MRI scanners and the stapes prosthesis

被引:11
|
作者
Fritsch, Michael H.
机构
[1] Department of Otolaryngology-Head and Neck Surgery, Indiana University, School of Medicine, Indianapolis, IN
[2] Department of Otolaryngology-Head and Neck Surgery, Indiana University, Medical Center, Indianapolis, IN 46202
关键词
magnetic; MRI scan; otosclerosis; prosthesis; stapes;
D O I
10.1097/MAO.0b013e318125652a
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: Physicians and patients alike have concerns regarding exposing in vivo implanted metal stapes prostheses to magnetic resonance imaging (MRI) scanners. As MRI scanners become more powerful, the possibility for stapes prosthesis displacement due to ferromagnetic forces increases. It is hypothesized that some metal stapes prostheses may be exposed to powerful MRI scanners without leading to potential adversities for patients. Study Design: Literature review, retrospective case review, and physician survey. Settings: Tertiary care, University Medical Center. Materials and Methods: A review of the medical literature, a retrospective case review, and a clinical survey were performed. Results: In the history of stapes prostheses, I adverse patient outcome was causally substantiated when a defective stapes prosthesis was exposed to an MRI field. Otherwise, a review of the literature on experiments investigating stapes prostheses and MRI fields revealed a lack of any adverse clinical reports. In addition, 2 physician's surveys revealed no other cases of symptoms or damage to the ears of patients with stapes prostheses that had been exposed to an MRI scanner. Conclusion: All patients with a metallic stapes prosthesis may be sent to the MRI scanner, with the exception of I specific defective prosthesis type. The exception is a 1987 accidental mismanufacture of several lots of McGee pistons with a magnetic alloy. Patients with these specifically identified lots of McGee pistons should go to a computed tomographic scanner or be reimplanted with another prosthesis if MRI scans are mandatory. It would be advisable for manufacturers to use nonferromagnetic metals such as titanium for production of future stapes prostheses.
引用
收藏
页码:733 / 738
页数:6
相关论文
共 50 条
  • [21] The Stapes Prosthesis Past, Present, and Future
    Sevy, Alexander
    Arriaga, Moises
    OTOLARYNGOLOGIC CLINICS OF NORTH AMERICA, 2018, 51 (02) : 393 - +
  • [22] STAPES-REPLACING PROSTHESIS (SRP)
    SADE, J
    YANIV, E
    GASSNER, S
    LEVY, M
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1983, 97 (08): : 677 - 684
  • [23] Hydrodynamics of a vibrating stapes prosthesis in stapedotomy
    Pozrikidis, C.
    ENGINEERING ANALYSIS WITH BOUNDARY ELEMENTS, 2007, 31 (01) : 1 - 9
  • [24] Safety and efficacy of the mAXIS stapes prosthesis
    Bevis, Nicholas
    Hueser, Marc A.
    Oestreicher, David
    Beutner, Dirk
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2024, 281 (12) : 6317 - 6323
  • [25] ANALOG MODEL FOR STAPES PROSTHESIS EVALUATION
    LONGO, SE
    BYERS, VW
    MEDICAL RESEARCH ENGINEERING, 1971, 10 (01) : 12 - &
  • [26] Modified stapes prosthesis to limit postoperative vertigo
    Wang, ZM
    Chi, FL
    Dai, CF
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2005, 132 (01) : 50 - 54
  • [27] Nitinol as memory metal for the coupling of stapes prosthesis
    Zahnert, T.
    HNO, 2007, 55 (03) : 158 - 162
  • [28] DIAMETER OF LONG PROCESS OF INCUS FOR STAPES PROSTHESIS
    Toth, Miklos
    OTOLOGY & NEUROTOLOGY, 2015, 36 (05) : 941 - 941
  • [29] Chamber stapes prosthesis with an improved fastening of the membrane
    Pudlik, Malgorzata
    Skarzynski, Henryk
    Kwacz, Monika
    II INTERNATIONAL CONFERENCE OF COMPUTATIONAL METHODS IN ENGINEERING SCIENCE (CMES'17), 2017, 15
  • [30] A prospective evaluation of the Essen titanium stapes prosthesis
    Dost, P
    Arweiler-Harbeck, D
    Jahnke, K
    CLINICAL OTOLARYNGOLOGY, 2005, 30 (01) : 21 - 24