Simultaneous determination of imidazolinone herbicides from soil and natural waters using soil column extraction and off-line solid-phase extraction followed by liquid chromatography with UV detection or liquid chromatography electrospray mass spectroscopy

被引:40
|
作者
Laganà, A [1 ]
Fago, C [1 ]
Marino, A [1 ]
机构
[1] Univ Rome La Sapienza, Dept Chem, I-00185 Rome, Italy
关键词
D O I
10.1021/ac9707491
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes the simultaneous quantification of the imidazolinone herbicides (IMIs) imazapyr, m-imazamethabenz, p-imazamethabenz, m,p-imazamethabenzmethyl, imazethapyr, and imazaquin in two types of samples, (a) Groundwater, lake water, and river water samples were enriched by off-line solid-phase extraction with a Carbograph-1 cartridge and analyzed by reversed-phase liquid chromatography using a UV detector (lambda, = 240 nm). The overall recoveries of IMIs extracted from 1 L of groundwater (fortified with 500-100 ng/L), 0.5 L of lake water (fortified with 500-100ng/L), and 0.5 L of liver water (fortified with 1000-200 ng/L) samples were not lower than 89%, The mean relative standard deviation (RSD) was 5.1% (ranging from 4.1% to 6.8%) in natural water, The detection limits were 30-39 ng/L in groundwater, 43-51 ng/L in lake water, and 55-67 ng/L in river water, The method involves confirmatory analysis by LC/ES-MS in full-scan mode, The dependence of the ion signal intensities on proton concentration in the mobile phase was investigated with a view to optimizing the sensitivity of the ES-MS detector, When LC/ES-MS was used, the limit of detection, calculated from extracted-ion current profiles (EICPs), was 4-7 ng/L for groundwater and 9-13 ng/L for river water, (b) Soil sample analysis utilized combined soil column extraction (SCE) and off-line solid phase extraction (SPE) for sample preparation, analyzing with LC/ES-MS under selected ion monitoring (SIM), Several different extractants were evaluated for the purpose of SCE optimization, The system that best optimizes the extractability IMIs from the soil was found to be the mixture CH3OH/(NH4)(2)CO3 (0.1 M, 50:50 v/v), The effect of IMI concentration in the matrix on recovery was evaluated, The total recovery of each IMI from soil at each of the two levels investigated ranged from 87% to 95%, Under three ion SIM conditions, the limit of detection (S/N = 3) was 0.1-0.05 ng/g in soil samples.
引用
收藏
页码:121 / 130
页数:10
相关论文
共 50 条
  • [21] Determination of phenylurea herbicides in river water by monolithic solid-phase extraction and rapid resolution liquid chromatography with UV detection
    Lin, Shu-Ling
    Fuh, Ming-Ren
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 243
  • [22] Trace analysis of sulfonylurea herbicides and their metabolites in water using a combination of off-line or on-line solid-phase extraction and liquid chromatography-tandem mass spectrometry
    Perreau, Francois
    Bados, Philippe
    Kerhoas, Lucien
    Nelieu, Sylvie
    Einhorn, Jacques
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 388 (5-6) : 1265 - 1273
  • [23] Simultaneous determination of twelve natural estrogens in dairy milk using liquid–liquid extraction and solid-phase extraction coupled with gas chromatography-mass spectrometry
    De-ming Kong
    Zhao Tang
    Ze-hua Liu
    Zhi Dang
    Peng-ran Guo
    Yu-mei Song
    Yu Liu
    Environmental Science and Pollution Research, 2023, 30 : 112908 - 112921
  • [24] DETERMINATION OF ADENOSINE AND INOSINE IN SHEEP PLASMA USING SOLID PHASE EXTRACTION FOLLOWED BY LIQUID CHROMATOGRAPHY WITH UV DETECTION
    Chitta, Rajesh
    Pendela, Murali
    Yekkala, Raja
    Herijgers, Paul
    Hoogmartens, Jos
    Adams, Erwin
    ANALYTICAL LETTERS, 2010, 43 (14) : 2267 - 2274
  • [25] Determination of pentachlorophenol in certified waste waters, soil samples and industrial effluents using ELISA and liquid solid extraction followed by liquid chromatography
    Oubina, A
    Puig, D
    Gascon, J
    Barcelo, D
    ANALYTICA CHIMICA ACTA, 1997, 346 (01) : 49 - 59
  • [26] Determination of epitestosterone in human urine by off-line immunoaffinity solid-phase extraction coupled with high performance liquid chromatography
    Xu, Li
    Qiu, Shuang
    Sun, Cui-Jin
    Deng, Qin-Pei
    Chen, Hong-Xu
    Zhou, Ying-Lin
    Zhang, Xin-Xiang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (19): : 1443 - 1448
  • [27] Determination of maize and grain herbicides and their transformation products in soil by use of soil column extraction then liquid chromatography with tandem mass spectrometry
    A. Laganà
    A. Bacaloni
    I. De Leva
    A. Faberi
    G. Fago
    A. Marino
    Chromatographia, 2002, 56 : 337 - 343
  • [28] Determination of maize and grain herbicides and their transformation products in soil by use of soil column extraction then liquid chromatography with tandem mass spectrometry
    Laganà, A
    Bacaloni, A
    De Leva, I
    Faberi, A
    Fago, G
    Marino, A
    CHROMATOGRAPHIA, 2002, 56 (5-6) : 337 - 343
  • [29] Determination of several pesticides in water by solid-phase extraction, liquid chromatography and electrospray tandem mass spectrometry
    Rodrigues, Alexandre Mourao
    Ferreira, Vera
    Cardoso, Vitor Vale
    Ferreira, Elisabete
    Benoliel, Maria Joao
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1150 (1-2) : 267 - 278
  • [30] Routine determination of sulfonylurea, imidazolinone, and sulfonamide herbicides at nanogram-per-liter concentrations by solid-phase extraction and liquid chromatography/mass spectrometry
    Furlong, ET
    Burkhardt, MR
    Gates, PM
    Werner, SL
    Battaglin, WA
    SCIENCE OF THE TOTAL ENVIRONMENT, 2000, 248 (2-3) : 135 - 146