Diagnostic Performance of Flat-Panel CT Arthrography for Cartilage Defect Detection in the Ankle Joint: Comparison With MDCT Arthrography With Gross Anatomy as the Reference Standard

被引:7
|
作者
Chemouni, David [1 ]
Champsaur, Pierre [1 ,2 ]
Guenoun, Daphne [1 ,2 ]
Desrousseaux, Julie [3 ]
Pauly, Vanessa [4 ]
Le Corroller, Thomas [1 ,2 ]
机构
[1] Hop St Marguerite, APHM, Dept Radiol, F-13009 Marseille, France
[2] Aix Marseille Univ, CNRS, ISM UMR 7287, Marseille, France
[3] Hop La Timone, APHM, Dept Radiotherapy, Marseille, France
[4] Hop St Marguerite, APHM, DIM, F-13009 Marseille, France
关键词
anatomy; ankle; arthrography; CT; flat-panel; MRI; MULTIDETECTOR-COMPUTED-TOMOGRAPHY; MR-ARTHROGRAPHY; ARTICULAR-CARTILAGE; VOLUME CT; FUNDAMENTAL PRINCIPLES; CADAVERS; KNEE; THICKNESS; LESIONS;
D O I
10.2214/AJR.13.12163
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study is to compare the diagnostic performance and radiation exposure of flat-panel CT arthrography for cartilage defect detection in the ankle joint to standard MDCT arthrography, using gross anatomy and thermoluminescent dosimetry as reference standards. MATERIALS AND METHODS. Ten cadaveric ankle specimens were obtained from individuals who had willed their bodies to science. Five milliliters of a mixture of diluted ioxaglate and saline were injected. Specimens were examined consecutively with the use of flat-panel CT and MDCT. Radiation doses of flat-panel CT and MDCT were recorded using thermoluminescent dosimeters. Flat-panel CT and MDCT arthrography examinations were blinded and randomly evaluated by two musculoskeletal radiologists in consensus. In each ankle specimen, eight cartilage areas were assessed separately: medial talar surface, medial talar trochlea, lateral talar trochlea, lateral talar surface, tibial malleolus, medial tibial plafond, lateral tibial plafond, and fibular malleolus. Findings at flat-panel CT and MDCT arthrography were compared with macroscopic assessments in 80 cartilage areas. RESULTS. For the detection of cartilage lesions, flat-panel CT showed a sensitivity of 80%, specificity of 98%, and accuracy of 94%, and MDCT arthrography showed a sensitivity of 55%, specificity of 98%, and accuracy of 88%. Flat-panel CT and MDCT arthrography showed almost perfect (kappa = 0.83) and substantial (kappa = 0.65) agreement, respectively, with anatomic examination. Radiation dose was significantly lower for flat-panel CT (mean, 2.1 mGy; range, 1.1-3.0 mGy) than for MDCT (mean, 47.2 mGy; range, 39.3-53.8 mGy) (p < 0.01). CONCLUSION. Flat-panel CT arthrography is accurate for detecting cartilage defects in the ankle joint and is an alternative to MDCT arthrography that may have better diagnostic performance and may permit the use of a lower radiation dose.
引用
收藏
页码:1069 / 1074
页数:6
相关论文
共 19 条
  • [11] What Is the Diagnostic Accuracy of Flat-panel Cone-beam CT Arthrography for Diagnosis of Scapholunate Ligament Tears?
    Dornberger, Jenny E.
    Rademacher, Grit
    Stengel, Dirk
    Hoenning, Alexander
    Schueler, Gabriele
    Eisenschenk, Andreas
    Mutze, Sven
    Goelz, Leonie
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2021, 479 (01) : 151 - 160
  • [12] Cartilage lesions of the glenohumeral joint: diagnostic effectiveness of multidetector spiral CT arthrography and comparison with arthroscopy
    Frédéric E. Lecouvet
    Benjamin Dorzée
    Jean E. Dubuc
    Bruno C. Vande Berg
    Jacques Jamart
    Jacques Malghem
    European Radiology, 2007, 17 : 1763 - 1771
  • [13] Cartilage lesions of the glenohumeral joint: diagnostic effectiveness of multidetector spiral CT arthrography and comparison with arthroscopy
    Lecouvet, Frederic E.
    Dorzee, Benjamin
    Dubuc, Jean E.
    Vande Berg, Bruno C.
    Jamart, Jacques
    Malghem, Jacques
    EUROPEAN RADIOLOGY, 2007, 17 (07) : 1763 - 1771
  • [14] Comparison of MR-arthrography and CT-arthrography in hyaline cartilage-thickness measurement in radiographically normal cadaver hips with anatomy as gold standard
    Wyler, A.
    Bousson, V.
    Bergot, C.
    Polivka, M.
    Leveque, E.
    Vicaut, E.
    Laredo, Jean-Denis
    OSTEOARTHRITIS AND CARTILAGE, 2009, 17 (01) : 19 - 25
  • [15] CORR Insights®: What Is the Diagnostic Accuracy of Flat-panel Cone-beam CT Arthrography for Diagnosis of Scapholunate Ligament Tears?
    Degreef, Ilse
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2021, 479 (01) : 161 - 162
  • [16] Diagnostic performance of CT-arthrography and 1.5T MR-arthrography for the assessment of glenohumeral joint cartilage: a comparative study with arthroscopic correlation
    Patrick Omoumi
    Alexandra Rubini
    Jean-Emile Dubuc
    Bruno C. Vande Berg
    Frédéric E. Lecouvet
    European Radiology, 2015, 25 : 961 - 969
  • [17] Diagnostic performance of CT-arthrography and 1.5T MR-arthrography for the assessment of glenohumeral joint cartilage: a comparative study with arthroscopic correlation
    Omoumi, Patrick
    Rubini, Alexandra
    Dubuc, Jean-Emile
    Vande Berg, Bruno C.
    Lecouvet, Frederic E.
    EUROPEAN RADIOLOGY, 2015, 25 (04) : 961 - 969
  • [18] Diagnostic performance of shoulder magnetic resonance arthrography for labral tears having surgery as reference: comparison of high-resolution isotropic 3D sequence (THRIVE) with standard protocol
    Lee, Sun Hwa
    Yun, Seong Jong
    Yoon, Youngno
    RADIOLOGIA MEDICA, 2018, 123 (08): : 620 - 630
  • [19] Diagnostic performance of shoulder magnetic resonance arthrography for labral tears having surgery as reference: comparison of high-resolution isotropic 3D sequence (THRIVE) with standard protocol
    Sun Hwa Lee
    Seong Jong Yun
    Youngno Yoon
    La radiologia medica, 2018, 123 : 620 - 630