Decreasing Radiation Exposure in Pediatric Clavicle and Metatarsal Fractures: A QI Initiative

被引:7
|
作者
Brown, Zoe [1 ]
Perry, Michael [2 ]
Wozniak, Amy W. [3 ]
Cappello, Teresa [4 ]
机构
[1] Loyola Univ Chicago, Stritch Sch Med, Maywood, IL USA
[2] Loyola Univ Chicago, Clin Res Off Biostat Core, Chicago, IL USA
[3] Shriners Hosp Children, Dept Orthopaed Surg, Chicago, IL USA
[4] Scripps Clin, Dept Orthopaed Surg, La Jolla, CA 92037 USA
关键词
clavicle; metatarsal; fracture; nonoperative management; radiographic examination; children; adolescents;
D O I
10.1097/BPO.0000000000001725
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Protecting the pediatric population from unnecessary medical radiation is an important public health initiative. Efforts have been made to reduce radiation exposure in the treatment of pediatric fractures without compromising quality of care. Using a standardized protocol for imaging of pediatric clavicle and metatarsal fractures is a reliable method for reducing pediatric radiation exposure in the management of these fractures. Methods: In the year 2015, the senior author altered follow-up imaging practices for 2 common pediatric fractures: metatarsal and clavicular. Initial radiographic evaluation included the standard 3 views for metatarsal fractures and 2 views for clavicle fractures. This standard diagnostic procedure remained constant throughout the study. Follow-up x-rays from 2009 to 2014 routinely included 3 views of the foot and 2 views of the clavicle. The protocol was changed and from 2016 to 2019, follow-up x-rays for fractures routinely included 2 views of the foot and 1 view of the clavicle, thereby decreasing the number of x-rays utilized to manage these fractures. Results: There was a significant reduction in the number of clavicle x-rays (P<0.001) and metatarsal x-rays (P=0.004) taken in follow-up between the time-periods. Median values for metatarsal views decreased by 1, matching the adjustment in protocol. In addition, the vast majority of clavicle fractures (90.80%) were managed with 1 follow-up view in 2016 to 2019 compared with 2 views (72.48%) from 2009 to 2014. Conclusions: This study achieved a reduction in radiation exposure in pediatric patients with nonoperatively managed clavicle and metatarsal fractures. Improving the quality of care of patients through decreasing the number of x-rays taken protects individuals from adverse side effects, as well as offers various public health benefits in terms of reduction in expenditures.
引用
收藏
页码:177 / 181
页数:5
相关论文
共 50 条
  • [41] Evaluation of an initiative to reduce radiation exposure from CT to children in a non-pediatric-focused facility
    Blumfield E.
    Zember J.
    Guelfguat M.
    Blumfield A.
    Goldman H.
    Emergency Radiology, 2015, 22 (6) : 631 - 641
  • [42] Radiation Exposure During Operative Fixation of Pediatric Supracondylar Humerus Fractures: Is Lead Shielding Necessary?
    Martus, Jeffrey E.
    Hilmes, Melissa A.
    Grice, Jared V.
    Stutz, Christopher M.
    Schoenecker, Jonathan G.
    Lovejoy, Steven A.
    Mencio, Gregory A.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2018, 38 (05) : 249 - 253
  • [43] EXPOSURE TO RADIATION AND RADIATION RISKS IN PEDIATRIC CARDIOLOGY
    BORCHERS, HD
    LOHR, H
    KECK, EW
    LASSRICH, MA
    HERZ KREISLAUF, 1980, 12 (09): : 414 - 414
  • [44] Shields and garb for decreasing radiation exposure in the cath lab
    Karatasakis, Aris
    Brilakis, Emmanouil S.
    EXPERT REVIEW OF MEDICAL DEVICES, 2018, 15 (09) : 683 - 688
  • [45] Decreasing Radiation Exposure to the Abdomen in Children with Chronic Constipation
    Chun, Bennet C.
    Chmil, Margarita
    Ruess, Lynne
    PEDIATRIC QUALITY & SAFETY, 2023, 8 (05) : E681
  • [46] Radiation osteitis and fractures following irradiation - With report of five cases of fractured clavicle
    Slaughter, DP
    AMERICAN JOURNAL OF ROENTGENOLOGY AND RADIUM THERAPY, 1942, 48 : 201 - 212
  • [47] High Reliability Pediatric Septic Shock Quality Improvement Initiative and Decreasing Mortality
    Lane, Roni D.
    Funai, Tomohiko
    Reeder, Ron
    Larsen, Gitte Y.
    PEDIATRICS, 2016, 138 (04)
  • [48] Variation in Treatment Approaches to Adolescent Midshaft Clavicle Fractures in Pediatric Versus Adult Hospitals
    Zhang, Dafang
    Heyworth, Benton E.
    Liotta, Elizabeth S.
    Hergott, Katelyn A.
    Earp, Brandon E.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2021, 35 (05) : 271 - 275
  • [49] Reducing radiation exposure in pediatric cervical spine imaging for trauma: a multi-disciplinary quality improvement initiative
    Yu, Nina
    Kohler, Jonathan Emerson
    Grether-Jones, Kendra
    Murphy, Maureen
    Zwienenberg, Marike
    CHILDS NERVOUS SYSTEM, 2025, 41 (01)
  • [50] The Effect of C-Arm Position on Radiation Exposure During Fixation of Pediatric Supracondylar Fractures of the Humerus
    Hsu, Raymond Y.
    Lareau, Craig R.
    Kim, Jeom Soon
    Koruprolu, Sarath
    Born, Christopher T.
    Schiller, Jonathan R.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (15): : e129(1)