Implementation and special considerations for dedicated PET/CT simulation in radiation oncology

被引:0
|
作者
Kearns, W. T. [1 ]
Bourland, J. D. [1 ]
Hinson, W. H. [1 ]
Hampton, C. J. [1 ]
Munley, M. T. [1 ]
机构
[1] Wake Forest Univ, Sch Med, Winston Salem, NC 27109 USA
关键词
D O I
10.1118/1.2760634
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Our radiation oncology department has implemented PET/CT simulation having performed over 125 procedures in the past year. Dedicated PET/CT simulator eliminates the need to fuse outside PET studies and provides scans in the treatment position. However, PET/CT brings special challenges that must be managed to ensure image quality, spatial accuracy, efficient process flow, accurate target definition, and radiation safety. Materials/Methods: In January 2005 our department began providing F‐18 FDG PET/CT simulations on a GE Discovery ST hybrid scanner and GE Advantage Sim software (GE Healthcare, Waukesha WI). Patients were immobilized on a flat table insert, injected, scanned, and had isocenters placed. Phantom studies were performed to ensure spatial accuracy and image quality of the automated fusion software. Studies included measurement of displacement of table height due to patient weight. Due to the time spent adjacent to the patient and the expected high exposure rates, process flow was modified in order to reduce staff exposure. Results/Discussion: Our department was able to confirm spatial accuracy of the automated fusion via phantom studies to meet manufacturer specifications. However, we did reveal a significant table deflection of up to 10mm from the external lasers to the inside bore of the CT scanner which caused a change in scan protocol. Contouring window levels were studied with similar phantoms to determine appropriate settings. Process flow was aided by the hiring of an experienced, certified nuclear medicine technologist to assist the radiation therapists. Additionally, we implemented the process of immobilizing the patient prior to injection to reduce staff exposure. We determined in a separate study dose rates of up to 94μSv/hr at 15 cm from the patient. Conclusion: Dedicated PET/CT simulation in radiation oncology departments is a useful modality, but can add to time and complexity to the simulation workflow. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2398 / 2398
页数:1
相关论文
共 50 条
  • [41] Quantification with a dedicated breast PET/CT scanner
    Bowen, Spencer L.
    Ferrero, Andrea
    Badawi, Ramsey D.
    MEDICAL PHYSICS, 2012, 39 (05) : 2694 - 2707
  • [42] IMPLEMENTATION OF MODULATED LOW DOSE CT FOR PET/CT SCANS TO REDUCE RADIATION DOSE TO PATIENT
    Ng, W.
    Welch, J.
    Pathmaraj, K.
    Scott, A.
    INTERNAL MEDICINE JOURNAL, 2017, 47 : 33 - 33
  • [43] Comprehensive MRI simulation methodology using a dedicated MRI scanner in radiation oncology for external beam radiation treatment planning
    Paulson, Eric S.
    Erickson, Beth
    Schultz, Chris
    Li, X. Allen
    MEDICAL PHYSICS, 2015, 42 (01) : 28 - 39
  • [44] PET and PET/CT in Pediatric Gastrointestinal Tract Oncology
    Chamroonrat, Wichana
    Houseni, Mohamed
    Li, Geming
    Alavi, Abass
    Zhuang, Hongming
    PET CLINICS, 2008, 3 (02) : 227 - +
  • [45] PET/CT and PET/MRI in ophthalmic oncology (Review)
    Kalemaki, Maria S.
    Karantanas, Apostolos H.
    Exarchos, Dimitris
    Detorakis, Efstathios T.
    Zoras, Odysseas
    Marias, Kostas
    Millo, Corina
    Bagci, Ulas
    Pallikaris, Ioannis
    Stratis, Andreas
    Karatzanis, Ioannis
    Perisinakis, Kostas
    Koutentakis, Pavlos
    Kontadakis, Georgios A.
    Spandidos, Demetrios A.
    Tsatsakis, Aristidis
    Papadakis, Georgios Z.
    INTERNATIONAL JOURNAL OF ONCOLOGY, 2020, 56 (02) : 417 - 429
  • [46] The Impact of PET/CT on Paediatric Oncology
    Brink, Anita
    Hlongwa, Khanyisile N.
    More, Stuart
    DIAGNOSTICS, 2023, 13 (02)
  • [47] PET-CT in clinical oncology
    Maldonado, A.
    Gonzalez-Alenda, F. J.
    Alonso, M.
    Sierra, J. M.
    CLINICAL & TRANSLATIONAL ONCOLOGY, 2007, 9 (08): : 494 - 505
  • [48] New perspectives of PET/CT in oncology
    Garcia Vicente, A. M.
    Soriano Castrejon, A.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2013, 37 (03): : 88 - 92
  • [49] Is PET/CT necessary in paediatric oncology? For
    Franzius, Christiane
    Schober, Otmar
    Juergens, Kai Uwe
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 (08) : 960 - 965
  • [50] Assessing patient comfort with flat-top radiation oncology palette vs. standard PET/CT table in PET/CT
    Hurley, Deborah
    Hall, Nathan
    Knopp, Michael
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50