Mechanical behaviour of connections between CLT panels under monotonic and cyclic loading

被引:3
|
作者
Xiong, H. B. [1 ]
Huynh, A. [1 ,2 ]
机构
[1] Tongji Univ, Coll Civil Engn, Shanghai 200092, Peoples R China
[2] Natl Inst Appl Sci Lyon, Dept Civil Engn & Urban Planning, F-69621 Villeurbanne, France
关键词
D O I
10.1088/1755-1315/153/4/042014
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The experimental research presented in this paper investigates the mechanical behaviour of commercial metal connections in three-ply Chinese-manufactured cross-laminated timber (CLT) panels. Monotonic and cyclic loading tests were conducted at Tongji University on angle bracket and joints with inclined self-tapping screws. According to the standard EN 12512, the force-displacement curves are exploited to assess the mechanical properties of the connections such as the strength capacity, yielding point, ductility and equivalent damping ratios. From the test results, the main load-carrying direction of the angle bracket is shear direction but the connection exhibits more ductile and dissipative behaviour in tension direction. In general, screwed joints demonstrate relatively brittle behaviour except in the case of shear wall-to-wall connection. Based on the capacity-based design principles, the experimental results and the failure modes are discussed to propose some design suggestions.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Behaviour of cold-formed steel shear wall panels under monotonic and reversed cyclic loading
    Nithyadharan, M.
    Kalyanaraman, V.
    THIN-WALLED STRUCTURES, 2012, 60 : 12 - 23
  • [22] Mechanical behavior of ballast under monotonic and cyclic loading
    Karraz, K.
    Bonnet, G.
    Dupla, J. C.
    Canon, J.
    ADVANCED CHARACTERISATION OF PAVEMENT SOIL ENGINEERING MATERIALS, VOLS 1 AND 2, 2007, : 1847 - 1856
  • [23] Inhomogeneous mechanical behaviour of concrete subjected to monotonic and cyclic loading
    Song, Zhengyang
    Fruehwirt, Thomas
    Konietzky, Heinz
    INTERNATIONAL JOURNAL OF FATIGUE, 2020, 132
  • [24] Experimental Characterization of Monotonic and Cyclic Loading Responses of CLT Panel-To-Foundation Angle Bracket Connections
    Tomasi, Roberto
    Smith, Ian
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2015, 27 (06)
  • [25] Behaviour of composite walls under monotonic and cyclic shear loading
    Hossain, KMA
    Wright, HD
    STRUCTURAL ENGINEERING AND MECHANICS, 2004, 17 (01) : 69 - 85
  • [26] Behaviour of CFRP strengthened CHS members under monotonic and cyclic loading
    Tafsirojjaman, T.
    Fawzia, Sabrina
    Thambiratnam, David
    Zhao, Xiao-Ling
    COMPOSITE STRUCTURES, 2019, 220 : 592 - 601
  • [27] Limited flow behaviour of sand with fines under monotonic and cyclic loading
    Lo, S. R.
    Rahman, M. D. Mizanur
    Bobei, D.
    GEOTECHNICAL ENGINEERING FOR DISASTER MITIGATION AND REHABILITATION, 2008, : 201 - +
  • [28] Nonlinear Mechanical Behavior of Natural Argillite under Monotonic and Cyclic Loading
    Yang, Diansen
    Chanchole, Serge
    Valli, Pierre
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2013, 25 (08) : 1089 - 1096
  • [29] Mechanical behavior of nylon 66 fibers under monotonic and cyclic loading
    Averett, Rodney D.
    Realff, Mary L.
    Michielsen, Stephen
    Neu, Richard W.
    COMPOSITES SCIENCE AND TECHNOLOGY, 2006, 66 (11-12) : 1671 - 1681
  • [30] Comparison of behaviour between channel and angle shear connectors under monotonic and fully reversed cyclic loading
    Shariati, Mahdi
    Sulong, N. H. Ramli
    Suhatril, Meldi
    Shariati, Ali
    Khanouki, M. M. Arabnejad
    Sinaei, Hamid
    CONSTRUCTION AND BUILDING MATERIALS, 2013, 38 : 582 - 593