Attenuation correction of the PET ACR phantom using templates in PET/MR systems

被引:0
|
作者
Meier, Joseph [1 ]
Mawlawi, Osama [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Imaging Phys, Houston, TX 77030 USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
1995
引用
收藏
页数:2
相关论文
共 50 条
  • [21] Template based Attenuation Correction for PET in MR-PET Scanners
    Kops, Elena Rota
    Herzog, Hans
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3061 - 3064
  • [22] MR Imaging-Guided Attenuation Correction of PET Data in PET/MR Imaging
    Izquierdo-Garcia, David
    Catana, Ciprian
    PET CLINICS, 2016, 11 (02) : 129 - +
  • [23] Comparison of PET image quality using simultaneous PET/MR by attenuation correction with various MR pulse sequences
    Park, Chan Rok
    Lee, Youngjin
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2019, 51 (06) : 1610 - 1615
  • [24] Effect of Attenuation Correction on Regional Quantification Between PET/MR and PET/CT: A Multicenter Study Using a 3-Dimensional Brain Phantom
    Teuho, Jarmo
    Johansson, Jarkko
    Linden, Jani
    Hansen, Adam Espe
    Holm, Soren
    Keller, Sune H.
    Delso, Gaspar
    Veit-Haibach, Patrick
    Magota, Keiichi
    Saunavaara, Virva
    Tolvanen, Tuula
    Teras, Mika
    Iida, Hidehiro
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (05) : 818 - 824
  • [25] Advanced quantitative evaluation of PET systems using the ACR phantom and NiftyPET software
    Markiewicz, Pawel J.
    da Costa-Luis, Casper
    Dickson, J.
    Barnes, A.
    Krokos, G.
    MacKewn, J.
    Clark, T.
    Wimberley, C.
    MacNaught, G.
    Yaqub, M. M.
    Gispert, J. D.
    Hutton, B. F.
    Marsden, P.
    Hammers, A.
    Reader, A. J.
    Ourselin, S.
    Herholz, K.
    Matthews, J. C.
    Barkhof, F.
    MEDICAL PHYSICS, 2022, 49 (05) : 3298 - 3313
  • [26] NEMA image quality phantom measurements and attenuation correction in integrated PET/MR hybrid imaging
    Ziegler S.
    Jakoby B.W.
    Braun H.
    Paulus D.H.
    Quick H.H.
    EJNMMI Physics, 2 (1) : 1 - 14
  • [27] Improved MR to CT Synthesis for PET/MR Attenuation Correction Using Imitation Learning
    Klaser, Kerstin
    Varsavsky, Thomas
    Markiewicz, Pawel
    Vercauteren, Tom
    Atkinson, David
    Thielemans, Kris
    Hutton, Brian
    Cardoso, M. Jorge
    Ourselin, Sebastien
    SIMULATION AND SYNTHESIS IN MEDICAL IMAGING, SASHIMI 2019, 2019, 11827 : 13 - 21
  • [28] Supplemental transmission method for improved PET attenuation correction on an integrated MR/PET
    Watson, Charles C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 734 : 191 - 195
  • [29] Alternative methods for attenuation correction for PET images in MR-PET scanners
    Kops, Elena Rota
    Herzog, Hans
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4327 - 4330
  • [30] Repeatability of PET/CT image quality using the ACR PET phantom and the SNMMI phantom analysis toolkit.
    Vines, Douglass
    Driscoll, Brandon
    Keller, Harald
    JOURNAL OF NUCLEAR MEDICINE, 2022, 63