Algorithm for hyperfast cone-beam spiral backprojection

被引:4
|
作者
Steckmann, Sven [1 ]
Knaup, Michael [1 ]
Kachelriess, Marc [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, D-91052 Erlangen, Germany
关键词
CT; Image reconstruction; Backprojection; Spiral CT; High performance computing; HELICAL CT; IMAGE-RECONSTRUCTION; SCHEME;
D O I
10.1016/j.cmpb.2009.08.003
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Cone-beam spiral backprojection is computationally highly demanding. At first sight, the backprojection requirements are similar to those of cone-beam backprojection from circular scans such as it is performed in the widely used Feldkamp algorithm. However, there is an additional complication: the illumination of each voxel, i.e. the range of angles the voxel is seen by the X-ray cone is a complex function of the voxel position. The weight function has no analytically closed form and must be numerically determined. Storage of the weights is prohibitive since the amount of memory required equals the number of voxels per spiral rotation times the number of projections a voxel receives contributions and therefore is in the order of 10(9) to 10(11) floating point values for typical spiral scans. We propose a new algorithm that combines the spiral symmetry with the ability of today's 64 bit CPUs to store large amounts of precomputed weights. Using the spiral symmetry in this way allows to exploit data-level parallelism and thereby to achieve a very high level of vectorization. An additional postprocessing step rotates these slices back to normal images. Our new backprojection algorithm achieves up to 24.6 Giga voxel updates per second (GUPS) on our systems that are equipped with two standard Intel X5570 quad core CPUs (Intel Xeon 5500 platform, 2.93 GHz, Intel Corporation). This equals the reconstruction of 410 images per second assuming each slice consists of 512 x 512 pixels, receiving contributions from 512 projections. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:253 / 260
页数:8
相关论文
共 50 条
  • [21] Fast hierarchical backprojection for helical cone-beam tomography
    Bresler, Y
    Brokish, J
    [J]. 2003 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOL 2, PROCEEDINGS, 2003, : 815 - 818
  • [22] Cone beam cover method: An approach to performing backprojection in Katsevich's exact algorithm for spiral cone beam CT
    Yang, Jiansheng
    Kong, Qiang
    Zhou, Tie
    Jiang, Ming
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2004, 12 (04) : 199 - 214
  • [23] New approximate filtered backprojection algorithm for helical cone-beam CT with redundant data
    Kudo, H
    Noo, F
    Defrise, M
    Rodet, T
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3211 - 3215
  • [24] A rebinned backprojection-filtration algorithm for image reconstruction in helical cone-beam CT
    Yu, Lifeng
    Xia, Dan
    Zou, Yu
    Sidky, Emil Y.
    Bian, Junguo
    Pan, Xiaochuan
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (18): : 5497 - 5508
  • [25] Backprojection implementation of the local ROI technique for solving the long object problem in spiral cone-beam CT
    Tam, Kwok
    Lauritsch, Guenter
    Sourbellec, Katia
    [J]. Annals of Biomedical Engineering, 2000, 28 (SUPPL. 1)
  • [26] Performance evaluation of the backprojection filtered (BPF) algorithm in circular fan-beam and cone-beam CT
    LI Liang CHEN Zhi-Qiang ZHANG Li KANG Ke-Jun Department of Engineering Physics
    [J]. Nuclear Science and Techniques, 2006, (02) : 113 - 117
  • [27] Cone-beam reconstruction using the backprojection of locally filtered projections
    Pack, JD
    Noo, F
    Clackdoyle, R
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (01) : 70 - 85
  • [28] Implementation of a fast cone-beam backprojection algorithm for microcomputed tomography (HCT) using homogeneous coordinates
    Schaller, S
    Karolczak, M
    Engelke, K
    Wiesent, K
    Kalender, WA
    [J]. RADIOLOGY, 1998, 209P : 433 - 434
  • [29] Parallel Backprojection-Filtration Algorithm for 3D Helical Cone-Beam CT
    Liu, Baodong
    Zeng, Li
    Zou, Xiaobing
    [J]. 2010 6TH INTERNATIONAL CONFERENCE ON WIRELESS COMMUNICATIONS NETWORKING AND MOBILE COMPUTING (WICOM), 2010,
  • [30] Exact local regions-of-interest reconstruction in spiral cone-beam filtered-backprojection CT: theory
    Tam, KC