Development of a disposable cartridge real-time PCR test for detection of Chlamydia trachomatis directly from urine

被引:2
|
作者
Brennan, Desmond [1 ]
O'Connor, Louise [2 ]
Cormican, Martin [3 ]
Kileen, James [3 ]
Clancy, Eoin [2 ]
Smith, Terry J. [2 ]
Galvin, Paul [1 ]
机构
[1] Univ Coll Cork, Tyndall Natl Inst, Life Sci Interface Grp, Cork, Ireland
[2] Natl Univ Ireland, Mol Diagnost Res Grp, Galway, Ireland
[3] Hlth Serv Execut, Dublin, Ireland
关键词
Duplex PCR; Microfluidics; Fluorescence detection; Chlamydia trachomatis; MICROARRAY HYBRIDIZATION; MICROFLUIDIC DEVICE; RAPID DETECTION; GENOMIC DNA; AMPLIFICATION; INFECTION; SYSTEM; POINT;
D O I
10.1016/j.snb.2021.129873
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present a PCR assay screening Chlamydia trachomatis directly from urine without pre-amplification or sample clean-up and demonstrate suitability for implementation on a disposable cartridge system. Primers and probes were designed to detect all Chlamydia trachomatis serovars with a high degree of sensitivity and specificity. The assay also incorporated a synthetic internal amplification control to monitor inhibition of the PCR reaction. The assay protocol worked directly on urine samples with initial heating to 85 ?C for ten minutes, followed by a duplex realtime PCR (95 ?C, 55 ?C, 45 cycles) on resulting urine lysate. The test cartridge incorporated heating and liquid manipulation using pinch valves and a compressible blister pouch. Lyophilised PCR reagents were incorporated into the cartridge and were re-suspended by a 40 ?L aliquot of the urine lysate. Primers were designed to screen for all Chlamydia trachomatis serovars with a high degree of sensitivity and specificity. Evaluation of the newly developed PCR assay was carried out on the LightCyclerTM using urine samples previously confirmed positive or negative for the target pathogen, using the ABBOTT real-time PCR Cobas CT/NG test at a local hospital.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] DETECTION OF CHLAMYDIA PSITACI IN CAGE BIRDS IN SLOVENIA BY REAL-TIME PCR
    Marhold, Cvetka
    Slavec, Brigita
    Laroucau, Karine
    Vorimore, Fabien
    Racnik, Jozko
    Zadravec, Marko
    Kese, Darja
    Krapez, Uros
    Dovc, Alenka
    [J]. SLOVENIAN VETERINARY RESEARCH, 2012, 49 (04) : 185 - 192
  • [32] Evaluation of a Chlamydia trachomatis-specific, commercial, real-time PCR for use with ocular swabs
    Harry Pickering
    Martin J. Holland
    Anna R. Last
    Matthew J. Burton
    Sarah E. Burr
    [J]. Parasites & Vectors, 11
  • [33] Evaluation of a Chlamydia trachomatis-specific, commercial, real-time PCR for use with ocular swabs
    Pickering, Harry
    Holland, Martin J.
    Last, Anna R.
    Burton, Matthew J.
    Burr, Sarah E.
    [J]. PARASITES & VECTORS, 2018, 11
  • [34] Quantitative detection of respiratory Chlamydia pneumoniae infection by real-time PCR
    Kuoppa, Y
    Boman, J
    Scott, L
    Kumlin, U
    Eriksson, I
    Allard, A
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (06) : 2273 - 2274
  • [35] Rapid real-time PCR detection of HPdel directly from diluted blood samples
    Soejima, Mikiko
    Koda, Yoshiro
    [J]. CLINICAL CHEMISTRY, 2008, 54 (06) : 1095 - 1096
  • [36] A new generation of automated real time PCR assay for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae
    Yu, J.
    Marshall, R.
    Van der Pol, B.
    Williams, J. A.
    Schachter, J.
    Moncada, J.
    Ho, S.
    Welk, J.
    Lai-Zhang, J.
    Otis, K.
    Webb, E.
    Robinson, J.
    [J]. JOURNAL OF MOLECULAR DIAGNOSTICS, 2006, 8 (05): : 656 - 656
  • [37] Development of a multiplex TaqMan real-time PCR assay for the detection of Chlamydia psittaci and Chlamydia pneumoniae in human clinical specimens
    Wolff, Bernard J.
    Morrison, Shatavia S.
    Winchell, Jonas M.
    [J]. DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2018, 90 (03) : 167 - 170
  • [38] DETECTION OF CHLAMYDIA-TRACHOMATIS IN MEN URINE SPECIMENS BY USING A PCR ASSAY
    BIANCHI, A
    BRUNAT, N
    HENRY, S
    JANIER, M
    LASSAU, F
    MOREL, P
    SCIEUX, C
    [J]. CONTRACEPTION FERTILITE SEXUALITE, 1995, 23 (11): : 686 - 687
  • [39] Evaluation of four commercial real-time PCR assays for the detection of lymphogranuloma venereum in Chlamydia trachomatis-positive anorectal samples
    Touati, Arabella
    Laurier-Nadalie, Cecile
    Bebear, Cecile
    Peuchant, Olivia
    de Barbeyrac, Bertille
    [J]. CLINICAL MICROBIOLOGY AND INFECTION, 2021, 27 (06) : 909.e1 - 909.e5
  • [40] Quantitative detection of Escherichia coli from urine of patients with bacteriuria by real-time PCR
    Nobuyuki Hinata
    Toshiro Shirakawa
    Hiroshi Okada
    Katsumi Shigemura
    Sadao Kamidono
    Akinobu Gotoh
    [J]. Molecular Diagnosis, 2004, 8 (3) : 179 - 184