Arthrography of the shoulder: A modified ultrasound guided technique of joint injection at the rotator interval

被引:35
|
作者
Martins e Souza, Patricia [1 ]
Carvalho de Aguiar, Rodrigo Oliveira [2 ]
Marchiori, Edson [3 ]
Weiers Bardoe, Simon Alexander [4 ]
机构
[1] Rede Labs DOr, BR-22420030 Rio De Janeiro, Brazil
[2] Univ Fed Rio de Janeiro, BR-81020010 Curitiba, Parana, Brazil
[3] Univ Fed Rio de Janeiro, BR-25685120 Petropolis, RJ, Brazil
[4] Ctr Diagnost Dal Castel, BR-84500000 Irati, PR, Brazil
关键词
Ultrasound; MR arthrography; Shoulder; Rotator interval; GLENOHUMERAL JOINT; MR ARTHROGRAPHY; CUFF INTERVAL; GUIDANCE; ANTERIOR;
D O I
10.1016/j.ejrad.2009.03.020
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To describe an ultrasound guided technique of shoulder joint injection at the rotator interval space, using an endocavitary transducer and performed by a radiologist with no previous experience with arthrography. Materials: and method Accuracy of the intra-articular puncture and incidence of complications were evaluated in 180 consecutive patients submitted to joint puncture for shoulder MR arthrography. Results: Puncture was accomplished successfully in all cases, of which 92% with one attempt, and 8% with two, both well tolerated by patients. No relevant complications were reported after the procedure. Conclusion: This study has shown that puncture of the glenohumeral joint guided by ultrasound at the rotator interval space using an endocavitary transducer is easy and quick, even when performed by radiologists with no experience in arthrographic procedures. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:E30 / E33
页数:4
相关论文
共 50 条
  • [41] MR arthrography of the shoulder: Fluoroscopically guided technique using a posterior approach
    Farmer, KD
    Hughes, PM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (02) : 433 - 434
  • [42] The Rotator Interval Bursa (RIB) Technique: Sequential Rotator Interval and Subacromial Subdeltoid Bursa Injection
    Nischal, Neha
    Mishra, Chetna
    Singh, Jatinder Pal
    INDIAN JOURNAL OF RADIOLOGY AND IMAGING, 2024,
  • [43] Fluoroscopy-Guided Sacroiliac Joint Injection: Description of a Modified Technique
    Kasliwal, Prasad Jaychand
    Kasliwal, Sapana
    PAIN PHYSICIAN, 2016, 19 (02) : E329 - E337
  • [44] Adhesive Capsulitis. The Effect Of 1 Ultrasound Guided Injection Of 20 Mg Triamcinolone Into The Rotator Interval
    Juel, Niels Gunnar
    Oland, Gunnar
    Kvalheim, Synnove K.
    Ekeberg, Ole M.
    Kristiansen, Siri A.
    Love, Tormod
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 : 193 - 193
  • [45] Windshield Wiper in the Shoulder: Ultrasound Imaging for the Proximal Rotator Cuff Interval
    Ricci, Vincenzo
    Ozcakar, Levent
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2019, 98 (03) : E27 - E27
  • [46] THE ANATOMY OF THE SHOULDER JOINT ON CT ARTHROGRAPHY AND THE ROLE OF THE TECHNIQUE IN RECURRENT DISLOCATION
    COOK, JV
    TAYAR, R
    CLINICAL RADIOLOGY, 1988, 39 (06) : 682 - 682
  • [47] Ultrasound-Guided Shoulder Injection or Ultrasound Guides the Shoulder Injection? Standard Versus State-of-the-Art
    Sekizkardes, Merve
    Aydin, Gulumser
    Ozcakar, Levent
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2018, 97 (05) : E46 - E46
  • [48] Accuracy of shoulder joint injections with ultrasound guidance: Confirmed by magnetic resonance arthrography
    Kuratani, Kosuke
    Tanaka, Makoto
    Hanai, Hiroto
    Hayashida, Kenji
    WORLD JOURNAL OF ORTHOPEDICS, 2022, 13 (03): : 259 - 266
  • [49] Ultrasound-Guided Gadolinium Joint Injections for Magnetic Resonance Arthrography
    Choudur, Hema Nalini
    Ellins, Mary Lou
    JOURNAL OF CLINICAL ULTRASOUND, 2011, 39 (01) : 6 - 11
  • [50] Ultrasound guided sacroiliac joint injection in pregnancy
    McHugh, R.
    Schwendemann, W.
    Hurdle, M.
    ANESTHESIOLOGY, 2007, 106 (05) : B82 - B82