Salvage of a recurrently dislocating total hip prosthesis with use of a constrained acetabular component

被引:52
|
作者
Goetz, DD
Bremner, BRB
Callaghan, JJ
Capello, WN
Johnston, RC
机构
[1] Moines Orthopaed Surg, W Des Moines, IA 50266 USA
[2] Mayo Clin, Dept Orthoped Surg, Rochester, MN 55905 USA
[3] Univ Iowa Hlth Care, Dept Orthopaed Surg, Iowa City, IA 52242 USA
[4] Indiana Univ, Sch Med, Dept Orthopaed Surg, Indianapolis, IN 46202 USA
来源
关键词
D O I
10.2106/00004623-200411000-00009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We previously reported the results at a mean of five years following the use of a tripolar constrained acetabular component to treat recurrently dislocating total hip prostheses. In this study, we report the results after longer follow-up, with emphasis on the prevalence of implant loosening, osteolysis, and later recurrent instability. Fifty-five patients treated with a total of fifty-six constrained acetabular components because of recurrent dislocations of a total hip prosthesis (average, six dislocations; range, two to twenty dislocations) were followed for an average of 10.2 years (range, 7.0 to 13.2 years) or until death. Four (7%) of the fifty-six hips had a subsequent dislocation or failure of the device. Three femoral components (5%) and two acetabular components (4%) were revised because of aseptic loosening. One hip was revised because of osteolysis. We concluded that this constrained acetabular component provides durable protection against additional dislocations without substantial deleterious effects on component fixation. We use this device to treat recurrent dislocation when other modalities are unlikely to be effective.
引用
收藏
页码:2419 / 2423
页数:5
相关论文
共 50 条
  • [41] A REAPPRAISAL OF THE RING METAL-ON-METAL TOTAL HIP-PROSTHESIS - AN ARGUMENT FOR A STEMMED ACETABULAR COMPONENT DESIGN
    DESSOUKI, E
    YONGHING, K
    ROBERTSON, DE
    ALMS, M
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (02): : 331 - 331
  • [42] The use of plain radiography, subtraction arthrography, nuclear arthrography, and bone scintigraphy in the diagnosis of a loose acetabular component of a total hip prosthesis - A systematic review
    Temmerman, Olivier P. P.
    Raijmakers, Pieter G. H. M.
    Deville, Walter L.
    Berkhof, Johannes
    Hooft, Lotty
    Heyligers, Ide C.
    [J]. JOURNAL OF ARTHROPLASTY, 2007, 22 (06): : 818 - 827
  • [43] ACETABULAR RECONSTRUCTION WITH A THREADED PROSTHESIS FOR FAILED TOTAL HIP-ARTHROPLASTY
    MORE, RC
    AMSTUTZ, HC
    KABO, JM
    DOREY, FJ
    MORELAND, JR
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1992, (282) : 114 - 122
  • [44] THE RADIOLOGICAL ASSESSMENT OF ANTEVERSION OF SCREWED ACETABULAR COMPONENTS IN TOTAL HIP PROSTHESIS
    BRAUN, E
    MOLE, D
    SCHMITT, D
    [J]. REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1985, 71 (05): : 351 - 353
  • [45] Determining the orientation of acetabular prosthesis in total hip arthroplasty by refering to the anatomical landmarker of acetabular notches
    Heng Zhang
    Jiansheng Zhou
    Xiao Ling
    Haonan Chen
    Mingqiu Du
    Jianning Zhao
    [J]. Scientific Reports, 13
  • [46] Experimental and analytical validation of a modular acetabular prosthesis in total hip arthroplasty
    Romero F.
    Amirouche F.
    Aram L.
    Gonzalez M.H.
    [J]. Journal of Orthopaedic Surgery and Research, 2 (1)
  • [47] Total hip arthroplasty in post-dysplastic hip arthritis.: Can type and position of the acetabular component influence longevity of the prosthesis?
    Fousek, J.
    Indrakova, P.
    [J]. ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2007, 74 (01) : 47 - 54
  • [48] Determining the orientation of acetabular prosthesis in total hip arthroplasty by refering to the anatomical landmarker of acetabular notches
    Zhang, Heng
    Zhou, Jiansheng
    Ling, Xiao
    Chen, Haonan
    Du, Mingqiu
    Zhao, Jianning
    [J]. SCIENTIFIC REPORTS, 2023, 13 (01)
  • [49] The use of the transverse acetabular ligament in total hip replacement: An analysis of the orientation of the trial acetabular component using a navigation system
    Fujita, K.
    Kabata, T.
    Maeda, T.
    Kajino, Y.
    Iwai, S.
    Kuroda, K.
    Hasegawa, K.
    Tsuchiya, H.
    [J]. BONE & JOINT JOURNAL, 2014, 96B (03): : 306 - 311
  • [50] Radiographic evaluation of the zurich cementless total hip acetabular component
    Hanson, Steven P.
    Peck, Jeffrey N.
    Berry, Clifford R.
    Graham, John
    Stevens, Gary
    [J]. VETERINARY SURGERY, 2006, 35 (06) : 550 - 558