Glycosylated Gadolinium as Potential Metabolic Contrast Agent vs Gd-DTPA for Metabolism of Tumor Tissue in Magnetic Resonance Imaging

被引:5
|
作者
Heydarnezhadi, Sara [1 ]
Alam, Nader Riahi [1 ]
Haghgoo, Soheila [2 ]
Ghanaati, Hossein [3 ]
Khoobi, Mehdi [4 ]
Gorji, Ensiyeh [2 ]
Rafiei, Behrooz [3 ]
Nikfari, Banafsheh [1 ]
Amirrashedi, Mahsa [1 ]
机构
[1] Univ Tehran Med Sci, Sch Med, Med Phys & Biomed Engn Dept, Keshavaz Blvd,16 Azar St, Tehran 14145, Iran
[2] Minist Hlth, Food & Drug Org, Dept Pharmaceut, Food & Drug Lab Res Ctr, Imam St, Tehran 1113615911, Iran
[3] Univ Tehran Med Sci, Sch Med, Med Imaging Ctr, Imam Hosp Complex,Keshavaz Blvd, Tehran 1419733141, Iran
[4] Univ Tehran Med Sci, Pharmaceut Sci Res Ctr, Tehran 14176, Iran
关键词
CANCER; TRANSPORTERS;
D O I
10.1007/s00723-015-0756-2
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Modern imaging technologies such as mMRI employ contrast agents to visualize the tumor microenvironment; therefore, demand for contrast agents, with an enhanced sensitivity and tissue tumor-specific target, is very high. The purpose of this study synthesizes novel metabolic contrast agent (Gd-DTPA-DG) and evaluates accumulation in tumor tissue for early diagnostic cancer. The contrast agent was synthesized and characterized with using different techniques including dynamic light scattering, high resolution transmission electron microscopy, Fourier transform infrared spectroscopy and inductively coupled plasma atomic emission spectroscopy (ICP-AES). Finally, MRI imaging performed to determine in vitro and in vivo relaxometry. Gd-DTPA-DG was specifically investigated in tissue tumor over a 45 min in vivo because of its ability to target metabolically active tumor tissue, and comparison with conventional contrast agent [Gd-DTPA (Magnevist, Bayer-USA)]. According to the result, the maximum image signal intensity in different concentrations (0.02 to approximately 0.8 mM), longitudinal relaxation time (T (1)) and transverse relaxation time (T (2)) were obtained. Signal intensity of tumor tissue was shown at 15 and 30 min after injection reaches maximum for Gd-DTPA-DG and Gd-DTPA (Magnevist, Bayer-USA), respectively. But Gd-DTPA-DG shown signal intensity higher of Gd-DTPA (Magnevist, Bayer-USA) over 45 min, comparison with Gd-DTPA (Magnevist, Bayer-USA). Images showed metabolic contrast agent penetrate into cells and accumulated in tumor. These results showed that the novel metabolic contrast agent could become a useful tool in early detection of cancer.
引用
收藏
页码:375 / 385
页数:11
相关论文
共 50 条
  • [21] ALBUMIN LABELED WITH GD-DTPA - AN INTRAVASCULAR CONTRAST-ENHANCING AGENT FOR MAGNETIC-RESONANCE BLOOD POOL IMAGING - PREPARATION AND CHARACTERIZATION
    OGAN, MD
    SCHMIEDL, U
    MOSELEY, ME
    GRODD, W
    PAAJANEN, H
    BRASCH, RC
    INVESTIGATIVE RADIOLOGY, 1987, 22 (08) : 665 - 671
  • [22] Gadolinium Labeled Glycosylated Nanomagnetic Particles as Metabolic Contrast Agents in Molecular Magnetic Resonance Imaging
    Heydarnezhadi, S.
    Riyahi-Alam, N.
    Haghoo, S.
    Khobi, M.
    Nikfar, B.
    Gorji, E.
    Rafiei, B.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 119 - 122
  • [23] MAGNETIC-RESONANCE IMAGING OF THE PAROTID-GLAND - DIAGNOSIS BY PLAIN IMAGING AND WITH CONTRAST-MEDIUM GD-DTPA
    VOGL, T
    DRESEL, S
    KANG, K
    GREVERS, G
    RIEDERER, A
    SPATH, M
    LISSNER, J
    DIGITALE BILDDIAGNOSTIK, 1989, 9 (02): : 59 - 68
  • [24] Effects of the Magnetic Resonance Imaging Contrast Agent Gd-DTPA on Plant Growth and Root Imaging in Rice (vol 9, e100246, 2014)
    Liu, Z.
    Qian, J.
    Liu, B.
    Wang, Q.
    Ni, X.
    Dong, Y.
    PLOS ONE, 2015, 10 (04):
  • [25] MR IMAGING OF CORPUS CARCINOMA WITH AND WITHOUT APPLICATION OF THE PARAMAGNETIC CONTRAST AGENT GD-DTPA
    ROTH, G
    SUNDERMEYER, R
    GEBURTSHILFE UND FRAUENHEILKUNDE, 1986, 46 (11) : 790 - 795
  • [26] MAGNETIC-RESONANCE-IMAGING OF HUMAN CEREBRAL INFARCTION - ENHANCEMENT WITH GD-DTPA
    IMAKITA, S
    NISHIMURA, T
    NAITO, H
    YAMADA, N
    YAMAMOTO, K
    TAKAMIYA, M
    YAMADA, Y
    SAKASHITA, Y
    MINAMIKAWA, J
    KIKUCHI, H
    TERADA, T
    NEURORADIOLOGY, 1987, 29 (05) : 422 - 429
  • [27] Gadolinium-mesoporous Silica as a Potential Magnetic Resonance Imaging Contrast Agent
    Eddy, Diana Rakhmawaty
    Anggraeni, Anni
    Fauzia, Retna Putri
    Rahayu, Iman
    Mutalib, Abdul
    Firdaus, M. Lutfi
    Bahti, Husein Hernandi
    ORIENTAL JOURNAL OF CHEMISTRY, 2018, 34 (05) : 2603 - 2607
  • [28] TETRA-P-AMINOPHENYLPORPHYRIN CONJUGATED WITH GD-DTPA - TUMOR-SPECIFIC CONTRAST AGENT FOR MR-IMAGING
    HINDRE, F
    LEPLOUZENNEC, M
    DECERTAINES, JD
    FOULTIER, MT
    PATRICE, T
    SIMONNEAUX, G
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (01): : 59 - 65
  • [29] The effects of three different contrast agents (Gd-BOPTA, Gd-DTPA, and Gd-DOTA) on brachial plexus magnetic resonance imaging
    Zhang, Xiaojing
    Wang, Wensheng
    Liu, Tiefang
    Qi, Yeqing
    Ma, Lin
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (04)
  • [30] Comparison of BOLD contrast and Gd-DTPA dynamic contrast-enhanced imaging in rat prostate tumor
    Jiang, L
    Zhao, DW
    Constantinescu, A
    Mason, RP
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (05) : 953 - 960