Use of a new intra-ocular spectral domain optical coherence tomography in vitreoretinal surgery

被引:17
|
作者
Mura, Marco [1 ,7 ,8 ]
Iannetta, Danilo [1 ,2 ]
Nasini, Francesco [1 ,3 ]
Barca, Francesco [1 ,9 ]
Peiretti, Enrico [1 ,4 ]
Engelbrecht, Leonore [1 ]
de Smet, Marc D. [5 ]
Verbraak, Frank [1 ,6 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Ophthalmol, NL-1105 AZ Amsterdam, Netherlands
[2] Univ Roma Tor Vergata, Dept Ophthalmol, Rome, Italy
[3] Univ Pisa, Dept Surg, Med Mol & Crit Area Pathol, I-56100 Pisa, Italy
[4] Univ Cagliari, Dept Surg Sci, Cagliari, Italy
[5] MIOS Sa, Lausanne, Switzerland
[6] Univ Amsterdam, Acad Med Ctr, Ctr Laser, NL-1105 AZ Amsterdam, Netherlands
[7] Johns Hopkins Univ, Wilmer Eye Inst, Baltimore, TX USA
[8] King Khalid Eye Specialist Hosp, Al Urubah Branch Rd, Riyadh 12329, Saudi Arabia
[9] Univ Florence, Dept Ophthalmol, AOUC, Florence, Italy
关键词
image-guided surgery; intraoperative optical coherence tomography; optical coherence tomography; retinal detachment; retinal surgery; vitrectomy vitreoretinal disease; INTRAOPERATIVE OCT; DYNAMICS; RETINA;
D O I
10.1111/aos.12961
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo describe the use of a novel intra-ocular side-scanning probe enabling the acquisition of spectral-domain optical coherence tomography (SD-OCT) images during surgery in a series of patients with complex forms of retinal detachment. MethodsA 23-gauge, side-scanning SD-OCT probe (C7 System; LightLab Imaging, Inc/St Jude Medical, St. Paul, MN, USA) in a 20-gauge catheter, was used to acquire the intra-operative OCT images in seven patients with vitreoretinal diseases. Twenty-five gauge pars plana vitrectomy (PPV) was performed in every patient in a standard fashion. After enlarging the temporal sclerotomy to a 20-gauge port, all the patients were scanned with intra-ocular side-scanning SD-OCT, during different steps of the surgery based on surgeon needs. Scans were recorded real time and directly evaluated on a screen during surgery. Optical coherence tomography (OCT) scans were judged beneficial when they would recognize structures otherwise not seen on biomicroscopy. ResultsThe intra-ocular SD-OCT has been helpful in acquiring extra information during vitreoretinal surgery such as the detection of the presence of otherwise invisible membranes (epiretinal membrane, subretinal membrane), the location of small tears and the identification of the retinal plane under suboptimal conditions for visualization. ConclusionThe use of an intra-ocular SD-OCT can expand upon visual cues during surgery, helping in the decision-making process and allowing additional deliberate surgical manoeuvres aimed at improving surgical outcomes.
引用
收藏
页码:246 / 252
页数:7
相关论文
共 50 条
  • [41] NORMOCAPNIC ANESTHESIA FOR INTRA-OCULAR SURGERY
    ADAMS, AP
    FREEDMAN, A
    HENVILLE, JD
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1979, 63 (03) : 204 - 210
  • [42] A NEW ANALGESIC DRUG, PHENAZOCINE, USED IN INTRA-OCULAR SURGERY
    THOMAS, KB
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1962, : 110 - &
  • [43] Optical coherence tomography use in evaluation of the vitreoretinal interface: A review
    Mirza, Rukhsana G.
    Johnson, Mark W.
    Jampol, Lee M.
    SURVEY OF OPHTHALMOLOGY, 2007, 52 (04) : 397 - 421
  • [44] Influence of cataract surgery on repeatability and measurements of spectral domain optical coherence tomography
    Bambo, Maria P.
    Garcia-Martin, Elena
    Otin, Sofia
    Sancho, Eva
    Fuertes, Isabel
    Herrero, Raquel
    Satue, Maria
    Pablo, Luis
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2014, 98 (01) : 52 - 58
  • [45] Spectral-Domain Optical Coherence Tomography for Monitoring Epiretinal Membrane Surgery
    Falkner-Radler, Christiane I.
    Glittenberg, Carl
    Hagen, Stefan
    Benesch, Thomas
    Binder, Susanne
    OPHTHALMOLOGY, 2010, 117 (04) : 798 - 805
  • [46] A new spectral calibration method for Fourier domain optical coherence tomography
    Ding, Chao
    Bu, Peng
    Wang, Xiangzhao
    Sasaki, Osami
    OPTIK, 2010, 121 (11): : 965 - 970
  • [47] Intraoperative Spectral-Domain Optical Coherence Tomography for Macular Pucker Surgery
    Baranano, D. E.
    Fortun, J. A.
    Ray, R.
    Charkoudian, L.
    Bergstrom, C.
    Cribbs, B.
    Schwent, B.
    Hubbard, G., III
    Srivastava, S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [48] Preoperative spectral-domain optical coherence tomography in cataract surgery Reply
    Abdelmassih, Youssef
    El-Khoury, Sylvain
    Georges, Sophie
    Guindolet, Damien
    Gabison, Eric
    Cochereau, Isabelle
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (10): : 1296 - 1297
  • [49] Vitreoretinal morphology in active ocular toxoplasmosis:: a prospective study by optical coherence tomography
    Orefice, Juliana L.
    Costa, Rogerio A.
    Orefice, Fernando
    Campos, Wesley
    da Costa-Lima, Decio, Jr.
    Scott, Ingrid U.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (06) : 773 - 780
  • [50] A NEW ANALGESIC DRUG, PHENAZOCINE, USED IN INTRA-OCULAR SURGERY
    THOMAS, KB
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1963, : 110 - &