Tribological properties, corrosion resistance and biocompatibility of magnetron sputtered titanium-amorphous carbon coatings

被引:49
|
作者
Dhandapani, Vishnu Shankar [1 ,2 ]
Subbiah, Ramesh [3 ,4 ]
Thangavel, Elangovan [1 ,2 ]
Arumugam, Madhankumar [5 ]
Park, Kwideok [3 ,4 ]
Gasem, Zuhair M. [5 ]
Veeraragavan, Veeravazhuthi [1 ]
Kim, Dae-Eun [2 ,6 ]
机构
[1] PSG Coll Arts & Sci, PG & Res Dept Phys, Coimbatore 641014, Tamil Nadu, India
[2] Yonsei Univ, Ctr Nanowear, Seoul 120749, South Korea
[3] Korea Inst Sci & Technol, Ctr Biomat, Seoul 136791, South Korea
[4] Korea Univ Sci & Technol UST, Dept Biomed Engn, Daejon 305333, South Korea
[5] King Fahd Univ Petr & Minerals, Ctr Res Excellence Corros, Dhahran 31261, Saudi Arabia
[6] Yonsei Univ, Dept Mech Engn, Seoul 120749, South Korea
基金
新加坡国家研究基金会;
关键词
Amorphous carbon; 316L SS; Tribological property; Preosteoblasts; Corrosion; DIAMOND-LIKE CARBON; MECHANICAL-PROPERTIES; DLC FILMS; SURFACE; 316L; MICROSTRUCTURE; BEHAVIOR; STEEL; TI; BIOMATERIALS;
D O I
10.1016/j.apsusc.2016.02.194
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Amorphous carbon incorporated with titanium (a-C:Ti) was coated on 316L stainless steel (SS) by magnetron sputtering technique to attain superior tribological properties, corrosion resistance and biocompatibility. The morphology, topography and functional groups of the nanostructured a-C:Ti coatings in various concentrations were analyzed using atomic force microscopy (AFM), Raman, X-Ray photoelectron spectroscopy (XPS) and transmission electron microscopy (TEM). Raman and XPS analyses confirmed the increase in sp(2) bonds with increasing titanium content in the a-C matrix. TEM analysis confirmed the composite nature of the coating and the presence of nanostructured TiC for Ti content of 2.33 at.%. This coating showed superior tribological properties compared to the other a-C:Ti coatings. Furthermore, electrochemical corrosion studies were performed against stimulated body fluid medium in which all the a-C:Ti coatings showed improved corrosion resistance than the pure a-C coating. Preosteoblasts proliferation and viability on the specimens were tested and the results showed that a-C:Ti coatings with relatively high Ti (3.77 at.%) content had better biocompatibility. Based on the results of this work, highly durable coatings with good biocompatibility could be achieved by incorporation of optimum amount of Ti in a-C coatings deposited on SS by magnetron sputtering technique. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:262 / 274
页数:13
相关论文
共 50 条
  • [21] Corrosion resistance and biocompatibility of titanium surface coated with amorphous tantalum pentoxide
    Sun, Ying-Sui
    Chang, Jean-Heng
    Huang, Her-Hsiung
    THIN SOLID FILMS, 2013, 528 : 130 - 135
  • [22] Influence of Nitride Coatings on Corrosion Resistance and the Biocompatibility of Titanium Alloy Products
    Sotova, Catherine
    Yanushevich, Oleg
    Krikheli, Natella
    Kramar, Olga
    Vereschaka, Alexey
    Shehtman, Semen
    Milovich, Filipp
    Zhylinski, Valery
    Seleznev, Anton
    Peretyagin, Pavel
    METALS, 2024, 14 (11)
  • [23] Tribological and Corrosion Properties of Nickel Coatings on Carbon Steel
    Vite-Torres, Jaime
    Vite-Torres, Manuel
    Aguilar-Osorio, Rita
    Eliseo Reyes-Astivia, Jesus
    FME TRANSACTIONS, 2015, 43 (03): : 206 - 210
  • [24] EFFECTS OF PLASMA PROPERTIES ON MAGNETRON SPUTTERED AMORPHOUS-CARBON FILMS
    RUSSAK, MA
    ROSSNAGEL, SM
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1986, 133 (08) : C310 - C310
  • [25] Structural and tribological properties of DC reactive magnetron sputtered titanium/titanium nitride (Ti/TiN) multilayered coatings (vol 205, pg 3485, 2011)
    Subramanian, B.
    Ananthakumar, R.
    Jayachandran, M.
    SURFACE & COATINGS TECHNOLOGY, 2023, 455
  • [26] Unbalanced magnetron sputtered carbon composite coatings
    Zeng, XT
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1999, 17 (04): : 1991 - 1995
  • [27] TRIBOLOGICAL PROPERTIES OF AMORPHOUS DIAMOND-LIKE CARBON COATINGS
    MAILLAT, M
    HINTERMANN, HE
    SURFACE & COATINGS TECHNOLOGY, 1994, 68 : 638 - 643
  • [28] MICROSTRUCTURAL AND MORPHOLOGICAL EFFECTS ON THE TRIBOLOGICAL PROPERTIES OF ELECTRON ENHANCED MAGNETRON-SPUTTERED HARD COATINGS
    SCHNEIDER, JM
    VOEVODIN, AA
    REBHOLZ, C
    MATTHEWS, A
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1995, 13 (04): : 2189 - 2193
  • [29] Biocompatibility of Titanium Oxynitride Coatings Deposited by Reactive Magnetron Sputtering
    Kim, I. I.
    Surovtseva, M. A.
    Poveshchenko, O., V
    Bondarenko, N. A.
    Chepeleva, E., V
    Zhuravleva, I. Yu
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 2022, 173 (06) : 779 - 782
  • [30] Biocompatibility of Titanium Oxynitride Coatings Deposited by Reactive Magnetron Sputtering
    I. I. Kim
    M. A. Surovtseva
    O. V. Poveshchenko
    N. A. Bondarenko
    E. V. Chepeleva
    I. Yu. Zhuravleva
    Bulletin of Experimental Biology and Medicine, 2022, 173 : 779 - 782