The data acquisition system of ClearPET neuro - a small animal PET scanner

被引:54
|
作者
Streun, M [1 ]
Brandenburg, G [1 ]
Larue, H [1 ]
Parl, C [1 ]
Ziemons, K [1 ]
机构
[1] Forschungszentrum Julich, Zent Inst Elekt, D-52425 Julich, Germany
关键词
free-running pulse sampling; LSO; LuYAP; multichannel photomultiplier; positron emission tomography;
D O I
10.1109/TNS.2006.875051
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The Crystal Clear Collaboration has developed a modular system for a small animal PET scanner (ClearPET). The modularity allows the assembly of scanners of different sizes and characteristics in order to satisfy the specific needs of the individual member institutions. The system performs depth of interaction detection by using a phoswich arrangement combining LSO and LuYAP scintillators which are coupled to Multichannel Photomultipliers (PMTs). For each PMT a free running 40 MHz ADC digitizes the signal and the complete scintillation pulse is sampled by an FPGA and sent with 20 MB/s to a PC for preprocessing. The pulse provides information about the gamma energy and the scintillator material which identifies the interaction layer. Furthermore, the exact pulse starting time is obtained from the sampled data. This is important as no hardware coincidence detection is implemented. All single events are recorded and coincidences are identified by software. The system in Jiilich (ClearPET Neuro) is equipped with 10140 crystals on 80 PMTs. The paper will present an overview of the data acquisition system.
引用
收藏
页码:700 / 703
页数:4
相关论文
共 50 条
  • [1] The ClearPET™ neuro scanner:: A dedicated LSO/LuYAP phoswich small animal PET scanner
    Ziemons, K
    Achten, R
    Auffray, E
    Bauer, A
    Brandenburg, G
    Bruyndonckx, P
    Choi, Y
    Daemen, J
    Dehnhardt, M
    Devroede, O
    Fleischer, M
    Fuss, L
    Heinrichs, U
    Hollendung, A
    Holschbach, M
    Khodaverdi, M
    Kirchner, P
    Kleines, H
    Krieguer, M
    Larue, H
    Lecoq, P
    Leyendecker, M
    Moeller, R
    Morel, C
    Mosset, JB
    Parl, C
    Pietrzyk, U
    Schmitz, J
    Streun, M
    Tavernier, S
    Veggian, M
    Zimmermann, E
    Coenen, HH
    Halling, H
    Sievering, R
    Zilles, K
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2430 - 2433
  • [2] Development of a data acquisition system for the MiCES small animal PET scanner
    Lewellen, TK
    Laymon, CM
    Miyaoka, RS
    Janes, M
    Park, B
    Lee, K
    Kinahan, PE
    [J]. 2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1066 - 1070
  • [3] Raytest ClearPET™, a new generation small animal PET scanner
    Roldan, P. Sempere
    Chereul, E.
    Dietzel, O.
    Magnier, L.
    Pautrot, C.
    Rbah, L.
    Sappey-Marinier, D.
    Wagner, A.
    Zimmer, L.
    Janier, M.
    Tarazona, V.
    Dietzel, G.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2): : 498 - 501
  • [4] The ClearPET™ LSO/LuYAP phoswich scanner:: A high performance small animal PET system
    Ziemons, K
    Auffray, E
    Barbier, R
    Brandenburg, G
    Bruyndonckx, P
    Choi, Y
    Christ, D
    Costes, N
    Declais, Y
    Devroede, O
    Dujardin, C
    Fedorov, AA
    Heinrichs, U
    Hollendung, A
    Korjhik, MJ
    Krieguer, M
    Kuntner, C
    Largeron, G
    Lartizien, C
    Larue, H
    Lecoq, P
    Leonard, S
    Marteau, J
    Morel, C
    Mosset, JB
    Parl, C
    Pedrini, C
    Petrosyan, AG
    Pietrzyk, U
    Rey, M
    Saladino, S
    Sappey-Marinier, D
    Simon, L
    Streun, M
    Tavernier, S
    Vieira, JM
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1728 - 1732
  • [5] Firmware Upgrade for the Data Acquisition System of the LabPET™ Small Animal PET Scanner
    Tetrault, M. -A.
    Bergeron, M.
    Lecomte, R.
    Fontaine, R.
    [J]. 2009 16TH IEEE-NPSS REAL TIME CONFERENCE, 2009, : 244 - +
  • [6] Firmware Upgrade for the Data Acquisition System of the LabPET Small Animal PET Scanner
    Tetrault, M. -A.
    Bergeron, M.
    Lecomte, R.
    Fontaine, R.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (02) : 556 - 560
  • [7] Design and construction of the ClearPET/XPAD small animal PET/CT scanner
    Nicol, S.
    Karkar, S.
    Hemmer, C.
    Dawiec, A.
    Benoit, D.
    Breugnon, P.
    Dinkespiler, B.
    Riviere, F.
    Logier, J. -P.
    Niclas, M.
    Royon, J.
    Meessen, C.
    Cassol, F.
    Clemens, J. -C.
    Bonissent, A.
    Debarbieux, F.
    Vigeolas, E.
    Delpierre, P.
    Morel, C.
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3311 - 3314
  • [8] Design study for the ClearPET/XPAD small animal PET/CT scanner
    Khodaverdi, M.
    Nicol, S.
    Loess, J.
    Brunner, F. Cassol
    Karkar, S.
    Morel, C.
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4300 - 4302
  • [9] The ClearPET™:: A high resolution high sensitivity dual-layer phoswich small animal PET scanner
    Heinrichs, U
    Bruyndonckx, P
    Choi, Y
    Dietzel, G
    Korjik, M
    Lecoq, P
    Morel, C
    Pedrini, C
    Petrosyan, AG
    Pietrzyk, U
    Sappey-Marinier, D
    Streun, M
    Tavernier, S
    Ziemons, K
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S400 - S400
  • [10] First results with the clearpet small animal PET scanners
    Auffray, E.
    Boutemeur, M.
    Brandenburg, G.
    Bruyndonckx, P.
    Choi, Y.
    D'Asseler, Y.
    Devroede, O.
    Dietzel, O.
    Dujardin, C.
    Fedorov, A.
    Janier, M.
    Jung, J. H.
    Khodaverdi, M.
    Korjik, M.
    Krieguer, M.
    Lartizien, C.
    Larue, H.
    Lecoq, P.
    Lemaitre, C.
    Loude, J. -F.
    Morel, C.
    Mosset, J. -B.
    Parl, C.
    Pautrot, C.
    Ptdrinie, C.
    Petrosyan, A. G.
    Pietrzyk, U.
    Rey, M.
    Sappey-Marinier, D.
    Roldan, P. Sempere
    Song, T. Y.
    Staelens, S.
    Streun, M.
    Tavernier, S.
    Trummer, J.
    Vandenberghe, S.
    Van Holen, R.
    Vieira, J. -M.
    Weber, S.
    Wieers, W.
    Wisniewska, M.
    Wisniewski, D.
    Wu, Y.
    Ziemons, K.
    [J]. RADIATION DETECTORS FOR MEDICAL APPLICATIONS, 2006, : 149 - +