Biodegradable-Polymer Versus Polymer-Free Drug-Eluting Stents for the Treatment of Coronary Artery Disease

被引:9
|
作者
Nogic, Jason [1 ,2 ]
Thein, Paul [1 ,2 ]
Mirzaee, Sam [1 ,2 ]
Comella, Andrea [1 ,2 ]
Soon, Kean [3 ]
Cameron, James D. [1 ,2 ]
West, Nick E. J. [4 ]
Brown, Adam J. [1 ,2 ]
机构
[1] Monash Univ, Monash Cardiovasc Res Ctr, Melbourne, Vic, Australia
[2] Monash Hlth, MonashHeart, 246 Clayton Rd, Melbourne, Vic, Australia
[3] Eastern Hlth, Dept Cardiol, Melbourne, Vic, Australia
[4] Royal Papworth Hosp, Dept Intervent Cardiol, Cambridge, England
关键词
Drug-eluting stent; Biodegradable-polymer stent; Polymer-free stent; Coronary artery disease; Percutaneous coronary intervention; BARE-METAL STENTS; COATING STRATEGIES; CLINICAL-OUTCOMES; RANDOMIZED-TRIAL; METAANALYSIS; MULTICENTER; RESTENOSIS; RESPONSES;
D O I
10.1016/j.carrev.2018.12.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/purpose: Biodegradable-polymer (BP) and polymer-free (PF) drug eluting stents (DES) were developed to reduce the risk of delayed arterial healing observed with durable-polymer (DP) platforms. Although trials demonstrate BP-DES and PF-DES are non-inferior to DP-DES, there is limited data directly comparing these technologies. We performed a meta-analysis to assess the efficacy and safety of BP-DES versus PF-DES for the treatment of coronary artery disease. Methods/materials: Electronic searches were performed identifying randomized trials comparing BP-DES with PF-DES. Co-primary efficacy endpoints were target vessel revascularization (TVR), target lesion revascularization (TLR) and angiographic in-stent late lumen loss (LLL). Co-secondary safety endpoints were all-cause death, myocardial infarction (MI) and stent thrombosis (ST). Results: Of 208 studies, 5 met inclusion criteria including 1975 patients. At mean follow-up (14 +/- 5months), BP-DES were associated with significantly reduced rates of TVR (OR 0.58, 95%CI 0.37-0.92, p = 0.02), TLR (4.7% vs 9.5%) (OR 0.48, 95%CI 0.31-0.75, p = 0.001) and in-stent LLL (pooled mean difference -0.20 mm, 95%CI -0.24 to -0.16, p < 0.001). There was no difference in safety, including all-cause death (OR 1.24, 95%CI 0.68-2.28, p = 0.48), MI (OR 0.92, 95%CI 0.54-1.56, p = 0.75) or ST (OR 1.58, 95%CI 0.67-3.73, p= 0.30). Conclusions: These data suggests that BP-DES are more efficacious when compared with PF-DES for the treatment of CAD. (c) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:865 / 870
页数:6
相关论文
共 50 条
  • [31] Polymer-free dual drug-eluting stents evaluated in a porcine model
    Zhang, Bin
    Zheng, Bo
    Wang, Xingang
    Shi, Qiuping
    Jia, Jia
    Huo, Yong
    Pan, Chunshui
    Han, Jingyan
    Chen, Ming
    [J]. BMC CARDIOVASCULAR DISORDERS, 2017, 17
  • [32] Polymer-free drug-eluting stents — a safe and effective option for ACS
    Yukinori Harada
    Adnan Kastrati
    [J]. Nature Reviews Cardiology, 2016, 13 : 447 - 448
  • [33] Polymer-free dual drug-eluting stents evaluated in a porcine model
    Bin Zhang
    Bo Zheng
    Xingang Wang
    Qiuping Shi
    Jia Jia
    Yong Huo
    Chunshui Pan
    Jingyan Han
    Ming Chen
    [J]. BMC Cardiovascular Disorders, 17
  • [34] PATENT WATCH Patent insight into polymer-free drug-eluting stents
    Demidov, Vadim
    Currie, Daniel
    Wen, Justin
    [J]. NATURE REVIEWS DRUG DISCOVERY, 2017, 16 (04) : 230 - U96
  • [35] Polymer-free drug-eluting stents - a safe and effective option for ACS
    Harada, Yukinori
    Kastrati, Adnan
    [J]. NATURE REVIEWS CARDIOLOGY, 2016, 13 (08) : 447 - 448
  • [36] Polymer drug-eluting stents: is the future biodegradable?
    Waksman, Ron
    Maluenda, Gabriel
    [J]. LANCET, 2011, 378 (9807): : 1900 - 1902
  • [37] Polymer-free versus permanent polymer drug-eluting stents: an updated meta-analysis of randomized trials
    Nogic, Jason
    Baey, Yi-Wei
    Nerlekar, Nitesh
    Cameron, James
    Nasis, Arthur
    Brown, Adam
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (18) : B317 - B318
  • [38] Comparison of the safety and efficacy of biodegradable polymer drug-eluting stents versus durable polymer drug-eluting stents: a meta-analysis
    Lv, Jianfeng
    Wu, Yazhou
    Zhang, Xingmei
    Jing, Tao
    Zhang, Li
    Tong, Shifei
    Song, Zhiyuan
    Wang, Mingli
    Wang, Gang
    Chi, Luxiang
    [J]. EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2015, 20
  • [39] Comparison of the safety and efficacy of biodegradable polymer drug-eluting stents versus durable polymer drug-eluting stents: a meta-analysis
    Jianfeng Lv
    Yazhou Wu
    Xingmei Zhang
    Tao Jing
    Li Zhang
    Shifei Tong
    Zhiyuan Song
    Mingli Wang
    Gang Wang
    Luxiang Chi
    [J]. European Journal of Medical Research, 20
  • [40] New Drug-Eluting Stents An Overview on Biodegradable and Polymer-Free Next-Generation Stent Systems
    Abizaid, Alexandre
    Costa, J. Ribamar, Jr.
    [J]. CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (04) : 384 - 393