Ordered mesoporous carbon modified carbon ionic liquid electrode for the electrochemical detection of double-stranded DNA

被引:57
|
作者
Zhu, Zhihong [2 ,3 ]
Li, Xia [1 ]
Zeng, Yan [2 ,3 ]
Sun, Wei [1 ]
机构
[1] Qingdao Univ Sci & Technol, Coll Chem & Mol Engn, Qingdao 266042, Shandong, Peoples R China
[2] Huazhong Normal Univ, Inst Nanosci, Wuhan 430079, Peoples R China
[3] Huazhong Normal Univ, Ctr Technol, Wuhan 430079, Peoples R China
来源
BIOSENSORS & BIOELECTRONICS | 2010年 / 25卷 / 10期
基金
中国国家自然科学基金;
关键词
Nafion; Ordered mesoporous carbon; Carbon ionic liquid electrode; Double-stranded DNA; Direct electrochemistry; PASTE ELECTRODE; VOLTAMMETRIC DETERMINATION; L-CYSTEINE; NANOTUBES; BEHAVIOR; IMMOBILIZATION; OXIDATION; ADENINE; ACID;
D O I
10.1016/j.bios.2010.03.019
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this paper the direct electrochemistry of double-stranded DNA (dsDNA) was investigated on ordered mesoporous carbon (OMC) modified carbon ionic liquid electrode (CILE). CILE was prepared by mixing graphite powder with 1-ethyl-3-methylimidazolium ethylsulphate ([EMIM]EtOSO3) and liquid paraffin. A stable OMC film was formed on the surface of CILE with the help of Nafion to get a modified electrode denoted as Nafion-OMC/CILE. Due to the specific characteristics of OMC and IL present on the electrode surface, the fabricated electrode showed good electrochemical performances to different electroactive molecules. The electrochemical responses of dsDNA were carefully investigated on this electrode with two irreversible oxidation peak appeared at +1.250V and +0.921 V (vs. SCE), which was corresponding to the oxidation of adenine and guanine residues in dsDNA structure. The electrochemical behaviors of dsDNA were carefully investigated on the Nafion-OMC/CILE. Experimental results indicated that the electron transfer rate was promoted with the increase of the oxidation peak current and the decrease of the oxidation peak potential, which was due to the electrocatalytic ability of OMC on the electrode surface. Under the optimal conditions the oxidation peak current increased with dsDNA concentration in the range of 10.0-600.0 mu g mL(-1) by differential pulse voltammetry (DPV) with the detection limit of 1.2 mu g mL(-1) (3 sigma). (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2313 / 2317
页数:5
相关论文
共 50 条
  • [41] Electrochemical Detection of Rutin on Mg2Al-Cl Layered Double Hydroxide Modified Carbon Ionic Liquid Electrode
    Lou, Jin
    Yan, Lijun
    Wang, Wencheng
    Ruan, Chengxiang
    Hu, Anhui
    Sun, Wei
    [J]. JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2015, 62 (07) : 640 - 646
  • [42] Electrochemical behavior of methyl parathion and its sensitive determination at a glassy carbon electrode modified with ordered mesoporous carbon
    Deng Pan
    Shumin Ma
    Xiangjie Bo
    Liping Guo
    [J]. Microchimica Acta, 2011, 173 : 215 - 221
  • [43] Electrochemical behavior of methyl parathion and its sensitive determination at a glassy carbon electrode modified with ordered mesoporous carbon
    Pan, Deng
    Ma, Shumin
    Bo, Xiangjie
    Guo, Liping
    [J]. MICROCHIMICA ACTA, 2011, 173 (1-2) : 215 - 221
  • [44] Electrochemical Determination of Paraquat Using Ordered Mesoporous Carbon (CMK-3) Modified Glassy Carbon Electrode
    Rajaram, Rajendran
    Kumar, Sachin
    Ramanujam, Kothandaraman
    Neelakantan, Lakshman
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2023, 170 (08)
  • [45] An electrochemical biosensor based on a graphene oxide modified pencil graphite electrode for direct detection and discrimination of double-stranded DNA sequences
    Ahmadi, Mehran
    Ahour, Fatemeh
    [J]. ANALYTICAL METHODS, 2020, 12 (37) : 4541 - 4550
  • [46] Electrochemical Biosensor Based on Carbon Ionic Liquid Electrode Modified with Nafion/Hemoglobin/DNA Composite Film
    Sun, Wei
    Wang, Yan
    Li, Xiaoqing
    Wu, Jie
    Zhan, Tianrong
    Jiao, Kui
    [J]. ELECTROANALYSIS, 2009, 21 (22) : 2454 - 2460
  • [47] Poly(methylene blue) functionalized graphene modified carbon ionic liquid electrode for the electrochemical detection of dopamine
    Sun, Wei
    Wang, Yuhua
    Zhang, Yuanyuan
    Ju, Xiaomei
    Li, Guangjiu
    Sun, Zhenfan
    [J]. ANALYTICA CHIMICA ACTA, 2012, 751 : 59 - 65
  • [48] Electrochemical Behaviours and Detection of Adenosine-5′-triphosphate on an Ionic Liquid Modified Carbon Paste Electrode
    Niu, Qing-Juan
    Liu, Jun
    Li, Guang-Jiu
    Qin, Hong-Qing
    Gao, Hong-wei
    Sun, Wei
    [J]. JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2012, 59 (05) : 667 - 673
  • [49] Sensitive Electrochemical Determination of Catechol with a Graphene Modified Carbon Ionic Liquid Electrode
    Ruan, Chengxiang
    Li, Tongtong
    Wang, Xiuzheng
    Qi, Xiaowei
    Lou, Jin
    Gao, Weimin
    Sun, Wei
    [J]. JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2012, 59 (12) : 1584 - 1590
  • [50] Electrochemical properties and simultaneous determination of dihydroxybenzene isomers at ordered mesoporous carbon-modified electrode
    Jing Bai
    Liping Guo
    Jean Chrysostome Ndamanisha
    Bin Qi
    [J]. Journal of Applied Electrochemistry, 2009, 39 : 2497 - 2503