Influence of cathodic protection and transmission-line proximity on oil-flow electrification

被引:0
|
作者
Metwally, IA [1 ]
机构
[1] Mansoura Univ, Dept Elect Engn, Mansoura 35516, Egypt
来源
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Two reduced-scale closed oil cycles are used to investigate the influence of both the cathodic protection of a pipeline and its proximity to AC power transmission lines on the oil-flow electrification (OFE). For the former case, the results reveal that the OFE is highly dependent on the magnitude of the protection current. The higher the protection voltage the higher is the OFE. Also, the results show that the OFE is enhanced by oil velocity and/or temperature. For the latter case, the results indicate that conductor bundling has a monumental impact on all measured quantities: pipe floating potential, and both corona and streaming currents. In addition,, oil temperature causes evident quantitative as well as qualitative changes in the measured streaming current, but no effect was found on both pipe floating potential and corona current. The results are interpreted in terms of physico-chemical and electrochemistry point of view together with electric field computation using a program based on charge simulation method.
引用
收藏
页码:243 / 252
页数:10
相关论文
共 50 条
  • [2] Oil-flow Electrification Phenomenon in EHV Power Transformers and Restrain Measures
    Hu Hanmei
    Zeng Conghai
    Li Guang
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [3] Measurement of currents and floating potential in multilayer sensor due to oil-flow electrification
    Metwally, I. A.
    Leblanc, P.
    Paillat, T.
    JOURNAL OF ELECTROSTATICS, 2013, 71 (06) : 1061 - 1067
  • [4] CORRELATION METHOD FOR TRANSMISSION-LINE PROTECTION
    VITINS, M
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1978, 97 (05): : 1607 - 1617
  • [5] Calculation of transmission line cathodic protection
    Ivanov, VT
    Shamsutdinova, TM
    NEFTYANOE KHOZYAISTVO, 1997, (08): : 53 - 55
  • [6] Analysis on oil-flow electrification phenomenon in 1000 kV UHV transformer and restrain measure
    Li, Zhong-Quan
    Xu, Peng
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (04): : 907 - 911
  • [7] SAMPLING RATES FOR COMPUTER TRANSMISSION-LINE PROTECTION
    HOPE, GS
    MALIK, OP
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1975, 94 (06): : 1922 - 1922
  • [8] Adaptive Current Differential Protection Schemes for Transmission-Line Protection
    Dambhare, Sanjay
    Soman, S. A.
    Chandorkar, M. C.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (04) : 1832 - 1841
  • [9] A PROCEDURE FOR DESIGNING COMMUNICATION-LINE PROTECTION FROM THE DANGEROUS INFLUENCE OF A POWER TRANSMISSION-LINE
    KOSTENKO, MV
    ELECTRICAL TECHNOLOGY, 1984, (02): : 1 - 14
  • [10] Adaptive Current Differential Protection Schemes for Transmission-Line Protection
    Dambhare, Sanjay
    Soman, Shreevardhan
    Chandorkar, Mukul
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,