Immediate effects of whole blood donation on the endothelial surface layer and glycocalyx shedding

被引:8
|
作者
Fuchs, Alexander [1 ,2 ]
Gross, Sabine [1 ,2 ]
Neumann, Tobias [1 ,2 ]
Illerhauss, Anja [1 ,3 ]
Vink, Hans [4 ]
Klasen, Gerda [1 ,5 ]
Gathof, Birgit [1 ,5 ]
Annecke, Thorsten [1 ,2 ,6 ]
机构
[1] Univ Cologne, Fac Med, Cologne, Germany
[2] Univ Hosp Cologne, Dept Anaesthesiol & Intens Care Med, Cologne, Germany
[3] Univ Hosp Cologne, Dept Dermatol, Cologne, Germany
[4] Maastricht Univ Med Ctr, Dept Physiol, Maastricht, Netherlands
[5] Univ Hosp Cologne, Inst Transfus Med, Cologne, Germany
[6] Univ Witten Herdecke, Kliniken Stadt Koln gGmbH, Dept Anaesthesiol & Intens Care Med, Cologne, Germany
关键词
blood donors; haemorrhage; shock; glycocalyx; intravital microscopy; SUBLINGUAL MICROVASCULAR GLYCOCALYX; HEMORRHAGIC-SHOCK; DYSFUNCTION;
D O I
10.2450/2020.0025-20
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - The endothelium plays a pivotal role in regulating microvascular function, especially in situations associated with acute blood loss. Whether blood donation and the associated volume loss affects the dimensions of the endothelial surface layer (ESL) and glycocalyx integrity remains unknown. Materials and methods - This study was designed to determine real-time ESL and perfusion measurements of the sublingual microcirculation using sidestream dark field imaging performed in healthy subjects shortly before and after a donation of 500 mL whole blood. A novel image acquisition and analysis software (GlycoCheckT) automatically calculated the perfused boundary region (PBR), an inverse parameter for red blood cell (RBC) penetration into the ESL, in vessels between 5 and 25 mu m in diameter. Microvascular perfusion was measured by RBC filling percentage. Soluble glycocalyx components were determined in the peripheral circulation. Results - There was no significant immediate effect of whole blood donation on PBR and RBC filling percentage. Linear regression analysis revealed a distinct association between change in PBR and change in RBC filling percentage (regression coefficient beta: -0.040; 95% confidence interval: -0.049 to -0.030; p<0.001). A significant reduction in plasma heparan sulphate (1,329 +/- 316 vs 1,237 +/- 275 ng/mL, p=0.005) and hyaluronan (94 +/- 18 vs 90 +/- 16 ng/mL, p=0.002) was noted, while syndecan-1 levels (30 [23-50] vs 29 [24-46] ng/mL, p=0.282) remained unchanged. Discussion - Dimensions and integrity of the ESL appear to remain stable following a 500 mL whole blood donation and reflect its ability to ensure microvascular function and perfusion.
引用
收藏
页码:190 / 196
页数:7
相关论文
共 49 条
  • [31] Microvasculature on a chip: study of the Endothelial Surface Layer and the flow structure of Red Blood Cells
    Tsvirkun, Daria
    Grichine, Alexei
    Duperray, Alain
    Misbah, Chaouqi
    Bureau, Lionel
    SCIENTIFIC REPORTS, 2017, 7
  • [32] Motion of red blood cells in a capillary with an endothelial surface layer: effect of flow velocity
    Secomb, TW
    Hsu, R
    Pries, AR
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2001, 281 (02): : H629 - H636
  • [33] Effects of Ultrapure Hemodialysis and Low Molecular Weight Heparin on the Endothelial Surface Layer
    Cornelis, Tom
    Broers, Natascha J. H.
    Titulaer, Denise C. L. M.
    Henskens, Yvonne M.
    van Oerle, Rene
    van der Sande, Frank M.
    Spronk, Henri M.
    Vink, Hans
    Leunissen, Karel M.
    ten Cate, Hugo
    Kooman, Jeroen P.
    BLOOD PURIFICATION, 2014, 38 (3-4) : 203 - 210
  • [35] Motion and deformation of red blood cells in a capillary with an endothelial surface layer: Effect of flow velocity
    Secomb, TW
    Hsu, R
    Pries, AR
    FASEB JOURNAL, 2000, 14 (04): : A6 - A6
  • [36] Flow-dependent mechanics of red blood cell motion in a capillary with an endothelial surface layer
    Secomb, Timothy W.
    Hsu, Richard
    Pries, Axel R.
    Annals of Biomedical Engineering, 2000, 28 (SUPPL. 1)
  • [37] Effects of Micropatterned Surface of NiTi Alloy on Adhesion of Endothelial Cells and Blood Platelets
    Shen Yang
    Wang Guixue
    Zhang Qin
    Tang Chaojun
    Ge Shuping
    Yu Qingsong
    RARE METAL MATERIALS AND ENGINEERING, 2010, 39 (06) : 1018 - 1022
  • [38] Effects of micropatterned surface of NiTi alloy on adhesion of endothelial cells and blood platelets
    Shen, Yang
    Wang, Guixue
    Zhang, Qin
    Tang, Chaojun
    Ge, Shuping
    Yu, Qingsong
    Xiyou Jinshu Cailiao Yu Gongcheng/Rare Metal Materials and Engineering, 2010, 39 (06): : 1018 - 1022
  • [39] Whole blood-mediated endothelial permeability and adhesion molecule expression: a model study into the effects of bacteria and antibiotics
    Nooteboom, A
    van der Linden, CJ
    Hendriks, T
    JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2005, 55 (02) : 150 - 156
  • [40] Dependence of red blood cell dynamics in microvessel bifurcations on the endothelial surface layer’s resistance to flow and compression
    Carlson Triebold
    Jared Barber