Feasibility of simultaneous 99mTc-tetrofosmin and 123I-BMIPP dual-tracer imaging with cadmium-zinc-telluride detectors in patients undergoing primary coronary intervention for acute myocardial infarction

被引:9
|
作者
Yamada, Yoshihiro [1 ]
Nakano, Shintaro [1 ]
Gatate, Youdou [1 ]
Okano, Nanami [2 ]
Muramatsu, Toshihiro [1 ]
Nishimura, Shigeyuki [1 ]
Kuji, Ichiei [3 ]
Fukushima, Kenji [3 ]
Matsunari, Ichiro [2 ]
机构
[1] Saitama Med Univ, Dept Cardiol, Int Med Ctr, 1397-1 Yamane, Saitama 3501298, Japan
[2] Saitama Med Univ, Dept Radiol, Div Nucl Med, Saitama, Japan
[3] Saitama Med Univ, Int Med Ctr, Dept Nucl Med, Saitama, Japan
关键词
Perfusion-metabolism mismatch; CZT camera; acute myocardial infarction; dual imaging;
D O I
10.1007/s12350-018-01585-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Simultaneous dual-tracer imaging using isotopes with close photo-peaks may benefit from improved properties of cadmium-zinc-telluride (CZT)-based scanners. Methods Thirty patients having undergone primary percutaneous coronary intervention for acute myocardial infarction underwent single-(Tc-99m-tetrofosmin (TF) or I-123-BMIPP first) followed by simultaneous Tc-99m-TF /I-123-BMIPP dual-tracer imaging using a Discovery NM/CT 670 CZT. The values for the quantitative gated-SPECT (QGS) and the quantitative perfusion SPECT (QPS) were assessed. Results The intra-class correlation (ICC) coefficients between the single- and dual-tracer imaging were high in all the QGS and QPS data (Summed motion score: 0.95, summed thickening score: 0.94, ejection fraction: 0.98, SRS for Tc-99m-TF: 0.97/ for I-123-BMIPP: 0.95). Wall motion, wall thickening and rest scores per coronary-territory-based regions were also comparable between the single- and dual imaging (ICC coefficient > 0.91). The interrater concordance in the visual analysis for the infarction and perfusion-metabolism mismatch was significant for the global and regional left ventricle (P < 0.001). Conclusion The quantitative/semi-quantitative values for global and regional left-ventricular function, perfusion, and fatty acid metabolism were closely comparable between the dual-tracer imaging and the single-tracer mode. These data suggests the feasibility of the novel CZT-based scanner for the simultaneous Tc-99m-TF /I-123-BMIPP dual-tracer acquisitions in clinical settings.
引用
收藏
页码:187 / 195
页数:9
相关论文
共 24 条
  • [11] Difference between 99mTc-Sestamibi and 123I-BMIPP myocardial washout rates in patients with acute myocardial infarction
    Ashikaga, K.
    Akashi, Y. J.
    Kamijima, R.
    Uematsu, M.
    Yoneyama, K.
    Kida, K.
    Suzuki, K.
    Omiya, K.
    Miyake, Y.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2011, 13 (0A) : A56 - A56
  • [12] Incremental predictive value of myocardial scintigraphy with 123I-BMIPP in patients with acute myocardial infarction treated with primary percutaneous coronary intervention
    Nanasato, M
    Hirayama, H
    Ando, A
    Isobe, S
    Nonokawa, M
    Kinoshita, Y
    Nanbu, I
    Yokota, M
    Murohara, T
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 (11) : 1512 - 1521
  • [13] Incremental predictive value of myocardial scintigraphy with 123I-BMIPP in patients with acute myocardial infarction treated with primary percutaneous coronary intervention
    Mamoru Nanasato
    Haruo Hirayama
    Akitada Ando
    Satoshi Isobe
    Makoto Nonokawa
    Yoshimi Kinoshita
    Ichiro Nanbu
    Mitsuhiro Yokota
    Toyoaki Murohara
    European Journal of Nuclear Medicine and Molecular Imaging, 2004, 31 : 1512 - 1521
  • [14] REDUCING STUDY TIME FOR REST/STRESS 99MTC-TETROFOSMIN MYOCARDIAL PERFUSION IMAGING WITH MYOCARDIAL BLOOD FLOW MEASUREMENT USING CADMIUM-ZINC-TELLURIDE CAMERA IMAGING
    Kadoya, Yoshito
    Naji, Khalid
    Chow, Benjamin J. W.
    Small, Gary R.
    Wells, R. Glenn
    Ruddy, Terrence D.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 1448 - 1448
  • [15] Determination of the Heart-to-Mediastinum Ratio of 123I-MIBG Uptake Using Dual-Isotope (123I-MIBG/99mTc-Tetrofosmin) Multipinhole Cadmium-Zinc-Telluride SPECT in Patients with Heart Failure
    Blaire, Tanguy
    Bailliez, Alban
    Ben Bouallegue, Faycal
    Bellevre, Dimitri
    Agostini, Denis
    Manrique, Alain
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (02) : 251 - 258
  • [16] Prediction of myocardial viability in chronic phase in patients with acute myocardial infarction by simultaneous dual-isotope imaging with 99mTc-sestamibi/123I-BMIPP SPECT using CZT camera system
    Fujita, Y.
    Hida, S.
    Igarashi, Y.
    Hatano, T.
    Morishima, T.
    Yamashita, J.
    Murata, N.
    Ito, R.
    Chikamori, T.
    EUROPEAN HEART JOURNAL, 2020, 41 : 277 - 277
  • [17] Simultaneous myocardial Tc-99m/I-123 imaging using a cadmium-zinc-telluride camera: Validation of triglyceride deposit cardiomyopathy diagnosis
    Niimi, T.
    Sugimoto, M.
    Unno, K.
    Yoshida, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S203 - S203
  • [18] Diagnostic value of simultaneous 99mTc-sestamibi/123I-BMIPP imaging parameters for predicting the improvement of left ventricular wall motion after acute myocardial infarction using CZT SPECT system
    Hida, S.
    Fujita, Y.
    Hatano, T.
    Morishima, T.
    Yamashita, J.
    Murata, N.
    Ito, R.
    Chikamori, T.
    EUROPEAN HEART JOURNAL, 2021, 42 : 253 - 253
  • [19] Ischemic "memory image" in acute myocardial infarction of 123I-BMIPP after reperfusion therapy:: A comparison with 99mTc-pyrophosphate and 201Tl dual-isotope SPECT
    Mochizuki, T
    Murase, K
    Higashino, H
    Miyagawa, M
    Sugawara, Y
    Kikuchi, T
    Ikezoe, J
    ANNALS OF NUCLEAR MEDICINE, 2002, 16 (08) : 563 - 568
  • [20] 123I-BMIPP/99m-Tc SPECT mismatch after primary percutaneous coronary intervention is strongly associated with functional recovery only in anterior ST segment elevation myocardial infarction
    Shibata, H.
    Yamada, S.
    Taniguchi, Y.
    Iwata, S.
    Shimane, A.
    Takaya, T.
    Miyoshi, N.
    Yokoi, K.
    Hayashi, T.
    EUROPEAN HEART JOURNAL, 2011, 32 : 734 - 734