Percutaneous closure of perimembranous ventricular septal defect using patent ductus arteriosus occluders

被引:15
|
作者
Hieu Lan Nguyen [1 ,2 ]
Quang Tan Phan [3 ,4 ]
Dung Duc Doan [2 ]
Linh Huynh Dinh [1 ]
Hieu Ba Tran [1 ]
Sharmin, Saima [4 ]
Thottian, Julian Johny [4 ,5 ]
Won, Hoyoun [4 ]
Lee, Wang Soo [4 ]
Shin, Seung Yong [4 ]
Truong Quang Nguyen [3 ]
Kim, Sang Wook [4 ]
机构
[1] Vietnam Natl Heart Inst, Intervent Ctr, Hanoi, Vietnam
[2] Hanoi Med Univ Hosp, Intervent Ctr, Hanoi, Vietnam
[3] Quang Nam Cent Gen Hosp, Intervent Ctr, Quang Nam, Vietnam
[4] Chung Ang Univ Hosp, Intervent Ctr, Seoul, South Korea
[5] Westft Grp Hosp, Intervent Ctr, Trichur, Kerala, India
来源
PLOS ONE | 2018年 / 13卷 / 11期
关键词
TRANSCATHETER DEVICE CLOSURE; MEMBRANOUS VSD OCCLUDER; COMPLETE HEART-BLOCK; ATRIOVENTRICULAR-BLOCK; SURGICAL CLOSURE; RISK-FACTORS; PRELIMINARY EXPERIENCE; FOLLOW-UP; REPAIR; OUTCOMES;
D O I
10.1371/journal.pone.0206535
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objectives To assess the safety and efficacy of percutaneous closure of perimembranous ventricular septal defect (PmVSD) using patent ductus arteriosus (PDA) occluders. Background Widespread use of conventional PmVSD closure devices has been limited by unacceptable high rate of complete heart block (CHB). The elegant design of PDA occluders is supposed to ease implantation, increase closure rate and minimize damage to adjacent structures. Thus, PDA occluders may reduce complications, especially the CHB, and offer a good alternative for PmVSD closure. Method From September 2008 to October 2015, patients who underwent attempted percutaneous VSD closure using PDA occluders were included in the study. Patient demographics, echocardiography measurements, procedure details and follow-up data until October 2017 were collected. Results In total, 321 patients with a mean age of 15.5 +/- 12.6 years and mean a weight of 33.3 +/- 20.5 kg were included in this study. The mean defect size was 4.8 +/- 2.1 mm. Implantation was successful in 307(95.6%) patients. The median follow-up time was 63 months (24 to 108 months). The closure rates were 89.5%, 91.5%, and 99.3% after the procedure 24 hours, 6 months and 2 years, respectively. Major complications occurred in 5 (1.7%) patients during the procedure and follow-up, including persistent CHB in 2 (0.7%) patients and device embolization in 3 (1.0%) patients. No death, disability, or other major complication was detected. Conclusion Percutaneous closure of PmVSD using PDA occluders is feasible, safe and efficacious in selected patients.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Patent ductus arteriosus closure using an Amplatzer™ ventricular septal defect closure device
    Fernando, Rajeev
    Koranne, Ketan
    Loyalka, Pranav
    Kar, Biswajit
    Gregoric, Igor
    EXPERIMENTAL & CLINICAL CARDIOLOGY, 2013, 18 (01): : E50 - E54
  • [2] Percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder
    Xi, Er-Ping
    Zhu, Jian
    Zhu, Shui-Bo
    Yin, Gui-Lin
    Liu, Yong
    Dong, Yong-Qiang
    Zhang, Yu
    Xia, Feng
    CLINICS, 2012, 67 (11) : 1281 - 1283
  • [3] Simultaneous transcatheter therapy for perimembranous ventricular septal defect combined with patent ductus arteriosus
    Wang, Qiguang
    Zhu, Xianyang
    Duanzhen, Zhang
    Zhang, Po
    Chen, Huoyuan
    Han, Xiumin
    Sheng, Xiaotang
    Meng, Lili
    JOURNAL OF CARDIAC SURGERY, 2017, 32 (06) : 370 - 375
  • [4] Patent ductus arteriosus closure using an Amplatzer ventricular septal defect closure device in adulthood
    Hattach, Loua
    Afrikh, Kawtar
    Fellat, Nadia
    Fellat, Rokya
    COR ET VASA, 2020, 62 (01) : 72 - 74
  • [5] Transcatheter treatment of perimembranous ventricular septal defect, secundum atrial septal defect and patent ductus arteriosus in a child
    Butera, Gianfranco
    Piazza, Luciane
    Hijazi, Ziyad
    Chessa, Massimo
    Carminati, Mario
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2006, 7 (10) : 775 - 778
  • [6] Simultaneous transcatheter closure of atrial septal defect, ventricular septal defect, and patent ductus arteriosus
    Emral, Hicran Gul
    Gupta, Palak
    Fraisse, Alain
    CARDIOLOGY IN THE YOUNG, 2025,
  • [7] PATENT DUCTUS ARTERIOSUS WITH VENTRICULAR SEPTAL DEFECT
    HIGGINS, GL
    BRITISH HEART JOURNAL, 1958, 20 (03): : 421 - 423
  • [8] Transcatheter closure of ventricular septal defects with nitinol wire occluders of type patent ductus arteriosus
    Wierzyk, Arkadiusz
    Szkutnik, Malgorzata
    Fiszer, Roland
    Banaszak, Pawel
    Pawlak, Szymon
    Bialkowski, Jacek
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2014, 10 (01): : 21 - 25
  • [9] Infective aortic valve endocarditis in a cat with patent ductus arteriosus and perimembranous ventricular septal defect
    Brennan, C.
    Gunasekaran, T.
    Williams, K.
    Sanders, R. A.
    JOURNAL OF VETERINARY CARDIOLOGY, 2020, 31 : 30 - 35
  • [10] VENTRICULAR SEPTAL DEFECT SIMULATING PATENT DUCTUS ARTERIOSUS
    DANARAJ, TJ
    BRITISH HEART JOURNAL, 1956, 18 (02): : 279 - 282