Interruption in Air for Different Medium-Voltage Switching Duties

被引:10
|
作者
Jonsson, Erik [1 ]
Runde, Magne [2 ]
机构
[1] Norwegian Univ Sci & Technol NTNU, Dept Elect Power Engn, NO-7491 Trondheim, Norway
[2] SINTEF Energy Res, NO-7465 Trondheim, Norway
关键词
Air; current interruption; current zero; load break switch; medium-voltage (MV) switchgear; puffer; thermal interruption; GASES;
D O I
10.1109/TPWRD.2014.2345129
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Air is an environmentally benign alternative to SF for use in medium-voltage load-break switches. A simple, axisymmetric test switch has been used for empirical studies of the thermal phase of current interruption in atmospheric air. The purpose is to quantify how the pressure drop across the nozzle influences the interrupting capability at a different rate of rise of the recovery voltages (RRRVs) and with different current amplitudes. Tests with pressure drops in the range 0.1-1.1 bar, RRRVs of 40, 80, and 160 V/mu s, and currents of 300, 600, and 900 A were carried out. In general, the current that can be successfully interrupted is proportional with the pressure drop. Likewise, a steeper RRRV requires a proportionally higher pressure drop for the interruption to be successful. For compact air load-break switches for the important 24 kV/630-A class, it seems sufficient to provide a pressure drop of around 0.25 bar lasting for at least 20 ms to comply with the "mainly active load" test-type requirements.
引用
下载
收藏
页码:161 / 166
页数:6
相关论文
共 50 条
  • [21] Comparison of 2.3-kV medium-voltage multilevel converters for industrial medium-voltage drives
    Krug, Dietmar
    Bernet, Steffen
    Fazel, Seyed Saeed
    Jahli, Kamran
    Malinowski, Mariusz
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2007, 54 (06) : 2979 - 2992
  • [22] Common-Mode Voltage Reduction for Medium-Voltage Current Source Converters by Optimizing Switching Sequences
    Hu, Anping
    Zhu, Ning
    Xu, Dewei
    Wu, Bin
    Su, Jianhui
    2013 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2013, : 837 - 843
  • [23] Analysis and Mitigation on Switching Transients of Medium-Voltage Low-Harmonic Filter Banks
    Kim, Joon-Ho
    Kim, Jin-O
    ENERGIES, 2020, 13 (09)
  • [24] Low-Switching-Frequency Active Damping Methods of Medium-Voltage Multilevel Inverters
    Ricchiuto, D.
    Liserre, M.
    De Santis, D.
    2012 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2012, : 1991 - 1996
  • [25] Impact of Power Module Parasitic Capacitances on Medium-Voltage SiC MOSFETs Switching Transients
    Dalal, Dipen Narendra
    Christensen, Nicklas
    Jorgensen, Asger Bjorn
    Jorgensen, Jannick Kjaer
    Beczkowski, Szymon
    Munk-Nielsen, Stig
    Uhrenfeldt, Christian
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2020, 8 (01) : 298 - 310
  • [26] Modeling a Switching-Regulated Capacitively Coupled Power Supply for Medium-Voltage AC
    Carlos Rodriguez, Juan
    Grijalva, Felipe
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2022, 10 (01) : 52 - 60
  • [27] SWITCHING PHENOMENA IN MEDIUM-VOLTAGE POWER-SYSTEMS AND THEIR CONSIDERATION IN PROJECT-PLANNING
    BALZER, G
    BROWN BOVERI REVIEW, 1986, 73 (05): : 270 - 278
  • [28] A New Topology for Medium-Voltage Applications
    Chen, Guo
    Narimani, Mehdi
    2018 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2018, : 5230 - 5234
  • [29] DEVELOPMENT TRENDS IN MEDIUM-VOLTAGE SWITCHGEAR
    PAULS, H
    HACKENSCHMIDT, K
    BROWN BOVERI REVIEW, 1986, 73 (11): : 621 - 628
  • [30] Benchmarking the reliability of medium-voltage lines
    Kolcun, Michal
    Kornatka, Miroslaw
    Gawlak, Anna
    Conka, Zsolt
    JOURNAL OF ELECTRICAL ENGINEERING-ELEKTROTECHNICKY CASOPIS, 2017, 68 (03): : 212 - 215