Pulsed UV lamp performance and comparison with UV mercury lamps

被引:0
|
作者
Schaefer, Raymond
Grapperhaus, Michael
Schaefer, Ian
Linden, Karl
机构
[1] Phoenix Sci & Technol Inc, Chelmsford, MA 01824 USA
[2] Duke Univ, Dept Civil & Environm Engn, Durham, NC 27708 USA
关键词
pulsed UV; water treatment; flashlamp; surface discharge; mercury;
D O I
10.1139/S06-068
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Pulsed lamps based on electric discharges in xenon are of interest for water treatment because they are free of mercury, have instant-on capability, and may provide enhanced effects due to the high irradiance of pulses or spectral differences. This study provides quantitative comparisons of standard mercury UV lamps with both a commercial flashlamp and a pulsed surface discharge lamp. Unlike mercury lamps, the UV performance of pulsed lamps is a function of operating parameters. In this study the measured UV efficiency of a flashlamp, with a specified. practical lifetime, increased as the pulse length decreased, from 4.4% at 796 mu s to 9.0% at 71 mu s. The surface discharge lamp, which overcomes limitations of flashlamps, had a measured UV efficiency of 17% at 12 tts. In comparison, standard commercial low pressure and medium pressure mercury lamps evaluated in this study had UV efficiencies of 34.6% and 12.2%, respectively.
引用
收藏
页码:303 / 310
页数:8
相关论文
共 50 条
  • [31] Recent progress on UV lamps for industries
    Morimoto, Y
    Sumitomo, T
    Yoshioka, M
    Takemura, T
    CONFERENCE RECORD OF THE 2004 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4: COVERING THEORY TO PRACTICE, 2004, : 1008 - 1015
  • [32] UV-A Lamps Ideal for Inspection
    Miskinyar, Husna
    MATERIALS PERFORMANCE, 2015, 54 (04) : 26 - 26
  • [33] POSSIBLE RISKS BY UV-LAMPS
    SWANBECK, G
    HAUTARZT, 1984, 35 (04): : 173 - 174
  • [34] History of UV Lamps, Types, and Their Applications
    Ahmad, Shamim I.
    Christensen, Luisa
    Baron, Elma
    ULTRAVIOLET LIGHT IN HUMAN HEALTH, DISEASES AND ENVIRONMENT, 2017, 996 : 3 - 11
  • [35] Control systems for the operation of UV lamps
    Beying, A
    RADTECH'98 NORTH AMERICA UV/EB CONFERENCE PROCEEDINGS, 1998, : 117 - 119
  • [36] Comparison of sterilization efficiency of pulsed and continuous UV light using tunable frequency UV system
    Luo, Wei
    Chen, Anjun
    Chen, Min
    Dong, Wei
    Hou, Xiaoyan
    INNOVATIVE FOOD SCIENCE & EMERGING TECHNOLOGIES, 2014, 26 : 220 - 225
  • [37] Pulsed UV output
    Srikanth, G
    PHOTONICS SPECTRA, 2005, 39 (08) : 52 - 52
  • [38] High intensity UV emission from cold-cathode mercury-argon lamps
    Kobayashi, Shinji
    Murata, Takaaki
    Terai, Kiyohisa
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 1999, 38 (7 B): : 4605 - 4607
  • [39] Photochemical treatment of water: Comparison of incoherent excimer lamps with a medium-pressure mercury lamp
    Oppenlander, T
    CHEMICAL ENGINEERING & TECHNOLOGY, 1998, 21 (06) : 502 - 505
  • [40] High intensity UV emission from cold-cathode mercury-argon lamps
    Kobayashi, S
    Murata, T
    Terai, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1999, 38 (7B): : 4605 - 4607