Performance Analysis of High Voltage Transmission Line Insulators in Highly Polluted Southern Coastal Areas of Pakistan

被引:0
|
作者
Unar, Naveed Ahmed [1 ]
Mirjat, Nayyar Hussain [2 ]
Uqaili, Mohammad Aslam [2 ]
Usman, Salis [1 ]
Shaikh, Muhammad Zakir [2 ]
机构
[1] Natl Transmiss & Despatch Co NTDC, Power Syst Planning Dept, Lahore, Pakistan
[2] Mehran Univ Engn & Technol, Dept Elect Engn, Jamshoro, Pakistan
关键词
Disc Insulator; Transmission; Power; Flashover;
D O I
10.1109/GCWOT49901.2020.9391630
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This paper presents performance analysis of high voltage transmission line disc insulators installed on 220 KV and 500 KV transmission line towers in highly contaminated and thus polluted southern coastal areas of Pakistan. This study is based on case studies carried out on three 500 KV transmission lines and two 220 KV transmission lines to investigate the effects of Room- Temperature Vulcanized (RTV) Silicon Coating on disc insulators in mitigating tripping and power outages resulting from pollution flashover. The flashover inhering from atmosphere in high voltage disc insulators on high power transmission lines is a major bottleneck in smooth power evacuation of electrical power. The improving behavior of transmission lines resulting in reduced tripping and reduced maintenance cost in terms of lesser power outages in the aftermath of replacement of faulty and poor condition disc insulators is also studied and results are concluded. Mitigation of frequent tripping and power outages occurring from flashovers due to environmental constraints is possible by either employing Room-Temperature Vulcanized Silicon and Polymer Coating of disc insulators or replacing poor quality disc insulators with good quality disc insulators.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Performance Analysis of High Voltage Insulators Surface Condition Using Time-frequency Distribution
    Sulaiman, A.
    Abdullah, A. R.
    Aman, A.
    Norddin, N.
    Abidin, N. Q. Zainal
    PROCEEDINGS OF THE 2013 IEEE 7TH INTERNATIONAL POWER ENGINEERING AND OPTIMIZATION CONFERENCE (PEOCO2013), 2013, : 603 - 607
  • [32] Metal Contamination Distribution Detection in High-Voltage Transmission Line Insulators by Laser-induced Breakdown Spectroscopy (LIBS)
    Wang, Naixiao
    Wang, Xilin
    Chen, Ping
    Jia, Zhidong
    Wang, Liming
    Huang, Ronghui
    Lv, Qishen
    SENSORS, 2018, 18 (08)
  • [33] On-line monitoring, data analysis for electrolytic corrosion of ±800 kV high voltage direct current insulators
    Yang, Daiming
    Cao, Bin
    Li, Zong
    Yang, Lianwu
    Wu, Yankun
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2021, 131
  • [34] WAVELET ANALYSIS IN TRANSIENT BASED PROTECTION FOR POWER SYSTEM HIGH VOLTAGE TRANSMISSION LINE
    Xia, Ming-Chao
    Huang, Yi-Zhuang
    PROCEEDINGS OF THE 2010 INTERNATIONAL CONFERENCE ON WAVELET ANALYSIS AND PATTERN RECOGNITION, 2010, : 427 - 430
  • [35] Insulation Performance of a High -Voltage Compact Overhead Transmission Line subject to Tropical Savanna Wildfires
    Berredo, Alessandro
    Smith, Michael
    2023 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, PESGM, 2023,
  • [36] Seismic performance analysis of ultra-high voltage transmission tower-line system based on capacity spectrum method
    Wang, Wenming
    Sheng, Hanke
    Gao, Yahui
    Zhang, Shibo
    STRUCTURES, 2024, 61
  • [37] Flashover Possibility Analysis of Overhead Power Transmission and Distribution Line Insulators with the Excitation of High Altitude Electromagnetic Pulse
    Zhang H.
    Zou J.
    Tian B.
    Wu M.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2020, 35 (02): : 435 - 443
  • [38] Prediction of Flashover and Pollution Severity of High Voltage Transmission Line Insulators Using Wavelet Transform and Fuzzy C-Means Approach
    Narayanan, V. Jayaprakash
    Sivakumar, M.
    Karpagavani, K.
    Chandrasekar, S.
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2014, 9 (05) : 1677 - 1685
  • [39] Comparative Performance Analysis of Different Wind Fields in the Southern and North-western Coastal Areas of the Black Sea
    Cakmak, Recep Emre
    Akpinar, Adem
    Van Vledder, Gerbrant Ph
    MEDITERRANEAN MARINE SCIENCE, 2019, 20 (02): : 427 - 452
  • [40] Analysis of electric field during insulators exchange on working high voltage 220 kV line in aspect of human hazard
    Nadolny, Zbigniew
    Rakowska, Aleksandra
    PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (05): : 200 - 203