Fitness and retentive force of cobalt-chromium alloy clasps fabricated with repeated laser sintering and milling

被引:44
|
作者
Torii, Mana [1 ]
Nakata, Toyoki [1 ]
Takahashi, Kazuya [1 ]
Kawamura, Noboru [2 ]
Shimpo, Hidemasa [1 ]
Ohkubo, Chikahiro [1 ]
机构
[1] Tsurumi Univ, Sch Dent Med, Dept Removable Prosthodont, Yokohama, Kanagawa, Japan
[2] Tsurumi Univ Dent Hosp, Dept Tech Training Inst, Yokohama, Kanagawa, Japan
关键词
CAD/CAM; Clasp; Relief; Retentive force; Heat treatment; COMPUTER-AIDED-DESIGN; RAPID PROTOTYPING TECHNIQUES; PARTIAL DENTURE FRAMEWORKS; CO-CR; MECHANICAL-PROPERTIES; DEFLECTION FATIGUE; MARGINAL ACCURACY; CAST CLASPS; TITANIUM; FIT;
D O I
10.1016/j.jpor.2018.01.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: With computer-aided design and computer-aided manufacturing (CAD/CAM), the study was conducted to create a removable partial denture (RPD) framework using repeated laser sintering rather than milling and casting techniques. This study experimentally evaluated the CAM clasp and compared it to a conventional cast clasp. Methods: After the tooth die was scanned, an Akers clasp was designed using CAD with and without 50 mm of digital relief on the occlusal surface of the tooth die. Cobalt-chromium (Co-Cr) alloy clasps were fabricated using repeated laser sintering (RLS) and milling as one process simultaneously (hybrid manufacturing; HM). The surface roughness of the rest region, gap distances between clasp and tooth die, initial retentive forces, and changes of retentive forces up to 10,000 insertion/removal cycles were measured before and after heat treatment. The HM clasp was compared to the cast clasp and the clasp made by repeated laser sintering only without a milling process. Results: The HM clasp surface was smoother than those of cast and RLS clasps. With the digital relief, the fitness accuracy of the HM clasp improved. The retentive forces of the HM clasps with relief and after heat treatment were significantly greater than for the cast clasp. HM clasps demonstrated a constant or slight decrease of retention up to 10,000 cycles. Conclusions: HM clasp exhibited better fitness accuracy and retentive forces. The possibility of clinically using HM clasps as well as conventional cast clasps can be suggested. (C) 2018 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:342 / 346
页数:5
相关论文
共 50 条
  • [1] Internal porosities, retentive force, and survival of cobalt-chromium alloy clasps fabricated by selective laser-sintering
    Schweiger, Josef
    Gueth, Jan-Frederik
    Erdelt, Kurt-Juergen
    Edelhoff, Daniel
    Schubert, Oliver
    JOURNAL OF PROSTHODONTIC RESEARCH, 2020, 64 (02) : 210 - 216
  • [2] An in vitro comparison of retentive force and deformation of acetal resin and cobalt-chromium clasps
    Arda, T
    Arikan, A
    JOURNAL OF PROSTHETIC DENTISTRY, 2005, 94 (03): : 267 - 274
  • [3] An Evaluation of Retentive Ability and Deformation of Acetal Resin and Cobalt-Chromium Clasps
    Meenakshi, A.
    Gupta, Ranjana
    Bharti, Vinay
    Sriramaprabu, G.
    Prabhakar, Ramachandra
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2016, 10 (01) : ZC37 - ZC41
  • [4] Retentive force and fitness accuracy of cobalt-chrome alloy clasps for removable partial denture fabricated with SLM technique
    Zhang, Manman
    Gan, Ning
    Qian, Haixin
    Jiao, Ting
    JOURNAL OF PROSTHODONTIC RESEARCH, 2022, 66 (03) : 459 - 465
  • [5] Selective laser melting and sintering technique of the cobalt-chromium dental alloy
    Stamenkovic, Dejan
    Obradovic-Duricic, Kosovka
    Rudolf, Rebeka
    Bobovnik, Rajko
    Stamenkovic, Dragoslav
    SRPSKI ARHIV ZA CELOKUPNO LEKARSTVO, 2019, 147 (11-12) : 664 - 669
  • [6] Deformation and retentive forces variations of the additively manufactured cobalt-chromium and titanium alloys dental clasps
    El-Tamimi, Kawkb M.
    Bayoumi, Dalia A.
    Alshenaiber, Rafif
    Aljulayfi, Ibrahim
    Ahmed, Mohamed M. Z.
    El-Sayed, Mohammed E.
    SAUDI DENTAL JOURNAL, 2024, 36 (06) : 947 - 953
  • [7] Comparison of the retentive characteristics of cobalt-chromium and commercially pure titanium clasps using a novel method
    Tse, Edward T. P.
    Cheng, Leo Y. Y.
    Luk, Henry W. K.
    Chu, Frederick C. S.
    Chai, John
    Chow, Tak W.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2006, 19 (04) : 371 - 372
  • [8] In vitro evaluation of the bond strength between various ceramics and cobalt-chromium alloy fabricated by selective laser sintering
    Bae, Eun-Jeong
    Kim, Hae-Young
    Kim, Woong-Chui
    Kim, Ji-Hwan
    JOURNAL OF ADVANCED PROSTHODONTICS, 2015, 7 (04): : 312 - 316
  • [9] CYCLIC FATIGUE PROPERTIES OF COBALT-CHROMIUM ALLOY CLASPS FOR PARTIAL REMOVABLE DENTAL PROSTHESES
    Cheng, Hui
    Xu, Minrui
    Zhang, Hai
    Wu, Weiqing
    Zheng, Ming
    Li, Xiurong
    JOURNAL OF PROSTHETIC DENTISTRY, 2010, 104 (06): : 389 - 396
  • [10] Characterisation of heat-treated cobalt-chromium alloy fabricated by selective laser melting
    Lambrou, I
    Kaldellis, A.
    Stergiou, V
    Tsakiridis, P. E.
    MATERIALS SCIENCE AND TECHNOLOGY, 2022, 38 (17) : 1510 - 1518