On the Investigation of Autocorrelation-Based Vector Doppler Method With Plane Wave Imaging

被引:13
|
作者
Hasegawa, Hideyuki [1 ]
Omura, Masaaki [1 ]
Nagaoka, Ryo [1 ]
机构
[1] Univ Toyama, Dept Intellectual Informat Syst Engn, Toyama 9308555, Japan
基金
日本学术振兴会;
关键词
Imaging; Acoustics; Doppler effect; Estimation; Autocorrelation; Frequency estimation; Blood flow; Autocorrelation method; blood flow; center frequency; plane wave imaging; vector Doppler; BLOOD-FLOW; TRANSVERSE OSCILLATION; VELOCITY; ULTRASOUND; TRACKING; MOTION;
D O I
10.1109/TUFFC.2022.3152186
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Although color flow imaging is one of the representative applications of the Doppler method, it can estimate only the velocity component in the direction of ultrasonic propagation, that is, the axial velocity component. The vector Doppler method with high-frame-rate plane wave imaging overcomes such a limitation by estimating the blood flow velocity vectors using the axial velocities obtained by emitting plane waves in multiple directions. The autocorrelation technique can be used for the estimation of the axial velocity using the phase shift of an ultrasonic echo signal between two transmit-receive events. The technique also requires the frequency of the received echo signal. Although the center frequency of the emitted ultrasonic signal is commonly used in the estimation of axial velocities, the center frequency should be estimated from the received signals. In this study, a method for the estimation of the center frequency designed particularly for the high-frame-rate plane wave imaging was developed. The proposed method estimates the wavenumbers of the received signal in lateral and vertical directions to estimate the wavenumber in the axial direction, from which the center frequency was estimated. The beam steering angle was also estimated from the wavenumbers in the two directions. The effect of the proposed method was validated in simulations. The absolute bias error (ABE) and root-mean squared error in estimated velocity vectors obtained by plane wave imaging with three beam steering angles (-15 degrees, 0 degrees, and 15 degrees) were reduced from 9.27% and 14.80% to 1.15% and 8.75%, respectively, by the proposed method. The applicability of the proposed method to in vivo measurements was also demonstrated using the in vivo recordings of human common carotid arteries. Physiologically consistent blood flow velocity distributions were obtained with respect to three subjects using the proposed method.
引用
收藏
页码:1301 / 1311
页数:11
相关论文
共 50 条
  • [41] A transcranial multiple waves suppression method for plane wave imaging based on Radon transform
    Pan, Yue
    Qiang, Yu
    Liang, Wenjie
    Huang, Wenyue
    Wang, Ningyuan
    Wang, Xingying
    Zhang, Zhiqiang
    Qiu, Weibao
    Zheng, Hairong
    ULTRASONICS, 2024, 143
  • [42] An EM Imaging Method Based on Plane-Wave Spectrum and Transmission Line Model
    Zhang, Jia-Chen
    Wei, Xingchang
    Ding, Li
    Gao, Xian-Ke
    Xu, Zi-Xiang
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2020, 68 (10) : 4161 - 4168
  • [43] A New Method of Plane-Wave Ultrasound Imaging Based on Reverse Time Migration
    Pan, Yue
    Wang, Xingying
    Qiang, Yu
    Wang, Ningyuan
    Liu, Rong
    Yang, Ge
    Zhang, Zhiqiang
    He, Xiao
    Yu, Yanyan
    Zheng, Hairong
    Qiu, Weibao
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2024, 71 (05) : 1628 - 1639
  • [44] Cascaded Plane Wave Ultrasound for Blood Velocity Vector Imaging in the Carotid Artery
    de Bakker, Joosje M. K.
    de Korte, Chris L.
    Saris, Anne E. C. M.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2024, 71 (03) : 366 - 379
  • [45] Adapting amplitude modulation to plane-wave non-linear Doppler imaging
    Tremblay-Darveau, Charles
    Williams, Ross
    Zhang, Ze
    Milot, Laurent
    Bruce, Matthew
    Burns, Peter N.
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 1742 - 1745
  • [46] Plane-wave based vector flow imaging: beamforming and velocity estimation loads in different processing scenarios
    Lenge, Matteo
    Ramalli, Alessandro
    Ricci, Stefano
    Tortoli, Piero
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [47] Fourier-based beamforming for 3D plane wave imaging and application in vector flow imaging using selective compounding
    Li, Menghan
    Liang, Siyi
    Lu, Minhua
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (18):
  • [48] Data-Decoupled Scattering Imaging Method Based on Autocorrelation Enhancement
    Wang, Chen
    Zhuang, Jiayan
    Ye, Sichao
    Liu, Wei
    Yuan, Yaoyao
    Zhang, Hongman
    Xiao, Jiangjian
    APPLIED SCIENCES-BASEL, 2023, 13 (04):
  • [49] Study on Imaging Method and Doppler Effect for Millimeter Wave Automotive SAR
    Kobayashi, Takumi
    Yamada, Hiroyoshi
    Sugiyama, Yuuichi
    Muramatsu, Shogo
    Yamagchi, Yoshio
    2018 INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION (ISAP), 2018,
  • [50] Accuracy and Precision of Plane Wave Vector Flow Imaging for Laminar and Complex Flow In Vivo
    Jensen, Jonas
    Traberg, Marie Sand
    Hoyos, Carlos Armando Villagomez
    Olesen, Jacob Bjerring
    Tomov, Borislav
    Moshavegh, Ramin
    Stuart, Matthias Bo
    Ewertsen, Caroline
    Hansen, Kristoffer Lindskov
    Nielsen, Michael Bachmann
    Jensen, Jorgen Arendt
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,