Commissioning of a multi-purpose offline ion source at the TITAN experiment

被引:0
|
作者
Flowerdew, Jake A. D. [1 ]
Mukul, Ish [2 ]
Kwiatkowski, Anna A. [2 ,3 ]
Wieser, Michael E. [1 ,2 ]
Thompson, Robert, I [1 ,2 ]
Dilling, Jens [2 ,4 ]
机构
[1] Univ Calgary, Dept Phys & Astron, Calgary, AB, Canada
[2] TRIUMF, Vancouver, BC, Canada
[3] Univ Victoria, Dept Phys & Astron, Victoria, BC, Canada
[4] Univ British Columbia, Dept Phys & Astron, Vancouver, BC, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Plasma Ion Source; SIMION; Time-of-Flight; Mass Spectrometry; MASS MEASUREMENTS;
D O I
10.1016/j.nima.2021.165399
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The controlled focusing and transport of ion beams is of paramount importance in particle accelerators, high energy beamlines, and detector systems, as it determines the sensitivity and resolution of the instruments. Therefore, it is essential to model the beam dynamics before the commissioning of new instruments in order to optimise properties such as transmission and energy spread. In this paper, a commercial Plasma Ion Source (PIS), comprised of a heated filament and anode followed by its collimating optics, was modelled using Monte Carlo simulations run with the commercial software SIMION. The simulations were performed for the integration of the source within the existing ion transport optics of TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). Optimising the voltage configurations using these simulations proved successful in the commissioning of the PIS operated in surface ionisation mode at the TITAN experiment. A Time-of-Flight (TOF) mass spectroscopy method was developed which allowed for the identification of species ionised by the source. The integration of a flexible ion source into the TITAN experiment will open up new opportunities to perform Isotopic Ratios Mass Spectrometry (IRMS) measurements at TITAN.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] A MULTI-PURPOSE CONSENT FORM
    ADDISON, PH
    LANCET, 1969, 2 (7616): : 377 - &
  • [42] The management of a multi-purpose reservoir
    Turgeon, A.
    MANAGEMENT OF NATURAL RESOURCES, SUSTAINABLE DEVELOPMENT AND ECOLOGICAL HAZARDS, 2007, 99 : 565 - 575
  • [43] TREVIRA: multi-purpose fabric
    Bobrowski, S
    TEKSTIL, 2003, 52 (06): : 285 - 286
  • [44] 'GOLF', A MULTI-PURPOSE CHAIR
    不详
    DOMUS, 1975, (553): : 36 - 36
  • [45] Multi-purpose image database
    Quirke, P
    Banks, RI
    Branch, T
    Dalzell, S
    JOURNAL OF PATHOLOGY, 1997, 181 : A20 - A20
  • [46] Development of Multi-Purpose Wheelchair
    Daud, Mohd Elias
    Hamid, Zulkarnain
    Desa, Asri Md.
    2015 Innovation & Commercialization of Medical Electronic Technology Conference (ICMET), 2015, : 22 - 25
  • [47] A SIMPLE MULTI-PURPOSE TITRIMETER
    JENNISON, W
    CLARK, ML
    ANALYST, 1966, 91 (1086) : 598 - &
  • [48] MULTI-PURPOSE EMBEDDED SYSTEM
    Maitra, Subhashis
    ICMEE 2009: PROCEEDINGS OF THE 2009 INTERNATIONAL CONFERENCE ON MECHANICAL AND ELECTRONICS ENGINEERING, 2010, : 21 - 26
  • [49] A MULTI-PURPOSE PLANKTON SAMPLER
    BEVERTON, RJ
    TUNGATE, DS
    JOURNAL DU CONSEIL, 1967, 31 (02): : 145 - &
  • [50] MULTI-PURPOSE LOCK AT NUSSDORF
    GRZYWIEN.A
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS, 1967, 36 (APR): : 805 - &