 0.005). The image contrast between liver and spleen at higher ETL (greater than or equal to 13) were consistently superior compared to both CSE and the lower ETL sequences(p < 0.05), particularly at TEeff equals 120 ms (p < 0.01).
引用
收藏
页码:304 / 326
页数:23
相关论文
共 50 条
  • [31] Non-invasive temperature imaging of muscles with magnetic resonance imaging using spin-echo sequences
    Department of Biomedical Engineering, Medical Faculty, Ruhr-University, D-44780 Bochum, Germany
    不详
    不详
    Med. Biol. Eng. Comput., 6 (673-678):
  • [32] 1H magnetic resonance imaging of human lung using inversion recovery turbo spin echo
    Mai, VM
    Knight-Scott, J
    Edelman, RR
    Chen, Q
    Keilholz-George, S
    Berr, SS
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 11 (06) : 616 - 621
  • [33] Prenatal diagnosis of fetal urogenital abnormalities with oligohydramnios by magnetic resonance imaging using turbo spin echo technique
    Takeuchi, K
    Moriyama, T
    Funakoshi, T
    Maruo, T
    JOURNAL OF PERINATAL MEDICINE, 1998, 26 (01) : 59 - 61
  • [34] RADIAL TURBO SPIN-ECHO IMAGING
    RASCHE, V
    HOLZ, D
    SCHEPPER, W
    MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (05) : 629 - 638
  • [35] Density weighted turbo spin echo imaging
    Zeller, Mario
    Gutberlet, Marcel
    Staeb, Daniel
    Ritter, Christian Oliver
    Beer, Meinrad
    Hahn, Dietbert
    Koestler, Herbert
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (04) : 965 - 973
  • [36] Reducing Contrast Contamination in Radial Turbo-Spin-Echo Acquisitions by Combining a Narrow-Band KWIC Filter with Parallel Imaging
    Neumann, Daniel
    Breuer, Felix A.
    Voelker, Michael
    Brandt, Tobias
    Griswold, Mark A.
    Jakob, Peter M.
    Blaimer, Martin
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (06) : 1680 - 1686
  • [37] EFFECTS OF SUPERPARAMAGNETIC IRON-OXIDE (AMI-25) ON LIVER AND SPLEEN IMAGING USING SPIN-ECHO AND FAST SPIN-ECHO MAGNETIC-RESONANCE PULSE SEQUENCES
    SCHWARTZ, LH
    SELTZER, SE
    ADAMS, DF
    TEMPANY, CMC
    PIWNICAWORMS, DR
    SILVERMAN, SG
    HERMAN, L
    HERMAN, LT
    HOOSHMAND, R
    INVESTIGATIVE RADIOLOGY, 1994, 29 : S21 - S23
  • [38] Magnetic resonance imaging of the upper abdomen using a free-breathing T2-weighted turbo spin echo sequence with navigator triggered prospective acquisition correction
    Klessen, C
    Asbach, P
    Kroencke, TJ
    Fischer, T
    Warmuth, C
    Stemmer, A
    Hamm, B
    Taupitz, M
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (05) : 576 - 582
  • [39] MULTIPLE SPIN-ECHO MAGNETIC-RESONANCE IMAGING
    FEINBERG, DA
    MILLS, CM
    POSIN, JP
    ORTENDAHL, DA
    HYLTON, NM
    CROOKS, LE
    WATTS, JC
    KAUFMAN, L
    ARAKAWA, M
    HOENNINGER, JC
    BRANTZAWADZKI, M
    RADIOLOGY, 1985, 155 (02) : 437 - 442
  • [40] Functional turbo spin echo magnetic resonance imaging versus tomography for evaluating cervical spine involvement in rheumatoid arthritis
    Oostveen, JCM
    Roozeboom, AR
    van de Laar, MAFJ
    Heeres, J
    den Boer, JA
    Lindeboom, SF
    SPINE, 1998, 23 (11) : 1237 - 1244