Determination of selected water-soluble vitamins (thiamine, riboflavin, nicotinamide and pyridoxine) from a food matrix using hydrophilic interaction liquid chromatography coupled with mass spectroscopy

被引:19
|
作者
Porter, Kate [1 ]
Lodge, John K. [1 ]
机构
[1] Northumbria Univ, Fac Hlth & Life Sci, Dept Appl Sci, Ellison Bldg, Newcastle Upon Tyne NE1 8ST, Tyne & Wear, England
关键词
Water-soluble vitamins; LC-MS; HILIC; Analysis; Food matrix; DIETARY-SUPPLEMENTS; HILIC SEPARATION; ARRAY; SPECTROMETRY; EXTRACTION; QUANTIFICATION; HYDROCHLORIDE; PYRIDOXAMINE; STABILITY; PRODUCTS;
D O I
10.1016/j.jchromb.2021.122541
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Water-soluble vitamins are essential dietary components with a multitude of important functions that require quantification from food sources to characterise the nutritional status of food. In this study, we have developed a hydrophilic interaction chromatography (HILIC) based method coupled to single-quadrupole mass spectrometry (MS) for the analysis of selected water-soluble vitamins. Due to their involvement in energy release from macronutrients, the quantification of thiamine (B1), riboflavin (B2), nicotinamide (B3) and pyridoxine (B6) offers significant value in food analysis. A commercially available vegetable soup was selected as the food matrix for this study and utilised to develop an efficient extraction procedure for the vitamins of interest. Vitamins were extracted using meta-phosphoric acid coupled with a reducing agent, DL-dithiothreitol (DTT) to produce the parent compound. The extracted vitamins were then analysed using an LC-MS system with electrospray ? atmospheric pressure ionization (ES-API) source, operated in positive single ion monitoring (SIM) mode. The MS provided good linearity within the investigated range from 5 to 400 ng/mL with coefficient of determination (r2) ranging from 0.98 to 0.99. Retention times (0.65?9.04 min) were reproducible and no coelution between vitamins was observed. Limit of detection (LOD) varied from 2.4 to 9.0 ng/mL and limit of quantification (LOQ) was from 8 to 30 ng/mL, comparable to previously published studies. The extraction method provided good intra-day (%CV 1.56?6.56) and inter-day precision (%CV 8.07?10.97). Standard injections were used as part of quality control measures and provided excellent reproducibility (%CV 0.9?3.4). The overall runtime of this method was 19 min, including column reconditioning. Using this method, the quantity of thiamine (67 ? 7 ng/g), riboflavin (423 ? 39 ng/g), nicotinamide (856 ? 77 ng/g) and pyridoxine (133 ? 11 ng/g) was determined from a complex food matrix. In conclusion, we have developed a rapid and reliable, HILIC-single quad MS method utilising SIM for the lowlevel quantification of four B vitamins in a vegetable soup matrix in under 20 min. This method has shown excellent linearity, intra- and inter-day reproducibility and is directly applicable to other plant-based food matrices.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Direct determination of underivatized amino acids from Ginkgo biloba leaves by using hydrophilic interaction ultra high performance liquid chromatography coupled with triple quadrupole mass spectrometry
    Yao, Xin
    Zhou, Guisheng
    Tang, Yuping
    Pang, Hanqing
    Qian, Yefei
    Guo, Sheng
    Mo, Xuan
    Zhu, Shaoqing
    Su, Shulan
    Qian, Dawei
    Jin, Chun
    Qin, Yong
    Duan, Jin-ao
    JOURNAL OF SEPARATION SCIENCE, 2013, 36 (17) : 2878 - 2887
  • [42] Determination of 13 synthetic food colorants in water-soluble foods by reversed-phase high-performance liquid chromatography coupled with diode-array detector
    Minioti, Katerina S.
    Sakellariou, Christina F.
    Thomaidis, Nikolaos S.
    ANALYTICA CHIMICA ACTA, 2007, 583 (01) : 103 - 110
  • [43] Automated determination of selected water-soluble vitamins in tablets using a bench-top robotic system coupled to reversed-phase (RP-18) HPLC with UV detection
    Höller, U
    Brodhag, C
    Knöbel, A
    Hofmann, P
    Spitzer, V
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 31 (01) : 151 - 158
  • [44] Determination of 11 Water-Soluble Organic Acids in Plants by Online Solid-Phase Extraction Coupled with High Performance Liquid Chromatography-High Resolution Mass Spectrometry
    Zhan N.
    Sun Q.
    Hao R.
    Guo F.
    Shipin Kexue/Food Science, 2023, 44 (04): : 256 - 264
  • [45] Preparative separation of polyphenols from water-soluble fraction of Chinese propolis using macroporous absorptive resin coupled with preparative high performance liquid chromatography
    Li, Aifeng
    Xuan, Hongzhuan
    Sun, Ailing
    Liu, Renmin
    Cui, Jichun
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1012 : 42 - 49
  • [46] Determination of diquat in water samples by hydrophilic interaction chromatography/electrospray ionization/mass spectrometry coupled with solid-phase extraction using a stable isotope labeled compound
    Makihata, Nobuko
    Yamasaki, Tomio
    Eiho, Jirou
    BUNSEKI KAGAKU, 2007, 56 (07) : 579 - 585
  • [47] Simultaneous quantification of fat-soluble vitamins A, 25-hydroxylvitamin D and vitamin E in plasma from children using liquid chromatography coupled to Orbitrap mass spectrometry
    Liu, Hao
    Wang, Dong-juan
    Wan, Ke-xing
    Zhang, Juan
    Yuan, Zhao-jian
    Yu, Chao-wen
    Yang, Jing
    Zou, Lin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1177
  • [48] CHARACTERIZATION AND MOLECULAR-WEIGHT DETERMINATION OF WATER-SOLUBLE POLYETHYLENE-GLYCOL OLIGOMERS USING OPEN-TUBING LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    LAI, ST
    JOURNAL OF CHROMATOGRAPHY, 1986, 363 (02): : 444 - 447
  • [49] Cost-Effective Simultaneous Determination of τ- and π-Methylhistidine in Dairy Bovine Plasma from Large Cohort Studies Using Hydrophilic Interaction Ultra-High Performance Liquid Chromatography Coupled to Tandem Mass Spectrometry
    Sampsonidis, Ioannis
    Marinaki, Maria
    Pesiridou, Anastasia
    Gika, Helen
    Theodoridis, Georgios
    Siachos, Nektarios
    Arsenos, Georgios
    Kalogiannis, Stavros
    SEPARATIONS, 2023, 10 (02)
  • [50] Determination of 27 bovine plasma amino acids and metabolites using zwitterionic-hydrophilic interaction liquid chromatography coupled with isotope dilution electrospray ionization triple quadrupole liquid chromatography-mass spectrometry and the effect of deproteinization timing
    Ortega, A. F.
    Van Amburgh, M. E.
    JDS COMMUNICATIONS, 2024, 5 (02): : 118 - 123