Real-Time Shear Wave Ultrasound Elastography Differentiates Fibrotic from Inflammatory Strictures in Patients with Crohn's Disease

被引:60
|
作者
Chen, Yu-jun [1 ]
Mao, Ren [1 ,2 ]
Li, Xue-hua [3 ]
Cao, Qing-hua [4 ]
Chen, Zhi-hui [5 ]
Liu, Bao-xian [1 ]
Chen, Shu-ling [1 ]
Chen, Bai-li [2 ]
He, Yao [2 ]
Zeng, Zhi-rong [2 ]
Ben-Horin, Shomron [2 ,6 ,7 ]
Rimola, Jordi [8 ]
Rieder, Florian [9 ]
Xie, Xiao-yan [1 ,2 ]
Chen, Min-hu [2 ]
机构
[1] Sun Yat Sen Univ, Affiliated Hosp 1, Dept Med Ultrason, Guangzhou, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Affiliated Hosp 1, Dept Gastroenterol, 58 Zhongshan 2 Rd, Guangzhou 510080, Guangdong, Peoples R China
[3] Sun Yat Sen Univ, Affiliated Hosp 1, Dept Radiol, Guangzhou, Guangdong, Peoples R China
[4] Sun Yat Sen Univ, Affiliated Hosp 1, Dept Pathol, Guangzhou, Guangdong, Peoples R China
[5] Sun Yat Sen Univ, Affiliated Hosp 1, Dept Gen Surg, Guangzhou, Guangdong, Peoples R China
[6] Tel Aviv Univ, Dept Gastroenterol, Sheba Med Ctr, Tel Aviv, Israel
[7] Tel Aviv Univ, Sackler Sch Med, Tel Aviv, Israel
[8] Univ Barcelona, Hosp Clin Barcelona, Dept Radiol, IDIBAPS, Barcelona, Spain
[9] Cleveland Clin, Dept Gastroenterol Hepatol & Nutr, Digest Dis & Surg Inst, Cleveland, OH 44106 USA
基金
中国国家自然科学基金;
关键词
stricture; Crohn's disease; elastography; CONTRAST-ENHANCED ULTRASOUND; POPULATION-BASED COHORT; THYROID-NODULES; COMPUTED-TOMOGRAPHY; NATURAL-HISTORY; BOWEL DISEASES; FIBROSIS; US; ULTRASONOGRAPHY; DIAGNOSIS;
D O I
10.1093/ibd/izy115
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and aim: The distinction of intestinal fibrosis from inflammation in Crohn's disease (CD) associated strictures has important therapeutic implications. Ultrasound elastography is useful in evaluating the degree of fibrosis in liver, but there is little evidence whether it can assess fibrosis in the bowel. We determined whether shear-wave elastography (SWE), a novel modification of elastography, quantifying tissue stiffness, could differentiate between inflammatory and fibrotic components in strictures of patients with CD. Methods: Consecutive CD patients with ileal/ileocolonic strictures who underwent SWE within 1 week to surgical resection were enrolled. The SWE value of the stenotic bowel wall was compared to the grade and severity of fibrosis and inflammation, respectively, in the resected bowel specimen. Results: Thirty-five patients were enrolled. The mean SWE value of stenotic bowel wall was significantly higher in severe fibrosis (23.0 +/- 6.3 Kpa) than that in moderate (17.4 +/- 3.8 Kpa) and mild fibrosis (14.4 +/- 2.1 Kpa)(P = 0.008). Using 22.55 KPa as the cutoff value in discriminating between mild/moderate and severe fibrosis, the sensitivity and specificity was 69.6% and 91.7% with an area under the curve (AUC) of 0.822 (P = 0.002). However, no significant difference regarding mean SWE existed among different grades of inflammation. The sensitivity and specificity of bowel vascularization score on conventional ultrasound in differentiating severe inflammation from mild/moderate was 87.5% and 57.9% with AUC of 0.811 (P = 0.002). Combining SWE and conventional ultrasound (bowel vascularization score), we propose a bowel ultrasound classification of intestinal strictures. A moderate agreement between ultrasound and pathological classification was observed (kappa = 0.536, P < 0.001). Conclusions: This pilot study suggests that SWE is feasible and accurate in detecting intestinal fibrosis in patients with CD. After validation, combing SWE and bowel vascularization on conventional ultrasound might be applied to guide a management strategy in CD patients through defining the type of intestinal stricture.
