Morphological and elemental mapping of gallstones using synchrotron microtomography and synchrotron X-ray fluorescence spectroscopy

被引:6
|
作者
Bakthavatchalam, Mohana [1 ]
Venkataraman, Jayanthi [2 ]
Ramana, Ramya J. [1 ]
Jain, Mayank [2 ]
Singh, Balwant [4 ]
Thanigai, Arul K. [3 ]
Velyoudam, Vaithiswaran [2 ]
Neethirajan, Saravanan Manickam [2 ]
Tiwari, Manoj K. [4 ]
Agarwal, Ashish K. [4 ]
Kalkura, Narayana S. [1 ]
机构
[1] Anna Univ, Crystal Growth Ctr, Chennai 600025, Tamil Nadu, India
[2] Gleneagles Global Hosp & Hlth City, Inst GI Sci, Chennai, Tamil Nadu, India
[3] AMET, Dept Phys, Energy & Biophoton Lab, Chennai, Tamil Nadu, India
[4] Raja Ramanna Ctr Adv Technol, Indus 2, Indore, Madhya Pradesh, India
来源
JGH OPEN | 2019年 / 3卷 / 05期
关键词
cholesterol; elemental; gallstones; microtomography; pigment; synchroton; DISEASE; STONES; NORTH;
D O I
10.1002/jgh3.12171
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aim Regional differences in gallstone (GS) composition are well documented in the Indian subcontinent. The reasons for the same are unknown. Etiopathogenesis of GS remains elusive despite advances in instrumentation. This was an in-depth analysis of the chemical, structural, and elemental composition of GS with special reference to synchroton studies. Methods We used high-end sensitive analytical complementary microscopic and spectroscopic methods techniques, such as X-ray diffraction, scanning electron microscopy, Fourier transform infrared, synchrotron X-ray fluorescence spectroscopy (SR-XRF), and 2D and 3D synchrotron microtomography (SR-mu CT), to study the ultra structure and trace element composition of three major types of GS (cholesterol, mixed, and pigment). SR-XRF quantified the trace elements in GS. Results The cholesterol GS (monohydrate and anhydrate) were crystalline, with high calcium content. The pigment GS were amorphous, featureless, black, and fragile, with high calcium bilirubinate and carbonate salts. They had the highest concentration of iron (average 31.50 ppm) and copper (average 92.73 ppm), with bacterial inclusion. The mixed stones had features of both cholesterol and pigment GS with intermediate levels of copper (average 20.8 ppm) and iron (average 17.78 ppm). Conclusion SR-mu CT has, for the first time, provided cross-sectional computed imaging delineating the framework of GS and mineral distribution. It provided excellent mapping of cholesterol GS. SR-XRF confirmed that pigment GS had high concentrations of copper and iron with bacterial inclusions, the latter possibly serving as a nidus to the formation of these stones.
引用
下载
收藏
页码:381 / 387
页数:7
相关论文
共 50 条
  • [1] Mapping metal catalysts using synchrotron computed microtomography and micro X-ray fluorescence.
    Jones, KW
    Feng, H
    Mahajan, D
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 226 : U569 - U569
  • [2] Elemental Imaging in Biology Using Synchrotron X-Ray Fluorescence Microscopy
    Brown, Koshonna
    Paunesku, Tatjana
    Woloschak, Gayle E.
    BIOMARKERS OF RADIATION IN THE ENVIRONMENT: ROBUST TOOLS FOR RISK ASSESSMENT, 2022, : 37 - 52
  • [3] High-resolution elemental mapping of human placental chorionic villi using synchrotron X-ray fluorescence spectroscopy
    Punshon, Tracy
    Chen, Si
    Finney, Lydia
    Howard, Louisa
    Jackson, Brian P.
    Karagas, Margaret R.
    Ornvold, Kim
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (22) : 6839 - 6850
  • [4] High-resolution elemental mapping of human placental chorionic villi using synchrotron X-ray fluorescence spectroscopy
    Tracy Punshon
    Si Chen
    Lydia Finney
    Louisa Howard
    Brian P. Jackson
    Margaret R. Karagas
    Kim Ornvold
    Analytical and Bioanalytical Chemistry, 2015, 407 : 6839 - 6850
  • [5] X-ray diffraction microtomography using synchrotron radiation
    Barroso, RC
    Lopes, RT
    de Jesus, EFO
    Oliveira, LF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 471 (1-2): : 75 - 79
  • [6] USING SYNCHROTRON X-RAY MICROTOMOGRAPHY TO DETECT DEFECTS
    MILEWSKI, JO
    HMELO, AB
    DAMICO, KL
    DUNSMUIR, JH
    FERGUSON, SR
    WELDING JOURNAL, 1994, 73 (02) : 45 - 49
  • [7] X-ray transmission microtomography using synchrotron radiation
    Lopes, RT
    Rocha, HS
    de Jesus, EFO
    Barroso, RC
    de Oliveira, LF
    Anjos, MJ
    Braz, D
    Moreira, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2): : 604 - 607
  • [8] X-ray fluorescence microtomography and polycapillary based confocal imaging using synchrotron radiation
    Vincze, L
    Vekemans, B
    Szalóki, I
    Brenker, FE
    Falkenberg, G
    Rickers, K
    Aerts, K
    Van Grieken, R
    Adams, F
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IV, 2004, 5535 : 220 - 231
  • [9] Three-dimensional strain mapping using in situ X-ray synchrotron microtomography
    Toda, H.
    Maire, E.
    Aoki, Y.
    Kobayashi, M.
    JOURNAL OF STRAIN ANALYSIS FOR ENGINEERING DESIGN, 2011, 46 (07): : 549 - 561
  • [10] X-RAY MICROTOMOGRAPHY WITH MONOCHROMATIC SYNCHROTRON RADIATION
    DAMICO, KL
    DECKMAN, HW
    DUNSMUIR, JH
    FLANNERY, BP
    ROBERGE, WG
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 1524 - 1526