Percutaneous closure of perimembranous ventricular septal defect using patent ductus arteriosus occluders

被引:15
|
作者
Hieu Lan Nguyen [1 ,2 ]
Quang Tan Phan [3 ,4 ]
Dung Duc Doan [2 ]
Linh Huynh Dinh [1 ]
Hieu Ba Tran [1 ]
Sharmin, Saima [4 ]
Thottian, Julian Johny [4 ,5 ]
Won, Hoyoun [4 ]
Lee, Wang Soo [4 ]
Shin, Seung Yong [4 ]
Truong Quang Nguyen [3 ]
Kim, Sang Wook [4 ]
机构
[1] Vietnam Natl Heart Inst, Intervent Ctr, Hanoi, Vietnam
[2] Hanoi Med Univ Hosp, Intervent Ctr, Hanoi, Vietnam
[3] Quang Nam Cent Gen Hosp, Intervent Ctr, Quang Nam, Vietnam
[4] Chung Ang Univ Hosp, Intervent Ctr, Seoul, South Korea
[5] Westft Grp Hosp, Intervent Ctr, Trichur, Kerala, India
来源
PLOS ONE | 2018年 / 13卷 / 11期
关键词
TRANSCATHETER DEVICE CLOSURE; MEMBRANOUS VSD OCCLUDER; COMPLETE HEART-BLOCK; ATRIOVENTRICULAR-BLOCK; SURGICAL CLOSURE; RISK-FACTORS; PRELIMINARY EXPERIENCE; FOLLOW-UP; REPAIR; OUTCOMES;
D O I
10.1371/journal.pone.0206535
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objectives To assess the safety and efficacy of percutaneous closure of perimembranous ventricular septal defect (PmVSD) using patent ductus arteriosus (PDA) occluders. Background Widespread use of conventional PmVSD closure devices has been limited by unacceptable high rate of complete heart block (CHB). The elegant design of PDA occluders is supposed to ease implantation, increase closure rate and minimize damage to adjacent structures. Thus, PDA occluders may reduce complications, especially the CHB, and offer a good alternative for PmVSD closure. Method From September 2008 to October 2015, patients who underwent attempted percutaneous VSD closure using PDA occluders were included in the study. Patient demographics, echocardiography measurements, procedure details and follow-up data until October 2017 were collected. Results In total, 321 patients with a mean age of 15.5 +/- 12.6 years and mean a weight of 33.3 +/- 20.5 kg were included in this study. The mean defect size was 4.8 +/- 2.1 mm. Implantation was successful in 307(95.6%) patients. The median follow-up time was 63 months (24 to 108 months). The closure rates were 89.5%, 91.5%, and 99.3% after the procedure 24 hours, 6 months and 2 years, respectively. Major complications occurred in 5 (1.7%) patients during the procedure and follow-up, including persistent CHB in 2 (0.7%) patients and device embolization in 3 (1.0%) patients. No death, disability, or other major complication was detected. Conclusion Percutaneous closure of PmVSD using PDA occluders is feasible, safe and efficacious in selected patients.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Percutaneous closure of perimembranous ventricular septal defects with Amplatzer occluders - a single centre experience
    Szkutnik, Malgorzata
    Kusa, Jacek
    Bialkowski, Jacek
    KARDIOLOGIA POLSKA, 2008, 66 (09) : 941 - 949
  • [22] Transcatheter closure of multi-hole perimembranous ventricular septal defect with aneurysm using two occluders
    Huang, Yi-Yuan
    Fang, Zhen-Fei
    Tang, Jian-Jun
    Tang, Liang
    Hu, Xin-Qun
    Zhou, Sheng-Hua
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2017, 13 (01): : 75 - 77
  • [23] Percutaneous Closure of Patent Ductus Arteriosus
    Barcroft, Megan
    McKee, Christopher
    Berman, Darren P.
    Taylor, Rachel A.
    Rivera, Brian K.
    Smith, Charles, V
    Slaughter, Jonathan L.
    El-Khuffash, Afif
    Backes, Carl H.
    CLINICS IN PERINATOLOGY, 2022, 49 (01) : 149 - +
  • [24] Transcatheter closure of perimembranous ventricular septal defects with ductal occluders
    Mahimarangaiah, Jayaranganath
    Subramanian, Anand
    Hemannasetty, Srinivasa Kikkeri
    Chandra, Subhash
    Karur, Satish
    Kodandaramasastry, Usha Mandikal
    Nanjappa, Manjunath Cholenahally
    CARDIOLOGY IN THE YOUNG, 2015, 25 (05) : 918 - 926
  • [25] Nit-Occlud Le VSD coil versus Duct Occluders for percutaneous perimembranous ventricular septal defect closure
    Hieu Lan Nguyen
    Quang Tan Phan
    Linh Huynh Dinh
    Tran, Hieu Ba
    Won, Hoyoun
    Thottian, Julian Johny
    Dung Doan Duc
    Truong Nguyen Quang
    Kim, Sang Wook
    CONGENITAL HEART DISEASE, 2018, 13 (04) : 584 - 593
  • [26] VENTRICULAR SEPTAL DEFECT WITH AORTIC INCOMPETENCE SIMULATING PATENT DUCTUS ARTERIOSUS
    CLAYPOOL, JG
    RUTH, W
    LIN, TK
    AMERICAN HEART JOURNAL, 1957, 54 (05) : 788 - 793
  • [27] VENTRICULAR SEPTAL DEFECT WITH AORTIC INCOMPETENCE SIMULATING PATENT DUCTUS ARTERIOSUS
    WINCHELL, P
    BASHOUR, F
    AMERICAN JOURNAL OF MEDICINE, 1956, 20 (03): : 361 - 365
  • [28] VENTRICULAR SEPTAL DEFECT WITH PATENT DUCTUS ARTERIOSUS - A CLINICAL AND HEMODYNAMIC STUDY
    SASAHARA, AA
    NADAS, AS
    RUDOLPH, AM
    WITTENBORG, MH
    GROSS, RE
    CIRCULATION, 1960, 22 (02) : 254 - 264
  • [29] Percutaneous closure of perimembranous ventricular septal defect associated with a ventricular septal aneurysm using the Amplatzer ductal occluder
    Tan, CA
    Levi, DS
    Moore, JW
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 66 (03) : 427 - 431
  • [30] Transcatheter Closure of Perimembranous Ventricular Septal Defect in Children: Safety and Efficiency with Symmetric and Asymmetric Occluders
    Yang, Rong
    Sheng, Yanhui
    Cao, Kejiang
    Kong, Xiangqing
    Xu, Di
    Yong, Yonghong
    Zhou, Lei
    Zhang, Hao
    Qian, Linmei
    Sun, Wei
    Gu, Zhengnan
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 77 (01) : 84 - 90