Simulator testing of total knee replacements

被引:0
|
作者
Blunn, GW [1 ]
Bell, CJ [1 ]
Walker, PS [1 ]
Chatterjee, S [1 ]
Perry, J [1 ]
Campbell, P [1 ]
Haider, H [1 ]
Paul, JP [1 ]
机构
[1] UCL, Inst Orthopaed, Ctr Biomed Engn, London, England
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In order to determine the effect of improvements in design and materials on wear of total knee replacement, a valid test method is required. This test method should reproduce the wear patterns seen on retrieved knee replacements. We have tested various designs of implants using a force-control knee simulator and analysed the wear on these implants. The tests were conducted in 50 per cent bovine serum for up to ten million cycles. On condylar replacements, wear was associated with scratching and burnishing. Wear rates between different designs could be discriminated. Delamination wear occurred only in those samples which had been artificially aged. Tests showed that wear on a meniscal knee design equalled that, or was greater than that, observed on a condylar design. On meniscal designs wear was associated mainly with the meniscal bearing surface.
引用
收藏
页码:113 / 125
页数:13
相关论文
共 50 条
  • [21] THE MANAGEMENT OF INFECTED TOTAL KNEE REPLACEMENTS
    FREEMAN, MAR
    SUDLOW, RA
    CASEWELL, MW
    RADCLIFF, SS
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (05): : 764 - 768
  • [22] Arthroscopy of symptomatic total knee replacements
    Bae, DK
    Lee, HK
    Cho, JH
    ARTHROSCOPY, 1995, 11 (06): : 664 - 671
  • [23] Fractures above total knee replacements
    Mannan, K.
    MINERVA ORTOPEDICA E TRAUMATOLOGICA, 2009, 60 (06) : 491 - 496
  • [24] THE TREATMENT OF INFECTED TOTAL KNEE REPLACEMENTS
    SUDLOW, RA
    RATCLIFFE, SS
    FREEMAN, MAR
    CASEWELL, MW
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (01): : 144 - 144
  • [25] Disparities in total knee replacements: A review
    Kane, Robert L.
    Wilt, Timothy
    Suarez-Almazor, Maria E.
    Fu, Steven S.
    ARTHRITIS & RHEUMATISM-ARTHRITIS CARE & RESEARCH, 2007, 57 (04): : 562 - 567
  • [26] TOTAL KNEE REPLACEMENTS WITH GEOMETRIC PROSTHESIS
    EVARTS, CM
    GOLDNER, JL
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1974, (102) : 280 - 280
  • [27] The use of knee splints after total knee replacements
    Zenios, M
    Wykes, P
    Johnson, DS
    Clayson, AD
    Kay, P
    KNEE, 2002, 9 (03): : 225 - 228
  • [28] REVISION OF FAILED TOTAL KNEE REPLACEMENTS WITH THE STANMORE HINGED KNEE
    KARPINSKI, MR
    GRIMER, RJ
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (03): : 489 - 489
  • [29] A knee simulating machine for performance evaluation of total knee replacements
    Walker, PS
    Blunn, GW
    Broome, DR
    Perry, J
    Watkins, A
    Sathasivam, S
    Dewar, ME
    Paul, JP
    JOURNAL OF BIOMECHANICS, 1997, 30 (01) : 83 - 89
  • [30] Design and construction of a simulator for testing finger joint replacements
    Schwarz, MLR
    Bouman, HW
    Bayer, M
    Feinle, P
    BIOMEDIZINISCHE TECHNIK, 2001, 46 (06): : 176 - 180