The ClearPET™ project:: development of a 2nd generation high-performance small animal PET scanner

被引:107
|
作者
Ziemons, K [1 ]
Auffray, E
Barbier, R
Brandenburg, G
Bruyndonckx, P
Choi, Y
Christ, D
Costes, N
Declais, Y
Devroede, O
Dujardin, C
Fedorovd, A
Heinrichs, U
Korjik, M
Krieguer, M
Kuntner, C
Largeron, G
Lartizien, C
Larue, H
Lecoq, P
Leonard, S
Marteau, J
Morel, C
Mosset, JB
Parl, C
Pedrini, C
Petrosyan, AG
Pietrzyk, U
Rey, M
Saladino, S
Sappey-Marinier, D
Simon, L
Streun, M
Tavernier, S
Vieira, JM
机构
[1] Forschungszentrum Julich, D-52425 Julich, Germany
[2] CERN, CH-1211 Geneva 23, Switzerland
[3] Univ Lyon 1, F-69003 Lyon, France
[4] Free Univ Brussels, B-1050 Brussels, Belgium
[5] Sungkyunkwan Univ, Samsung Med Ctr, Seoul 135710, South Korea
[6] Inst Nucl Problems, Minsk 220050, BELARUS
[7] Univ Lausanne, CH-1015 Lausanne, Switzerland
[8] Armenian Acad Sci, Inst Phys Res, Ashtarak 378410, Armenia
关键词
positron emission tomography; small animal PET; depth of interaction; dual layer phoswich system;
D O I
10.1016/j.nima.2004.08.032
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Second generation high-performance PET scanners, called ClearPET(TM)(1), have been developed by working groups of the Crystal Clear Collaboration (CCC). High sensitivity and hi.-h spatial resolution for the ClearPET camera is achieved by using a phoswich arrangement combining two different types of lutetium-based scintillator materials: LSO from CTI and LuYAP:Ce from the CCC (ISTC project). In a first ClearPET prototype, phoswich arrangements of 8 x 8 crystals of 2 x 2 x 10 mm(3) are coupled to multi-channel photomultiplier tubes (Hamamatsu R7600). A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the ring is 120 mm, the axial detector length is 110 mm. The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the exact pulse starting time. which is subsequently used for coincidence detection. The gantry allows rotation of the detector modules around the field of view.
引用
收藏
页码:307 / 311
页数:5
相关论文
共 50 条
  • [1] Raytest ClearPET™, a new generation small animal PET scanner
    Roldan, P. Sempere
    Chereul, E.
    Dietzel, O.
    Magnier, L.
    Pautrot, C.
    Rbah, L.
    Sappey-Marinier, D.
    Wagner, A.
    Zimmer, L.
    Janier, M.
    Tarazona, V.
    Dietzel, G.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2): : 498 - 501
  • [2] The ClearPET™ LSO/LuYAP phoswich scanner:: A high performance small animal PET system
    Ziemons, K
    Auffray, E
    Barbier, R
    Brandenburg, G
    Bruyndonckx, P
    Choi, Y
    Christ, D
    Costes, N
    Declais, Y
    Devroede, O
    Dujardin, C
    Fedorov, AA
    Heinrichs, U
    Hollendung, A
    Korjhik, MJ
    Krieguer, M
    Kuntner, C
    Largeron, G
    Lartizien, C
    Larue, H
    Lecoq, P
    Leonard, S
    Marteau, J
    Morel, C
    Mosset, JB
    Parl, C
    Pedrini, C
    Petrosyan, AG
    Pietrzyk, U
    Rey, M
    Saladino, S
    Sappey-Marinier, D
    Simon, L
    Streun, M
    Tavernier, S
    Vieira, JM
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1728 - 1732
  • [3] Design and construction of the ClearPET/XPAD small animal PET/CT scanner
    Nicol, S.
    Karkar, S.
    Hemmer, C.
    Dawiec, A.
    Benoit, D.
    Breugnon, P.
    Dinkespiler, B.
    Riviere, F.
    Logier, J. -P.
    Niclas, M.
    Royon, J.
    Meessen, C.
    Cassol, F.
    Clemens, J. -C.
    Bonissent, A.
    Debarbieux, F.
    Vigeolas, E.
    Delpierre, P.
    Morel, C.
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3311 - 3314
  • [4] The data acquisition system of ClearPET neuro - a small animal PET scanner
    Streun, M
    Brandenburg, G
    Larue, H
    Parl, C
    Ziemons, K
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) : 700 - 703
  • [5] Design study for the ClearPET/XPAD small animal PET/CT scanner
    Khodaverdi, M.
    Nicol, S.
    Loess, J.
    Brunner, F. Cassol
    Karkar, S.
    Morel, C.
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4300 - 4302
  • [6] The ClearPET™ neuro scanner:: A dedicated LSO/LuYAP phoswich small animal PET scanner
    Ziemons, K
    Achten, R
    Auffray, E
    Bauer, A
    Brandenburg, G
    Bruyndonckx, P
    Choi, Y
    Daemen, J
    Dehnhardt, M
    Devroede, O
    Fleischer, M
    Fuss, L
    Heinrichs, U
    Hollendung, A
    Holschbach, M
    Khodaverdi, M
    Kirchner, P
    Kleines, H
    Krieguer, M
    Larue, H
    Lecoq, P
    Leyendecker, M
    Moeller, R
    Morel, C
    Mosset, JB
    Parl, C
    Pietrzyk, U
    Schmitz, J
    Streun, M
    Tavernier, S
    Veggian, M
    Zimmermann, E
    Coenen, HH
    Halling, H
    Sievering, R
    Zilles, K
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2430 - 2433
  • [7] The ClearPET™:: A high resolution high sensitivity dual-layer phoswich small animal PET scanner
    Heinrichs, U
    Bruyndonckx, P
    Choi, Y
    Dietzel, G
    Korjik, M
    Lecoq, P
    Morel, C
    Pedrini, C
    Petrosyan, AG
    Pietrzyk, U
    Sappey-Marinier, D
    Streun, M
    Tavernier, S
    Ziemons, K
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S400 - S400
  • [8] Performance evaluation of raytest ClearPET™ a PET scanner for small and medium size animals
    Roldan, P. Sernpere
    Canadas, M.
    Dietzel, O.
    Pautrot, C.
    Sarasola, I.
    Wagner, A.
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2859 - +
  • [9] A High-Sensitivity Small-Animal PET Scanner: Development and Initial Performance Measurements
    Kao, Chien-Min
    Xie, Qingguo
    Dong, Yun
    Wan, Lu
    Chen, Chin-Tu
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (05) : 2678 - 2688
  • [10] Performance characterization of a high-sensitivity small-animal PET scanner
    Kao, Chien-Min
    Xie, Qingguo
    Dong, Yun
    Wan, Lu
    Chen, Chin-Tu
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4176 - +