Orbital Plates and Screws Causing Globe Fixation: A Rare and Delayed Complication of Craniomaxillofacial Surgery

被引:2
|
作者
Chandra, Varun [1 ]
Buck, Danielle [1 ]
Chakrabarti, Rahul [1 ]
McNab, Alan [1 ,2 ,3 ]
机构
[1] Royal Victorian Eye & Ear Hosp, Orbital Plast & Lacrimal Clin, East Melbourne, Vic, Australia
[2] Ctr Eye Res Australia, East Melbourne, Vic, Australia
[3] Univ Melbourne, Dept Ophthalmol, Melbourne, Vic, Australia
来源
关键词
D O I
10.1097/IOP.0000000000001097
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
A 24-year-old woman presented with a 1-year history of gradually increasing pain on eye movements, worse on the right. She had a significant background of undergoing intracranial correction of orbital hypertelorism with internal fixation of the lateral orbital rims at the age of 6 years. Imaging was consistent with bilateral metallic foreign bodies from both lateral orbital rims protruding into the globes. The patient underwent removal of bilateral plates and screws, with a significant improvement of symptoms and ocular motility postoperatively. This case demonstrates the need to consider orbital screw/plate migration in the setting of reduced ocular motility and painful eye movements.