A new bioassay method for quantitative analysis of tetracyclines

被引:3
|
作者
Rodriguez, N [1 ]
Roig, S [1 ]
Olmedo, N [1 ]
Lorén, JG [1 ]
Rius, N [1 ]
机构
[1] Univ Barcelona, Fac Farm, Dept Microbiol & Parasitol, E-08028 Barcelona, Spain
关键词
bioassay; pH response; tetracyclines;
D O I
10.1007/s10295-004-0158-1
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A new method is described for quantitative analysis of tetracycline, based on the decrease in external pH of bacterial suspensions after the addition of a glucose pulse. The decrease in external pH of these suspensions was inversely proportional to the concentration of tetracycline. The correlation coefficient of standard response lines derived from the bioassay was 0.99. Tetracycline potency was determined in six tetracycline HCl samples by the sugar pulse bioassay and a turbidimetric method. The turbidimetric assay result varied from the glucose-pulse data by no more than 7 and 3% at 3 and 7 min, respectively. The procedure is rapid, precise and quantitative, and requires minimal preparation and use of media, with savings in laboratory resources and time.
引用
收藏
页码:379 / 383
页数:5
相关论文
共 50 条
  • [41] DIGITAL AMPLITUDE INTERVAL ANALYSIS . A NEW METHOD OF QUANTITATIVE ANALYSIS OF EEG
    BENTE, D
    FERNER, U
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1969, 27 (06): : 628 - &
  • [42] A new quantitative method for gunshot residue analysis by ion beam analysis
    Christopher, Matthew E.
    Warmenhoeven, John-William
    Romolo, Francesco S.
    Donghi, Matteo
    Webb, Roger P.
    Jeynes, Christopher
    Ward, Neil I.
    Kirkby, Karen J.
    Bailey, Melanie J.
    ANALYST, 2013, 138 (16) : 4649 - 4655
  • [43] New uses for tetracyclines
    不详
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1997, 128 (07): : 822 - 822
  • [44] A New In Vitro Bioassay System for the Discovery and Quantitative Evaluation of Mosquito Repellents
    Ali, Abbas
    Cantrell, Charles L.
    Khan, Ikhlas A.
    JOURNAL OF MEDICAL ENTOMOLOGY, 2017, 54 (05) : 1328 - 1336
  • [45] Statistical models for quantitative bioassay
    Facer, MR
    Müller, HG
    Clifford, AJ
    MATHEMATICAL MODELLING IN EXPERIMENTAL NUTRITION, 1998, 445 : 147 - 171
  • [46] ESTIMATING PARAMETERS IN QUANTITATIVE BIOASSAY
    ROSS, GJS
    BIOMETRICS, 1981, 37 (03) : 607 - 607
  • [47] Rapid quantitative bioassay of osteoinduction
    Adkisson, HD
    Strauss-Schoenberger, J
    Gillis, M
    Wilkins, R
    Jackson, M
    Hruska, KA
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2000, 18 (03) : 503 - 511
  • [48] QUANTITATIVE BIOASSAY OF FUNGICIDES IN THE LABORATORY
    HORSFALL, JG
    BOTANICAL REVIEW, 1945, 11 (07): : 357 - 397
  • [49] A QUANTITATIVE BIOASSAY SPECFIC FOR POLYGALACTURONASES
    MUSSELL, HW
    MORRE, DJ
    ANALYTICAL BIOCHEMISTRY, 1969, 28 (1-3) : 353 - &
  • [50] THE EFFECT OF TETRACYCLINES ON QUANTITATIVE MEASURES OF OSTEOCLAST MORPHOLOGY
    ZAIDI, M
    MOONGA, BS
    HUANG, CLH
    ALAM, ASMT
    SHANKAR, VS
    PAZIANAS, M
    EASTWOOD, JB
    DATTA, HK
    RIFKIN, BR
    BIOSCIENCE REPORTS, 1993, 13 (03) : 175 - 182