THE RADON TRANSFORM FOR TERAHERTZ COMPUTED TOMOGRAPHY INCORPORATING THE BEAM SHAPE

被引:0
|
作者
Lumbeeck, Lars-Paul [1 ]
Paramonov, Pavel [1 ]
Sijbers, Jan [1 ]
De Beenhouwer, Jan [1 ]
机构
[1] Univ Antwerp, Dept Phys, Imec VisionLab, Antwerp, Belgium
关键词
Computed tomography; Terahertz imaging; Radon transform; Beam shape;
D O I
暂无
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
In this paper, we study the influence of the beam shape of Terahertz (THz) radiation on the image formation in THz computed tomography and how to account for it in the reconstruction process. This is accomplished by first considering the beam shape in the forward projection using a modified Radon transform and then inverting this transform to construct new inversion techniques. Simulation experiments show that, compared to conventional back projection, directly incorporating the beam shape in the Radon transform can significantly improve image quality in terms of the mean squared error and the Structural Similarity Index.
引用
收藏
页码:3040 / 3044
页数:5
相关论文
共 50 条
  • [21] The Radon Transform, Inverse Problems, and tomography - Preface
    Olafsson, G
    Quinto, ET
    Radon Transform, Inverse Problems, and Tomography, 2006, 63 : VII - XI
  • [22] Beam Hardening Correction for Interior Tomography based on Exponential Formed Model and Radon Inversion Transform
    Chen, Siyu
    Zhang, Hanming
    Li, Lei
    Xi, Xiaoqi
    Han, Yu
    Yan, Bin
    OPTICAL MEASUREMENT TECHNOLOGY AND INSTRUMENTATION, 2016, 10155
  • [23] Radon transform and pattern functions in quantum tomography
    Wunsche, A
    JOURNAL OF MODERN OPTICS, 1997, 44 (11-12) : 2293 - 2331
  • [24] HDR TOMOGRAPHY VIA MODULO RADON TRANSFORM
    Beckmann, Matthias
    Krahmer, Felix
    Bhandari, Ayush
    2020 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2020, : 3025 - 3029
  • [25] Refraction losses in terahertz computed tomography
    Abraham, E.
    Younus, A.
    Aguerre, C.
    Desbarats, P.
    Mounaix, P.
    OPTICS COMMUNICATIONS, 2010, 283 (10) : 2050 - 2055
  • [26] Neutron Strain Tomography using the Radon Transform
    Kirkwood, Henry J.
    Zhang, Shu Yan
    Tremsin, Anton S.
    Korsunsky, Alexander M.
    Baimpas, Nikolaos
    Abbey, Brian
    MATERIALS TODAY-PROCEEDINGS, 2015, 2 : 414 - 423
  • [27] Elimination of Fresnel Reflection Boundary Effects and Beam Steering in Pulsed Terahertz Computed Tomography
    Suman Mukherjee
    John Federici
    Paulo Lopes
    Miguel Cabral
    Journal of Infrared, Millimeter, and Terahertz Waves, 2013, 34 : 539 - 555
  • [28] Radon transform on the cylinder and tomography of a particle on the circle
    Asorey, M.
    Facchi, P.
    Man'ko, V. I.
    Marmo, G.
    Pascazio, S.
    Sudarshan, E. G. C.
    PHYSICAL REVIEW A, 2007, 76 (01):
  • [29] Motion detection in cone-beam computed tomography incorporating a geometric calibration approach
    Pua, Rizza D.
    Yoo, Boyeol
    Kim, Chang Hwan
    Cho, Seungryong
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [30] Three-dimensional microscopic computed tomography based on generalized Radon transform for optical imaging systems
    Kikuchi, S
    Sonobe, K
    Ohyama, N
    OPTICS COMMUNICATIONS, 1996, 123 (4-6) : 725 - 733