Use of a new intra-ocular spectral domain optical coherence tomography in vitreoretinal surgery

被引:17
|
作者
Mura, Marco [1 ,7 ,8 ]
Iannetta, Danilo [1 ,2 ]
Nasini, Francesco [1 ,3 ]
Barca, Francesco [1 ,9 ]
Peiretti, Enrico [1 ,4 ]
Engelbrecht, Leonore [1 ]
de Smet, Marc D. [5 ]
Verbraak, Frank [1 ,6 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Ophthalmol, NL-1105 AZ Amsterdam, Netherlands
[2] Univ Roma Tor Vergata, Dept Ophthalmol, Rome, Italy
[3] Univ Pisa, Dept Surg, Med Mol & Crit Area Pathol, I-56100 Pisa, Italy
[4] Univ Cagliari, Dept Surg Sci, Cagliari, Italy
[5] MIOS Sa, Lausanne, Switzerland
[6] Univ Amsterdam, Acad Med Ctr, Ctr Laser, NL-1105 AZ Amsterdam, Netherlands
[7] Johns Hopkins Univ, Wilmer Eye Inst, Baltimore, TX USA
[8] King Khalid Eye Specialist Hosp, Al Urubah Branch Rd, Riyadh 12329, Saudi Arabia
[9] Univ Florence, Dept Ophthalmol, AOUC, Florence, Italy
关键词
image-guided surgery; intraoperative optical coherence tomography; optical coherence tomography; retinal detachment; retinal surgery; vitrectomy vitreoretinal disease; INTRAOPERATIVE OCT; DYNAMICS; RETINA;
D O I
10.1111/aos.12961
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo describe the use of a novel intra-ocular side-scanning probe enabling the acquisition of spectral-domain optical coherence tomography (SD-OCT) images during surgery in a series of patients with complex forms of retinal detachment. MethodsA 23-gauge, side-scanning SD-OCT probe (C7 System; LightLab Imaging, Inc/St Jude Medical, St. Paul, MN, USA) in a 20-gauge catheter, was used to acquire the intra-operative OCT images in seven patients with vitreoretinal diseases. Twenty-five gauge pars plana vitrectomy (PPV) was performed in every patient in a standard fashion. After enlarging the temporal sclerotomy to a 20-gauge port, all the patients were scanned with intra-ocular side-scanning SD-OCT, during different steps of the surgery based on surgeon needs. Scans were recorded real time and directly evaluated on a screen during surgery. Optical coherence tomography (OCT) scans were judged beneficial when they would recognize structures otherwise not seen on biomicroscopy. ResultsThe intra-ocular SD-OCT has been helpful in acquiring extra information during vitreoretinal surgery such as the detection of the presence of otherwise invisible membranes (epiretinal membrane, subretinal membrane), the location of small tears and the identification of the retinal plane under suboptimal conditions for visualization. ConclusionThe use of an intra-ocular SD-OCT can expand upon visual cues during surgery, helping in the decision-making process and allowing additional deliberate surgical manoeuvres aimed at improving surgical outcomes.
引用
收藏
页码:246 / 252
页数:7
相关论文
共 50 条
  • [1] Intraoperative spectral domain optical coherence tomography for vitreoretinal surgery
    Tao, Yuankai K.
    Ehlers, Justis P.
    Toth, Cynthia A.
    Izatt, Joseph A.
    OPTICS LETTERS, 2010, 35 (20) : 3315 - 3317
  • [2] Real-time intraoperative spectral domain optical coherence tomography for vitreoretinal surgery
    Tao, Yuankai K.
    Toth, Cynthia A.
    Izatt, Joseph A.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIV, 2010, 7554
  • [3] The use of intraoperative spectral domain optic coherence tomography in vitreoretinal surgery: The evaluation of efficacy
    Lytvynchuk, L.
    Glittenberg, C.
    Binder, S.
    ACTA OPHTHALMOLOGICA, 2015, 93
  • [4] The use of intraoperative spectral domain optic coherence tomography in vitreoretinal surgery: The evaluation of efficacy
    Lytvynchuk, L.
    Glittenberg, C.
    Binder, S.
    ACTA OPHTHALMOLOGICA, 2015, 93
  • [5] Spectral-domain optical coherence tomography biomarkers in vitreoretinal lymphoma
    Guan, Wenxue
    Xiao, Yuanyuan
    Zhao, Huiying
    Hu, Feng
    Chen, Chunli
    Peng, Xiaoyan
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 51 (02): : 144 - 153
  • [6] Use of Handheld Intraoperative Spectral-Domain Optical Coherence Tomography in a Variety of Vitreoretinal Diseases
    Branchini, Lauren A.
    Gurley, Kiersten
    Duker, Jay S.
    Reichel, Elias
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2016, 47 (01): : 49 - 54
  • [7] Prevalence of alterations in the vitreoretinal interface detected by spectral domain optical coherence tomography
    Jacob, Julie
    Stalmans, Peter
    OPHTHALMOLOGICA, 2017, 238 : 9 - 15
  • [8] SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY FEATURES OF VITREORETINAL LYMPHOMA IN 55 EYES
    Yang, Xiaolu
    Dalvin, Lauren A.
    Mazloumi, Mehdi
    Ferenczy, Sandor
    Lim, Li-Anne S.
    Ancona-Lezama, David
    Shields, Jerry A.
    Mashayekhi, Arman
    Shields, Carol L.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2021, 41 (02): : 249 - 258
  • [9] Spectral Domain Optical Coherence Tomography in the Diagnosis and Management of Vitreoretinal Interface Pathologies
    Barak, Yoreh
    Ihnen, Mark A.
    Schaal, Shlomit
    JOURNAL OF OPHTHALMOLOGY, 2012, 2012
  • [10] Intraoperative Optical Coherence Tomography in Vitreoretinal Surgery
    Ung, Cindy
    Miller, John B.
    SEMINARS IN OPHTHALMOLOGY, 2019, 34 (04) : 312 - 316