Voltammetric behavior of peptide-modified porous silicon after metal complexation

被引:0
|
作者
Sam, Sabrina [1 ]
Gouget-Laemmel, Anne Chantal [2 ]
Chazalviel, Jean-Noel [2 ]
Ozanam, Francois [2 ]
Etcheberry, Arnaud [3 ]
Belhousse, Samia [1 ]
Gabouze, Noureddine [1 ]
机构
[1] Ctr Rech Technol Semicond Energet CRTSE, Algiers, Algeria
[2] Ecole Polytech, UMR CNRS 7643, LPMC, F-91128 Palaiseau, France
[3] Inst Lavoisier Versailles, UMR CNRS 8180, Versailles, France
关键词
Hybrid materials; Porous silicon; Functionalization; Metal detection; POTENTIAL SWEEP VOLTAMMOGRAM; MODIFIED ELECTRODES; GENERAL EXPRESSION; MONOLAYERS;
D O I
10.4028/www.scientific.net/KEM.605.119
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Hybrid nanomaterials based on organic layer covalently grafted on porous silicon (PSi) nanostructure appear as promising systems for innovative applications such as detecting of traces amounts and/or removing metal cations in water effluents. In this work, we focused on the functionalization of the PSi nanostructure by the peptide GlyCysGlyCys, which forms stable complexes with metal ions. This property is exploited to achieve toxic metal recognition in water using electrochemical methods. Peptide immobilization was achieved using multi-step reactions; GlyCysGlyCys was anchored on a previously prepared carboxyl-terminated PSi surface, using EDC/NHS coupling agents. This scheme is compatible with the mild conditions required for preserving the probe activity of the peptide. At each step of the functionalization, the surface was monitored by Fourier transform infrared spectroscopy (FTIR) and X-ray photoelectron spectroscopy (XPS). Electrochemical behavior of such modified electrode was carried out after Nickel accumulation on the surface, by means of cyclic voltammetry. The recorded cyclic voltammograms showed a quasi-irreversible process corresponding to the Ni2+/Ni-0 couple.
引用
收藏
页码:119 / 122
页数:4
相关论文
共 42 条
  • [31] Comparative fabrication and performance of metal-semiconductor-metal and heterojunction near-infrared photodetectors using Ag-modified porous silicon
    Abdulgafar, Sayran A.
    Ibrahem, Mohammed A.
    Slewa, Lary H.
    MICRO AND NANOSTRUCTURES, 2025, 202
  • [32] Room temperature metal-insulator-semiconductor (MIS) hydrogen sensors based on chemically surface modified porous silicon
    Kanungo, J.
    Saha, H.
    Basu, S.
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 140 (01) : 65 - 72
  • [33] The Machine Learning-Guided Fit4Function Platform Quantitatively Profiles the Biodistribution of Peptide-Modified AAV Capsids after a Single Round of Screening in Macaque
    Eid, Fatma Elzahraa
    Chen, Albert
    Chan, Ken
    Huang, Qin
    Zheng, Qingxia
    Tobey, Isabelle
    Pacouret, Simon
    Brauer, Pamela
    Keyes, Casey
    Powell, Megan
    Johnston, Jencilin
    Zhao, Binhui
    Tarantal, Alice
    Chan, Yujia A.
    Deverman, Benjamin
    MOLECULAR THERAPY, 2023, 31 (04) : 42 - 43
  • [34] VOLTAMMETRIC AND ELECTROCHROMIC BEHAVIOR OF N-HEPTYLVIOLOGEN FILMS ON CHEMICALLY MODIFIED METAL-OXIDE ELECTRODES AND METALLIZED-PLASTIC ELECTRODE FILMS
    CIESLINSKI, RC
    ARMSTRONG, NR
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1979, 126 (08) : C356 - C356
  • [35] Indirect differential pulse voltammetric analysis of cyanide at porous copper based metal organic framework modified carbon paste electrode: Application to different water samples
    Mahmoud, Ashraf M.
    Mahnashi, Mater H.
    El-Wekil, Mohamed M.
    TALANTA, 2021, 221
  • [36] Selective modified stripping voltammetric sensor based on Ce-1,4-benzenedicarboxylic metal-organic frameworks porous nanoparticles for picomolar detection of curcumin
    Elfiky, Mona
    Beltagi, Amr M.
    Abuzalat, Osama
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 898
  • [37] Metal acetylacetonate domains grown on H-terminated porous silicon at room temperature and their specific I-V behavior
    Chao, Jie
    Wang, Hai-Tao
    Xia, Bing
    Liu, Hong-Bo
    Xiao, Zhong-Dang
    Xiao, Shou-Jun
    JOURNAL OF PHYSICAL CHEMISTRY B, 2006, 110 (48): : 24565 - 24570
  • [38] A novel modified graphite paste sensor based on porous Sn-1,4-benzenedicarboxylate metal-organic frameworks for stripping voltammetric detection of 5-fluorouracil drug
    Elfiky, Mona
    Elleboudy, Aya E.
    Salahuddin, Nehal
    MICROCHEMICAL JOURNAL, 2023, 192
  • [39] Silicon containing structures at interfaces: The wetting behavior of carbohydrate modified Si surfactants on perfluorinated surfaces and the modification of rough metal surfaces by hydrophilic polysiloxane networks
    Wagner, R
    Wu, YL
    Richter, L
    Pfohl, T
    Siegel, S
    Weissmuller, J
    Reiners, J
    Stelzle, M
    Frohlich, R
    CHEMICAL ENGINEERING & TECHNOLOGY, 1998, 21 (02) : 172 - +
  • [40] Silicon Containing Structures at Interfaces: The Wetting Behavior of Carbohydrate Modified Si Surfactants on Perfluorinated Surfaces and the Modification of Rough Metal Surfaces by Hydrophilic Polysiloxane Networks
    Wagner, Roland
    Wu, Yuling
    Richter, Lothar
    Pfohl, Thomas
    Siegel, Stefan
    Weißmüller, Joachim
    Reiners, Jürgen
    Stelzle, Martin
    Fröhlich, Ronald
    Chemical Engineering and Technology, 1998, 21 (02): : 172 - 174