Fitness and retentive force of cobalt-chromium alloy clasps fabricated with repeated laser sintering and milling

被引:44
|
作者
Torii, Mana [1 ]
Nakata, Toyoki [1 ]
Takahashi, Kazuya [1 ]
Kawamura, Noboru [2 ]
Shimpo, Hidemasa [1 ]
Ohkubo, Chikahiro [1 ]
机构
[1] Tsurumi Univ, Sch Dent Med, Dept Removable Prosthodont, Yokohama, Kanagawa, Japan
[2] Tsurumi Univ Dent Hosp, Dept Tech Training Inst, Yokohama, Kanagawa, Japan
关键词
CAD/CAM; Clasp; Relief; Retentive force; Heat treatment; COMPUTER-AIDED-DESIGN; RAPID PROTOTYPING TECHNIQUES; PARTIAL DENTURE FRAMEWORKS; CO-CR; MECHANICAL-PROPERTIES; DEFLECTION FATIGUE; MARGINAL ACCURACY; CAST CLASPS; TITANIUM; FIT;
D O I
10.1016/j.jpor.2018.01.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: With computer-aided design and computer-aided manufacturing (CAD/CAM), the study was conducted to create a removable partial denture (RPD) framework using repeated laser sintering rather than milling and casting techniques. This study experimentally evaluated the CAM clasp and compared it to a conventional cast clasp. Methods: After the tooth die was scanned, an Akers clasp was designed using CAD with and without 50 mm of digital relief on the occlusal surface of the tooth die. Cobalt-chromium (Co-Cr) alloy clasps were fabricated using repeated laser sintering (RLS) and milling as one process simultaneously (hybrid manufacturing; HM). The surface roughness of the rest region, gap distances between clasp and tooth die, initial retentive forces, and changes of retentive forces up to 10,000 insertion/removal cycles were measured before and after heat treatment. The HM clasp was compared to the cast clasp and the clasp made by repeated laser sintering only without a milling process. Results: The HM clasp surface was smoother than those of cast and RLS clasps. With the digital relief, the fitness accuracy of the HM clasp improved. The retentive forces of the HM clasps with relief and after heat treatment were significantly greater than for the cast clasp. HM clasps demonstrated a constant or slight decrease of retention up to 10,000 cycles. Conclusions: HM clasp exhibited better fitness accuracy and retentive forces. The possibility of clinically using HM clasps as well as conventional cast clasps can be suggested. (C) 2018 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:342 / 346
页数:5
相关论文
共 50 条
  • [31] A microcomputed tomography evaluation of the marginal fit of cobalt-chromium alloy copings fabricated by new manufacturing techniques and alloy systems
    Kim, Eun-Ha
    Lee, Du-Hyeong
    Kwon, Sung-Min
    Kwon, Tae-Yub
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (03): : 393 - 399
  • [32] In vitro corrosion analyses of heat treated cobalt-chromium alloys manufactured by direct metal laser sintering
    Alifui-Segbaya, Frank
    Lewis, Jeffrey
    Eggbeer, Dominic
    Williams, Robert John
    RAPID PROTOTYPING JOURNAL, 2015, 21 (01) : 111 - 116
  • [33] Mechanical properties of cobalt-chromium 3-unit fixed dental prostheses fabricated by casting, milling, and additive manufacturing
    Olio, Marit
    Nesse, Harald
    Lundberg, Odd Johan
    Gjerdet, Nils Roar
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (01):
  • [34] Retention strength between veneering resin composites and laser-sintered cobalt-chromium alloy
    Kamada, Kohji
    Taira, Yohsuke
    Sumi, Tadateru
    Sawase, Takashi
    ODONTOLOGY, 2017, 105 (01) : 23 - 28
  • [35] Tensile strength and corrosion resistance of brazed and laser-welded cobalt-chromium alloy joints
    Zupancic, Rok
    Legat, Andraz
    Funduk, Nenad
    JOURNAL OF PROSTHETIC DENTISTRY, 2006, 96 (04): : 273 - 282
  • [36] Comparison and evaluation of marginal and internal gaps in cobalt-chromium alloy copings fabricated using subtractive and additive manufacturing
    Kim, Dong-Yeon
    Kim, Ji-Hwan
    Kim, Hae-Young
    Kim, Woong-Chul
    JOURNAL OF PROSTHODONTIC RESEARCH, 2018, 62 (01) : 56 - 64
  • [37] Physicomechanical properties of cobalt-chromium removable partial denture palatal major connectors fabricated by selective laser melting
    Salim, Safa
    Salleh, Nosizana Mohd
    Abidin, Zubaidah Zanul
    Yunus, Norsiah
    Rahmat, Rabiah
    Ibrahim, Norliza
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (03): : 530.e1 - 530.e7
  • [38] An investigation of force components in orthogonal cutting of medical grade cobalt-chromium alloy (ASTM F1537)
    Baron, Szymon
    Ahearne, Eamonn
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2017, 231 (04) : 269 - 275
  • [39] Marginal Accuracy of CAD/CAM Frameworks Fabricated by Presintered Cobalt-Chromium Alloy: A Systematic Review and Meta-analysis
    Nazarifar, Arezoo Mazaheri
    Davoudi, Amin
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2023, 38 (01) : 181 - 191
  • [40] Formation of a Calcium Phosphate Layer with Immobilized Cobalt Chromite Nanoparticles on Cobalt-Chromium Alloy by a Laser-Assisted Biomimetic Process
    Oyane, Ayako
    Sakamaki, Ikuko
    Koga, Kenji
    Nakamura, Maki
    APPLIED SCIENCES-BASEL, 2020, 10 (16):