引用
收藏
页码:2183 / 2190
页数:8
相关论文
共 50 条
  • [1] Real-time Shear Wave Ultrasound Elastography in distinguishing inflammatory from fibrotic stenosis in Crohn's disease
    Chen, Y. -J.
    Mao, R.
    He, Y.
    Chen, B. -L.
    Zeng, Z. -R.
    Xie, X. -Y.
    Chen, M. -H.
    JOURNAL OF CROHNS & COLITIS, 2015, 9 : S192 - S192
  • [2] BASELINE BOWEL STIFFNESS ON REAL-TIME SHEAR WAVE ULTRASOUND ELASTOGRAPHY PREDICTS RESPONSE TO INFLIXIMAB IN PATIENTS WITH CROHN'S DISEASE
    Mao, Ren
    Chen, Yu-Jun
    Ben-Horin, Shomron
    Xie, Xiao-yan
    Chen, Minhu
    GASTROENTEROLOGY, 2019, 156 (06) : S381 - S382
  • [3] Ultrasound Shear Wave Elastography and Contrast Enhancement: Effective Biomarkers in Crohn's Disease Strictures
    Lu, Cathy
    Gui, Xianyong
    Chen, Wenqian
    Fung, Tak
    Novak, Kerri
    Wilson, Stephanie R.
    INFLAMMATORY BOWEL DISEASES, 2017, 23 (03) : 421 - 430
  • [4] ULTRASOUND ELASTOGRAPHY FOR THE DETECTION OF FIBROTIC BOWEL STRICTURES IN PATIENTS WITH CROHN'S DISEASE: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Marasco, Giovanni
    Vestito, Amanda
    Maconi, Giovanni
    Festi, Davide
    Bazzoli, Franco
    Zagari, Rocco Maurizio
    GUT, 2019, 68 : A79 - A79
  • [5] REAL-TIME SONOELASTOGRAPHY IN THE DIFFERENTIAL DIAGNOSIS OF FIBROTIC FROM INFLAMMATORY CROHN'S STRICTURES: PRELIMINARY RESULTS OF A SINGLE CENTER STUDY
    Sconfienza, L. M.
    Cavallaro, F.
    Colombi, V.
    Pastorelli, L.
    Tontini, G. E.
    Spina, L.
    Vecchi, M.
    DIGESTIVE AND LIVER DISEASE, 2015, 47 : E205 - E205
  • [6] Role of Ultrasound Elastography in the Detection of Fibrotic Bowel Strictures in Patients with Crohn's Disease: Systematic Review and Meta-Analysis
    Vestito, Amanda
    Marasco, Giovanni
    Maconi, Giovanni
    Festi, Davide
    Bazzoli, Franco
    Zagari, Rocco Maurizio
    ULTRASCHALL IN DER MEDIZIN, 2019, 40 (05): : 646 - 654
  • [7] Ultrasound elastography-derived shear wave velocity helps distinguish acutely inflamed from fibrotic bowel in patients with Crohn's disease receiving surgery
    Mao, R.
    Chen, Y.
    Chen, B.
    He, Y.
    Xie, X.
    Zeng, Z.
    Ben-Horin, S.
    Chen, M.
    Xie, X.
    JOURNAL OF CROHNS & COLITIS, 2016, 10 : S195 - S195
  • [8] US-based Real-time Elastography for the Detection of Fibrotic Gut Tissue in Patients with Stricturing Crohn Disease
    Baumgart, Daniel C.
    Mueller, Hans P.
    Grittner, Ulrike
    Metzke, Diana
    Fischer, Andreas
    Guckelberger, Olaf
    Pascher, Andreas
    Sack, Ingolf
    Vieth, Michael
    Rudolph, Birgit
    RADIOLOGY, 2015, 275 (03) : 889 - 899
  • [9] Real-time ultrasound shear wave elastography using a local phase gradient
    González-Mateo, Enrique
    Camarena, Francisco
    Jiménez, Noé
    Computer Methods and Programs in Biomedicine, 2025, 260
  • [10] Transvaginal Real-time Shear Wave Elastography in the Diagnosis of Cervical Disease
    Liu, Chun
    Li, Ting Ting
    Hu, Ziyue
    Li, Yuan
    Cheng, Xueqing
    Zhu, Yi
    Lu, Man
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (12) : 3173 - 3181